Ultra-Low Plasma Freezer

超低温血浆冷冻柜

  • SKU PLF-0004
  • Plasma Freezers
  • CE (to be confirmed)
  • ISO 13485 (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Temperature range–60 °C to –86 °C
Net capacity100–700 L
RefrigerationCascade, two compressors
Uniformity≤ ±5 °C
Pull-down timeapprox. 4–6 h to –80 °C (empty)
Warm-up time (full, power off)approx. 8–14 h to –50 °C
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: Council of Europe Guide to the Preparation, Use and Quality Assurance of Blood Components, AABB Standards for Blood Banks and Transfusion Services, IEC 61010-2-011

What is the Ultra-Low Plasma Freezer?

An ultra-low plasma freezer maintains –60 °C to –86 °C for extended storage of plasma, cryoprecipitate and research plasma collections. It is used where regulations permit longer shelf life at –65 °C or below, or where sample integrity must be preserved for years.

What is the Ultra-Low Plasma Freezer?

An ultra-low plasma freezer maintains –60 °C to –86 °C for extended storage of plasma, cryoprecipitate and research plasma collections. It is used where regulations permit longer shelf life at –65 °C or below, or where sample integrity must be preserved for years.

Overview

Ultra-low freezers usually use a cascade refrigeration system with two compressors and a heat exchanger, reaching –80 °C to –86 °C. Thick vacuum or polyurethane insulation and multiple inner doors limit heat gain. Capacities typically run from 100 to 700 L, with racks and drawers for boxes or cartons. The controller holds –80 °C or –70 °C setpoints and includes independent alarms, battery backup and optional CO2 or LN2 backup. Recovery after door opening is slower than –30 °C units, so access should be planned. Energy use is higher, so heat load and ambient temperature need attention. The deeper temperature slows enzyme activity and extends stability, making it a fit for archiving and plasma used in diagnostic reagent production.

How does it work?

Plasma freezers use a compressor refrigeration circuit, often a single-stage system with low-temperature refrigerant for –40 °C models and a cascade system for –80 °C models. Air circulates past plates or shelves to extract heat, and heavy polyurethane insulation limits gain. Quality depends on how fast plasma passes through its freezing range: coagulation factors such as Factor VIII are better preserved when the core reaches –30 °C within about one hour, so rapid freezers use high airflow or contact plates. A controller reads an RTD probe, often in a glycol buffer, and drives independent alarms and a recorder. Door gaskets with heaters prevent icing, and condenser fans and a backup CO2 or LN2 option can protect stock during power loss.

What are the key features?

  • Cascade refrigeration reaches –60 °C to –86 °C
  • Multiple inner doors limit cold loss during access
  • Independent alarm probe with battery backup
  • Optional CO2 or LN2 backup for power failure
  • Racks and drawers for boxes or cartons
  • Electronic recorder with network output

What are the technical specifications?

A typical ultra-low plasma freezer configuration offers temperature range of –60 °C to –86 °C, net capacity of 100–700 L, refrigeration of Cascade, two compressors, uniformity of ≤ ±5 °C, pull-down time of approx. 4–6 h to –80 °C (empty) and warm-up time (full, power off) of approx. 8–14 h to –50 °C. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Ultra-Low Plasma Freezer is used in long-term plasma archiving, diagnostic reagent plasma, research plasma biobanking and rare plasma inventory. Across the wider Plasma Freezers class, laboratories also deploy it for fresh frozen plasma storage, cryoprecipitate storage and plasma for fractionation.

Which standards and certifications apply?

Relevant standards and methods include Council of Europe Guide to the Preparation, Use and Quality Assurance of Blood Components, AABB Standards for Blood Banks and Transfusion Services, IEC 61010-2-011, IEC 61010-1, IEC 61326-1 and ISO 13485. Certification candidates for this model are CE, ISO 13485 and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the freezer on a level floor with clear ventilation and a dedicated circuit. Run it empty until stable and map temperature before loading. Handle frozen plasma carefully to avoid bag cracks, and store in overwrap or cartons. Calibrate probes at least annually, test alarms regularly, and defrost or clean according to the maker's schedule to control frost. Keep records for the regulatory period and maintain a contingency plan that names a validated alternate freezer or dry-ice supply. Do not load large warm volumes at once, since this raises the chamber temperature and stresses the compressor.

How do I select the right Ultra-Low Plasma Freezer?

Select ultra-low storage when your rules grant longer shelf life below –65 °C or samples must be retained for years. Specify capacity, inner door count, backup type, alarm outputs and ambient class. For routine clinical plasma at –30 °C, standard plasma freezers use less energy.

How does it compare with other Plasma Freezers variants?

Decide first whether you need freezing, storage or both. Blast models freeze plasma quickly and are usually followed by storage units. For storage, choose the temperature by the shelf life your regulator allows: storage at –25 °C or colder is commonly accepted for up to 36 months in European guidance, while –65 °C or colder extends shelf life under some standards. Then pick upright or chest format by floor space and access frequency, capacity in bags or liters, and monitoring needs. Check the recovery time after door opening, noise, ambient class and whether a CO2 or LN2 backup port is offered. Plan for electrical supply and heat load in the room.

Full specifications

Full specifications
Temperature range–60 °C to –86 °C
Net capacity100–700 L
RefrigerationCascade, two compressors
Uniformity≤ ±5 °C
Pull-down timeapprox. 4–6 h to –80 °C (empty)
Warm-up time (full, power off)approx. 8–14 h to –50 °C
Inner doors2–4
AlarmsHigh/low, door, power, sensor, battery
Ambient range15–32 °C
Power supply220 V, 50 Hz, 6–10 A

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Long-term plasma archiving
  • Diagnostic reagent plasma
  • Research plasma biobanking
  • Rare plasma inventory

Key features

  • Cascade refrigeration reaches –60 °C to –86 °C
  • Multiple inner doors limit cold loss during access
  • Independent alarm probe with battery backup
  • Optional CO2 or LN2 backup for power failure
  • Racks and drawers for boxes or cartons
  • Electronic recorder with network output

Frequently asked questions about Ultra-Low Plasma Freezer

It is used when regulations grant longer shelf life below –65 °C, when plasma is kept as reagent or research material, or when long-term archiving is planned. Routine clinical fresh frozen plasma is usually kept at –25 °C to –40 °C.