Moisture Analyzers

煤中水分测定仪

MOI · Coal Testing Equipment · 5 models

By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM D3302, ASTM D3173, ASTM D2961

Standards referenced

  • ASTM D3302
  • ASTM D3173
  • ASTM D2961
  • ISO 5068-2
  • ISO 11722
  • ASTM D7582
  • GB/T 211
  • IEC 61010-1

What are Moisture Analyzers?

Moisture analyzers for coal determine the water content of coal, coke and solid biofuels by oven drying, halogen or microwave heating, or continuous on-belt measurement. Mines, preparation plants, power stations and trading laboratories use them for mass reconciliation, pricing and combustion control.

5 models of Moisture Analyzers

The 5 models below are current configurations; specifications are confirmed on quotation.

Forced-Air Drying Oven Moisture System for Total Moisture

强制通风干燥烘箱全水分测定系统

  • MOI-0001
  • Moisture Analyzers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Temperature range:
Ambient to 250 °C
Working temperature:
105–110 °C
Temperature stability:
± 1 °C
Chamber volume:
50–250 L
Balance resolution:
0.01 g
Sample mass:
10–500 g for total moisture

A forced-air drying oven moisture system dries coal samples at 105 to 110 °C with circulating air until constant mass, giving the reference total moisture value. It is required for contract analysis and for calibrating rapid meters.

Request a quote
View details

Halogen Drying Moisture Analyzer for Coal Analysis Samples

卤素干燥法煤分析试样水分测定仪

  • MOI-0002
  • Moisture Analyzers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Balance resolution:
0.001 g / 0.01 % moisture
Sample mass:
2–10 g
Drying temperature:
105 °C typical, up to 200 °C
Measurement time:
5–15 min
Repeatability:
± 0.2 % typical
Heating source:
Halogen lamp

A halogen drying moisture analyzer places a small coal sample on an internal balance and dries it with a halogen lamp, reporting moisture from continuous mass loss in minutes. It suits analysis sample moisture in busy laboratories.

Request a quote
View details

Microwave Rapid Moisture Analyzer for Coal

微波快速煤水分测定仪

  • MOI-0003
  • Moisture Analyzers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Moisture range:
0–40 %
Repeatability:
± 0.2–0.5 %
Measurement time:
5 s probe, 3–10 min drying
Sample mass:
20–500 g
Microwave power:
600–1000 W
Calibration:
Per coal type against oven results

A microwave rapid moisture analyzer dries or probes a coal sample with microwave energy and reports moisture in minutes, giving preparation plants and power stations fast feedback. Results are validated against the oven reference method.

Request a quote
View details

On-Line Microwave Moisture Analyzer for Coal Conveyors

输送带在线微波煤水分仪

  • MOI-0004
  • Moisture Analyzers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Moisture range:
0–40 %
Accuracy:
± 0.5 % absolute typical
Update interval:
1–2 s
Belt width:
800–2000 mm
Coal size:
0–50 mm typical
Measurement height:
200–500 mm above bed

An on-line microwave moisture analyzer mounts over a conveyor and measures the dielectric response of the coal bed continuously, without touching or drying the material. It supplies real-time moisture data for boiler and blending control.

Request a quote
View details

Neutron Moisture Gauge for Coal Conveyors

输送带中子煤水分仪

  • MOI-0005
  • Moisture Analyzers
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Moisture range:
2–30 %
Accuracy:
± 0.5 % absolute typical
Update interval:
About 60 s
Source:
Americium-241/beryllium, shielded
Belt width:
800–2000 mm
Coal size:
0–50 mm

A neutron moisture gauge measures the hydrogen content of the coal bed on a conveyor and converts it to moisture continuously. It complements ash or elemental on-line analyzers where real-time moisture is needed for control and reporting.

Request a quote
View details

Compare Moisture Analyzers models

ModelBalance resolutionSample massMeasurement timeRepeatabilityMoisture range
Forced-Air Drying Oven Moisture System for Total MoistureMOI-00010.01 g10–500 g for total moisture———
Halogen Drying Moisture Analyzer for Coal Analysis SamplesMOI-00020.001 g / 0.01 % moisture2–10 g5–15 min± 0.2 % typical—
Microwave Rapid Moisture Analyzer for CoalMOI-0003—20–500 g5 s probe, 3–10 min drying± 0.2–0.5 %0–40 %
On-Line Microwave Moisture Analyzer for Coal ConveyorsMOI-0004————0–40 %
Neutron Moisture Gauge for Coal ConveyorsMOI-0005————2–30 %

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Moisture Analyzers work?

