Vertical Laminar Flow

垂直层流柜

VLF · Laminar Flow Cabinets · 5 models

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 14644-1 (cleanroom classification), ISO 14644-3 (test methods), IEST-RP-CC002 (unidirectional flow clean-air devices)

Standards referenced

  • ISO 14644-1 (cleanroom classification)
  • ISO 14644-3 (test methods)
  • IEST-RP-CC002 (unidirectional flow clean-air devices)
  • EN 1822 (HEPA and ULPA filters)
  • EU GMP Annex 1 (sterile manufacturing)
  • GB 50073 (cleanroom design code)

What are Vertical Laminar Flow?

Vertical laminar flow cabinets send HEPA-filtered air downward from the top of the enclosure across the work surface. They protect the work from particles and suit taller items, sterile handling and bench assembly where downward flow is preferred.

5 models of Vertical Laminar Flow

The 5 models below are current configurations; specifications are confirmed on quotation.

Vertical Laminar Flow Clean Bench

垂直层流洁净工作台

  • VLF-0001
  • Vertical Laminar Flow
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Flow direction:
Vertical, top to work surface
Filter class:
HEPA H14, ≥ 99.97 % at 0.3 µm
Downflow velocity:
0.3–0.5 m/s
Cleanliness:
ISO 5 at work surface
Width:
900–1800 mm
Height:
1000–1300 mm

A vertical laminar flow clean bench is an open workstation with HEPA air descending from the top over the work surface. It gives ISO 5 product protection and handles taller items better than horizontal flow.

Request a quote
View details

Ducted Vertical Laminar Flow Cabinet

管道式垂直层流柜

  • VLF-0002
  • Vertical Laminar Flow
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Flow direction:
Vertical, top to work surface
Filter class:
HEPA H14, ≥ 99.97 % at 0.3 µm
Downflow velocity:
0.3–0.5 m/s
Exhaust:
Ducted to atmosphere
Duct diameter:
200–300 mm
Airflow:
400–1200 m3/h

A ducted vertical laminar flow cabinet exhausts its downward air stream to atmosphere through a duct. It is chosen when exhaust must leave the room and downward product protection is preferred rather than recirculate.

Request a quote
View details

Recirculating Vertical Laminar Flow Cabinet

再循环式垂直层流柜

  • VLF-0003
  • Vertical Laminar Flow
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Flow direction:
Vertical, top to work surface
Filter class:
HEPA H14, ≥ 99.97 % at 0.3 µm
Downflow velocity:
0.3–0.5 m/s
Recirculation:
≈ 90 % with bleed
Exhaust:
None, room make-up and bleed
Width:
900–1800 mm

A recirculating vertical laminar flow cabinet returns filtered air to the work zone, avoiding a duct while maintaining downward product protection. It suits enclosed clean processes in controlled rooms and temperature-controlled areas.

Request a quote
View details

Stainless Steel Vertical Laminar Flow Cabinet

不锈钢垂直层流柜

  • VLF-0004
  • Vertical Laminar Flow
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Flow direction:
Vertical, top to work surface
Body material:
304 or 316L stainless steel
Filter class:
HEPA H14, ≥ 99.97 % at 0.3 µm
Downflow velocity:
0.3–0.5 m/s
Cleanliness:
ISO 5 at work surface
Finish:
Brushed or electro-polished

A stainless steel vertical laminar flow cabinet uses 304 or 316L construction for aseptic and GMP processes. Its cleanable surfaces and downward flow suit sterile handling and regulated inspection with documented materials.

Request a quote
View details

Mobile Vertical Laminar Flow Cabinet

移动式垂直层流柜

  • VLF-0005
  • Vertical Laminar Flow
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Flow direction:
Vertical, top to work surface
Filter class:
HEPA H14, ≥ 99.97 % at 0.3 µm
Downflow velocity:
0.3–0.5 m/s
Mobility:
Lockable castors, 4 positions
Width:
900–1500 mm
Exhaust:
Recirculating or flexible duct

A mobile vertical laminar flow cabinet brings downward HEPA protection to fixed equipment or temporary work positions. It is built on a wheeled frame for use at different locations within one facility.

