Ultra-Low Plasma Freezer
超低温血浆冷冻柜
- SKU PLF-0004
- Plasma Freezers
- CE (to be confirmed)
- ISO 13485 (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | –60 °C to –86 °C |
|---|---|
| Net capacity | 100–700 L |
| Refrigeration | Cascade, two compressors |
| Uniformity | ≤ ±5 °C |
| Pull-down time | approx. 4–6 h to –80 °C (empty) |
| Warm-up time (full, power off) | approx. 8–14 h to –50 °C |
By Lab Manufacturers China Technical TeamLast reviewed Standards: Council of Europe Guide to the Preparation, Use and Quality Assurance of Blood Components, AABB Standards for Blood Banks and Transfusion Services, IEC 61010-2-011
What is the Ultra-Low Plasma Freezer?
An ultra-low plasma freezer maintains –60 °C to –86 °C for extended storage of plasma, cryoprecipitate and research plasma collections. It is used where regulations permit longer shelf life at –65 °C or below, or where sample integrity must be preserved for years.
What is the Ultra-Low Plasma Freezer?
An ultra-low plasma freezer maintains –60 °C to –86 °C for extended storage of plasma, cryoprecipitate and research plasma collections. It is used where regulations permit longer shelf life at –65 °C or below, or where sample integrity must be preserved for years.
Overview
Ultra-low freezers usually use a cascade refrigeration system with two compressors and a heat exchanger, reaching –80 °C to –86 °C. Thick vacuum or polyurethane insulation and multiple inner doors limit heat gain. Capacities typically run from 100 to 700 L, with racks and drawers for boxes or cartons. The controller holds –80 °C or –70 °C setpoints and includes independent alarms, battery backup and optional CO2 or LN2 backup. Recovery after door opening is slower than –30 °C units, so access should be planned. Energy use is higher, so heat load and ambient temperature need attention. The deeper temperature slows enzyme activity and extends stability, making it a fit for archiving and plasma used in diagnostic reagent production.
How does it work?
Plasma freezers use a compressor refrigeration circuit, often a single-stage system with low-temperature refrigerant for –40 °C models and a cascade system for –80 °C models. Air circulates past plates or shelves to extract heat, and heavy polyurethane insulation limits gain. Quality depends on how fast plasma passes through its freezing range: coagulation factors such as Factor VIII are better preserved when the core reaches –30 °C within about one hour, so rapid freezers use high airflow or contact plates. A controller reads an RTD probe, often in a glycol buffer, and drives independent alarms and a recorder. Door gaskets with heaters prevent icing, and condenser fans and a backup CO2 or LN2 option can protect stock during power loss.
What are the key features?
- Cascade refrigeration reaches –60 °C to –86 °C
- Multiple inner doors limit cold loss during access
- Independent alarm probe with battery backup
- Optional CO2 or LN2 backup for power failure
- Racks and drawers for boxes or cartons
- Electronic recorder with network output
What are the technical specifications?
A typical ultra-low plasma freezer configuration offers temperature range of –60 °C to –86 °C, net capacity of 100–700 L, refrigeration of Cascade, two compressors, uniformity of ≤ ±5 °C, pull-down time of approx. 4–6 h to –80 °C (empty) and warm-up time (full, power off) of approx. 8–14 h to –50 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Ultra-Low Plasma Freezer is used in long-term plasma archiving, diagnostic reagent plasma, research plasma biobanking and rare plasma inventory. Across the wider Plasma Freezers class, laboratories also deploy it for fresh frozen plasma storage, cryoprecipitate storage and plasma for fractionation.
Which standards and certifications apply?
Relevant standards and methods include Council of Europe Guide to the Preparation, Use and Quality Assurance of Blood Components, AABB Standards for Blood Banks and Transfusion Services, IEC 61010-2-011, IEC 61010-1, IEC 61326-1 and ISO 13485. Certification candidates for this model are CE, ISO 13485 and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the freezer on a level floor with clear ventilation and a dedicated circuit. Run it empty until stable and map temperature before loading. Handle frozen plasma carefully to avoid bag cracks, and store in overwrap or cartons. Calibrate probes at least annually, test alarms regularly, and defrost or clean according to the maker's schedule to control frost. Keep records for the regulatory period and maintain a contingency plan that names a validated alternate freezer or dry-ice supply. Do not load large warm volumes at once, since this raises the chamber temperature and stresses the compressor.
How do I select the right Ultra-Low Plasma Freezer?
Select ultra-low storage when your rules grant longer shelf life below –65 °C or samples must be retained for years. Specify capacity, inner door count, backup type, alarm outputs and ambient class. For routine clinical plasma at –30 °C, standard plasma freezers use less energy.
How does it compare with other Plasma Freezers variants?
Decide first whether you need freezing, storage or both. Blast models freeze plasma quickly and are usually followed by storage units. For storage, choose the temperature by the shelf life your regulator allows: storage at –25 °C or colder is commonly accepted for up to 36 months in European guidance, while –65 °C or colder extends shelf life under some standards. Then pick upright or chest format by floor space and access frequency, capacity in bags or liters, and monitoring needs. Check the recovery time after door opening, noise, ambient class and whether a CO2 or LN2 backup port is offered. Plan for electrical supply and heat load in the room.
Full specifications
| Temperature range | –60 °C to –86 °C |
|---|---|
| Net capacity | 100–700 L |
| Refrigeration | Cascade, two compressors |
| Uniformity | ≤ ±5 °C |
| Pull-down time | approx. 4–6 h to –80 °C (empty) |
| Warm-up time (full, power off) | approx. 8–14 h to –50 °C |
| Inner doors | 2–4 |
| Alarms | High/low, door, power, sensor, battery |
| Ambient range | 15–32 °C |
| Power supply | 220 V, 50 Hz, 6–10 A |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Long-term plasma archiving
- Diagnostic reagent plasma
- Research plasma biobanking
- Rare plasma inventory
Key features
- Cascade refrigeration reaches –60 °C to –86 °C
- Multiple inner doors limit cold loss during access
- Independent alarm probe with battery backup
- Optional CO2 or LN2 backup for power failure
- Racks and drawers for boxes or cartons
- Electronic recorder with network output
Frequently asked questions about Ultra-Low Plasma Freezer
It is used when regulations grant longer shelf life below –65 °C, when plasma is kept as reagent or research material, or when long-term archiving is planned. Routine clinical fresh frozen plasma is usually kept at –25 °C to –40 °C.
Yes. Cascade systems consume more electricity, typically several kWh per day for mid-size units, and they reject more heat to the room. Account for ventilation and ambient temperature, and keep condenser filters clean to protect efficiency.
Recovery after a short opening usually takes 15–60 minutes depending on load and ambient temperature, slower than higher-temperature units. Using inner doors, limiting open time and pre-staging needed items reduce excursions.
Fresh frozen plasma is commonly stored at –25 °C or colder, with many sites using –30 °C to –40 °C. Some standards allow –18 °C to –25 °C for shorter periods, and –65 °C or colder for extended shelf life. Always follow your regulator and verify the product shelf life table.
Labile coagulation factors, notably Factor VIII, degrade more when plasma stays in the freezing range for long. Freezing the core to –30 °C within about one hour, often with blast air or contact plates, retains more activity, and guidelines define the time allowed from collection to freezing.
Plasma freezers carry independent alarm and recorder probes, tighter uniformity, battery-backed alarms and racking for blood bags, and are validated for transfusion-related storage. Laboratory freezers often lack these features and are not designed for storing components intended for patients.