Water in coal is reported in more than one form. Total moisture includes free surface water and the moisture held inside the coal particles; it is measured by the reference oven method, in which a sample is dried in air at 105 to 110 °C until constant mass and the mass loss is expressed on the as-received mass. The moisture in the general analysis sample is determined the same way on air-dried, pulverized coal, and for some low-rank coals drying in nitrogen is preferred to avoid oxidation. Halogen and infrared instruments place the sample on a built-in balance and dry it with a lamp, recording mass loss continuously, which shortens the test to minutes. Microwave instruments heat the water selectively and also use mass loss. On a conveyor, microwave or neutron gauges measure moisture continuously and non-destructively by relating the response of water molecules to the mass of coal present.

Which Moisture Analyzers variants are available?

  • Forced-Air Drying Oven Moisture System for Total Moisture — A forced-air drying oven moisture system dries coal samples at 105 to 110 °C with circulating air until constant mass, giving the reference total moisture value.
  • Halogen Drying Moisture Analyzer for Coal Analysis Samples — A halogen drying moisture analyzer places a small coal sample on an internal balance and dries it with a halogen lamp, reporting moisture from continuous mass loss in minutes.
  • Microwave Rapid Moisture Analyzer for Coal — A microwave rapid moisture analyzer dries or probes a coal sample with microwave energy and reports moisture in minutes, giving preparation plants and power stations fast feedback.
  • On-Line Microwave Moisture Analyzer for Coal Conveyors — An on-line microwave moisture analyzer mounts over a conveyor and measures the dielectric response of the coal bed continuously, without touching or drying the material.
  • Neutron Moisture Gauge for Coal Conveyors — A neutron moisture gauge measures the hydrogen content of the coal bed on a conveyor and converts it to moisture continuously.

How do I choose the right variant?

Selection depends on the form of moisture you must report and the speed you need. The forced-air oven remains the reference method for total moisture and is required for contract analysis and for calibrating faster instruments, so most laboratories keep one. Halogen drying balances are convenient for moisture in the general analysis sample because they are fast, need small samples and give a printed result, but they dry only a few grams and their agreement with the oven must be demonstrated. Microwave analyzers offer rapid batch results for preparation plant control. On-line microwave and neutron gauges provide continuous moisture data for boiler control, blending and stockpile management, and need a stable belt load and a size range within their specification. Check sample mass and particle size, temperature control, agreement with the reference method, dry-gas supply for nitrogen drying, and whether results are required on as-received, air-dried or dry basis.

Where are Moisture Analyzers used?

Moisture Analyzers are specified in total moisture for coal shipment pricing, power station combustion and mill control, preparation plant moisture reduction control, basis conversion for other coal indices and blending and stockpile moisture management.

Which standards and certifications apply?

Work with Moisture Analyzers is commonly governed by ASTM D3302, ASTM D3173, ASTM D2961, ISO 5068-2, ISO 11722, ASTM D7582, GB/T 211 and IEC 61010-1. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

For oven methods, verify the drying temperature across the working space, keep the oven clear of wet samples during a run and cool crucibles in a desiccator before weighing, since warm or damp samples drift upward in mass. Weigh immediately after cooling and keep records of drying time, because incomplete drying biases moisture low and shifts every subsequently reported basis. Nitrogen drying requires oxygen-free gas at a controlled flow and a leak-tight oven. For halogen or microwave instruments, verify agreement with the oven at least monthly using coal samples of similar rank, and re-check after lamp or sensor replacement. On-line gauges need calibration against oven results on stream samples taken across the full belt width, plus routine checks of the electronics and, for neutron units, a formal radiation program.

Frequently asked questions about Moisture Analyzers

Total moisture is measured on the coal as received, including free surface water, and is used for mass and price reconciliation. Analysis sample moisture is measured on air-dried pulverized coal and is needed to convert other results to a common basis.