Request a quote
View details

Compare Vertical Laminar Flow models

ModelFlow directionFilter classDownflow velocityCleanlinessWidth
Vertical Laminar Flow Clean BenchVLF-0001Vertical, top to work surfaceHEPA H14, ≥ 99.97 % at 0.3 µm0.3–0.5 m/sISO 5 at work surface900–1800 mm
Ducted Vertical Laminar Flow CabinetVLF-0002Vertical, top to work surfaceHEPA H14, ≥ 99.97 % at 0.3 µm0.3–0.5 m/s—900–1800 mm
Recirculating Vertical Laminar Flow CabinetVLF-0003Vertical, top to work surfaceHEPA H14, ≥ 99.97 % at 0.3 µm0.3–0.5 m/s—900–1800 mm
Stainless Steel Vertical Laminar Flow CabinetVLF-0004Vertical, top to work surfaceHEPA H14, ≥ 99.97 % at 0.3 µm0.3–0.5 m/sISO 5 at work surface900–1800 mm
Mobile Vertical Laminar Flow CabinetVLF-0005Vertical, top to work surfaceHEPA H14, ≥ 99.97 % at 0.3 µm0.3–0.5 m/s—900–1500 mm

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Vertical Laminar Flow work?

In a vertical laminar flow cabinet, room air is drawn through a prefilter and a HEPA filter located at the top, and a plenum and diffuser distribute it as a unidirectional stream that descends at 0.3–0.5 m/s over the work zone. Particles shed by the work are swept downward and away rather than towards the operator, and because the flow is vertical, taller items disturb it less than in a horizontal cabinet. Air leaves at the front of the work area and may be exhausted to the room or ducted, and some models recirculate most of the air. The supply filter removes at least 99.97 % of 0.3 µm particles for HEPA and 99.999 % for ULPA, giving ISO 5 or better at the work surface. Face velocity, filter integrity and particle counts are verified, and the cabinet must be sited away from draughts that could break the laminar stream.

Which Vertical Laminar Flow variants are available?

  • Vertical Laminar Flow Clean Bench — A vertical laminar flow clean bench is an open workstation with HEPA air descending from the top over the work surface.
  • Ducted Vertical Laminar Flow Cabinet — A ducted vertical laminar flow cabinet exhausts its downward air stream to atmosphere through a duct.
  • Recirculating Vertical Laminar Flow Cabinet — A recirculating vertical laminar flow cabinet returns filtered air to the work zone, avoiding a duct while maintaining downward product protection.
  • Stainless Steel Vertical Laminar Flow Cabinet — A stainless steel vertical laminar flow cabinet uses 304 or 316L construction for aseptic and GMP processes.
  • Mobile Vertical Laminar Flow Cabinet — A mobile vertical laminar flow cabinet brings downward HEPA protection to fixed equipment or temporary work positions.

How do I choose the right variant?

Choose vertical laminar flow when the work is tall, when the cabinet contains a central obstruction such as a jig, or when downward flow is preferred so that particles do not travel towards the operator. Decide whether the cabinet recirculates, exhausts to the room or is ducted, and select HEPA H14 for ISO 5 or ULPA for ISO 4 or better. Match internal height and working depth to the equipment, and consider a sash or partial front for increased operator comfort. For regulated or aseptic work, choose stainless steel with cleanable surfaces and documentation. Confirm face velocity and cleanliness at commissioning. Vertical designs are often preferred in cell culture and sterile handling where a downward draught over open vessels reduces contamination from above.

Where are Vertical Laminar Flow used?

Vertical Laminar Flow are specified in cell culture and sterile handling, electronics and semiconductor assembly, media preparation and plating, inspection of tall or jigged parts and aseptic filling and packaging.

Which standards and certifications apply?

Work with Vertical Laminar Flow is commonly governed by ISO 14644-1 (cleanroom classification), ISO 14644-3 (test methods), IEST-RP-CC002 (unidirectional flow clean-air devices), EN 1822 (HEPA and ULPA filters), EU GMP Annex 1 (sterile manufacturing) and GB 50073 (cleanroom design code). Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Site the cabinet away from doors, air diffusers and people traffic, since draughts above about 0.2 m/s disturb the downward stream. Verify filter integrity and face velocity at installation and at least annually, and change prefilters every 3–6 months. Place tall items so they do not block the diffuser, and keep the front opening clear so air can exit. Clean surfaces with compatible agents and avoid generating aerosols that load the filter. The cabinet protects the work rather than the operator, so do not use it for hazardous aerosols or chemical vapour. Record requalification results, and confirm the recirculated or ducted exhaust path meets room requirements.

Frequently asked questions about Vertical Laminar Flow

Vertical flow sweeps particles downward and away from the operator and handles tall items better, since a central obstruction disturbs a horizontal stream more. It is often preferred for cell culture and sterile handling.

Need help specifying Vertical Laminar Flow?

Request a quote