Undercounter Plasma Freezer
台下式血浆冷冻柜
- SKU PLF-0005
- Plasma Freezers
- CE (to be confirmed)
- ISO 13485 (to be confirmed)
- RoHS (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | –25 °C to –40 °C |
|---|---|
| Net capacity | 80–200 L |
| Plasma unit capacity | approx. 40–120 units (250 mL) |
| Dimensions (W×D×H) | 600 × 650 × 830 mm |
| Uniformity | ≤ ±3 °C |
| Refrigerant | R290 or R404A (region dependent) |
By Lab Manufacturers China Technical TeamLast reviewed Standards: Council of Europe Guide to the Preparation, Use and Quality Assurance of Blood Components, AABB Standards for Blood Banks and Transfusion Services, IEC 61010-2-011
What is the Undercounter Plasma Freezer?
An undercounter plasma freezer is a compact –30 °C to –40 °C unit, typically 80–200 L, that fits below a bench. It suits small hospital blood banks, satellite transfusion points and laboratories holding a small plasma stock with alarms and recording.
What is the Undercounter Plasma Freezer?
An undercounter plasma freezer is a compact –30 °C to –40 °C unit, typically 80–200 L, that fits below a bench. It suits small hospital blood banks, satellite transfusion points and laboratories holding a small plasma stock with alarms and recording.
Overview
The undercounter format places ventilation at the front and sits beneath a standard worktop. Capacity is limited, typically holding 40 to 120 plasma units in drawers, so it serves small or backup stocks. Temperatures of –30 °C to –40 °C are held by a microprocessor controller and an independent alarm probe, with door-open and power-failure alarms and optional recorder. Because the chamber is small, frost and temperature swings can build quickly if door opening is frequent, so limited access and good stock management are needed. The small size also gives a shorter hold-over during outages than chest or large upright units. It is useful as a dedicated contingency freezer for transferring stock if a main unit fails.
How does it work?
Plasma freezers use a compressor refrigeration circuit, often a single-stage system with low-temperature refrigerant for –40 °C models and a cascade system for –80 °C models. Air circulates past plates or shelves to extract heat, and heavy polyurethane insulation limits gain. Quality depends on how fast plasma passes through its freezing range: coagulation factors such as Factor VIII are better preserved when the core reaches –30 °C within about one hour, so rapid freezers use high airflow or contact plates. A controller reads an RTD probe, often in a glycol buffer, and drives independent alarms and a recorder. Door gaskets with heaters prevent icing, and condenser fans and a backup CO2 or LN2 option can protect stock during power loss.
What are the key features?
- Front-ventilated design fits below worktops
- Holds –30 °C to –40 °C in 80–200 L
- Drawers for labeled plasma units
- Independent alarm probe and power-failure alarm
- Lockable door to control access
- Optional data recorder and remote alarm contacts
What are the technical specifications?
A typical undercounter plasma freezer configuration offers temperature range of –25 °C to –40 °C, net capacity of 80–200 L, plasma unit capacity of approx. 40–120 units (250 mL), dimensions (W×D×H) of 600 × 650 × 830 mm, uniformity of ≤ ±3 °C and refrigerant of R290 or R404A (region dependent). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Undercounter Plasma Freezer is used in small hospital blood banks, satellite transfusion points, contingency freezer for main storage and clinical research plasma. Across the wider Plasma Freezers class, laboratories also deploy it for fresh frozen plasma storage, cryoprecipitate storage and plasma for fractionation.
Which standards and certifications apply?
Relevant standards and methods include Council of Europe Guide to the Preparation, Use and Quality Assurance of Blood Components, AABB Standards for Blood Banks and Transfusion Services, IEC 61010-2-011, IEC 61010-1, IEC 61326-1 and ISO 13485. Certification candidates for this model are CE, ISO 13485 and RoHS; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the freezer on a level floor with clear ventilation and a dedicated circuit. Run it empty until stable and map temperature before loading. Handle frozen plasma carefully to avoid bag cracks, and store in overwrap or cartons. Calibrate probes at least annually, test alarms regularly, and defrost or clean according to the maker's schedule to control frost. Keep records for the regulatory period and maintain a contingency plan that names a validated alternate freezer or dry-ice supply. Do not load large warm volumes at once, since this raises the chamber temperature and stresses the compressor.
How do I select the right Undercounter Plasma Freezer?
Pick an undercounter freezer for small stocks under about 100 units or as a contingency unit. Specify height limit, drawer count, door hinge side, alarm outputs and recorder. For larger or long-term stock, use an upright or chest freezer, and keep a written transfer plan if the unit acts as contingency storage.
How does it compare with other Plasma Freezers variants?
Decide first whether you need freezing, storage or both. Blast models freeze plasma quickly and are usually followed by storage units. For storage, choose the temperature by the shelf life your regulator allows: storage at –25 °C or colder is commonly accepted for up to 36 months in European guidance, while –65 °C or colder extends shelf life under some standards. Then pick upright or chest format by floor space and access frequency, capacity in bags or liters, and monitoring needs. Check the recovery time after door opening, noise, ambient class and whether a CO2 or LN2 backup port is offered. Plan for electrical supply and heat load in the room.
Full specifications
| Temperature range | –25 °C to –40 °C |
|---|---|
| Net capacity | 80–200 L |
| Plasma unit capacity | approx. 40–120 units (250 mL) |
| Dimensions (W×D×H) | 600 × 650 × 830 mm |
| Uniformity | ≤ ±3 °C |
| Refrigerant | R290 or R404A (region dependent) |
| Alarms | High/low, door, power failure |
| Drawers | 2–4 |
| Ambient range | 10–32 °C |
| Power supply | 220 V, 50 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Small hospital blood banks
- Satellite transfusion points
- Contingency freezer for main storage
- Clinical research plasma
Key features
- Front-ventilated design fits below worktops
- Holds –30 °C to –40 °C in 80–200 L
- Drawers for labeled plasma units
- Independent alarm probe and power-failure alarm
- Lockable door to control access
- Optional data recorder and remote alarm contacts
Frequently asked questions about Undercounter Plasma Freezer
Yes, if kept at temperature, alarmed and validated. Many sites keep an empty, running unit for emergency transfer of stock from a failed main freezer. Test it regularly and document its alarm and mapping records.
About 40–60 standard 250 mL plasma units in cartons or drawers, since packaging and air spaces reduce usable volume. Always calculate by unit count and stacking rather than the liter rating.
Generally yes, because a smaller thermal mass and less insulation volume hold cold for a shorter time. Keep the door closed, cover with insulating blankets if needed and move stock to a validated freezer or dry ice within the time your plan defines.
Fresh frozen plasma is commonly stored at –25 °C or colder, with many sites using –30 °C to –40 °C. Some standards allow –18 °C to –25 °C for shorter periods, and –65 °C or colder for extended shelf life. Always follow your regulator and verify the product shelf life table.
Labile coagulation factors, notably Factor VIII, degrade more when plasma stays in the freezing range for long. Freezing the core to –30 °C within about one hour, often with blast air or contact plates, retains more activity, and guidelines define the time allowed from collection to freezing.
Plasma freezers carry independent alarm and recorder probes, tighter uniformity, battery-backed alarms and racking for blood bags, and are validated for transfusion-related storage. Laboratory freezers often lack these features and are not designed for storing components intended for patients.