Clean Benches

洁净工作台(层流柜)

CBE · Laminar Flow Cabinets · 5 models

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 14644-1 (cleanroom classification), ISO 14644-3 (test methods), IEST-RP-CC002 (unidirectional flow clean-air devices)

Standards referenced

  • ISO 14644-1 (cleanroom classification)
  • ISO 14644-3 (test methods)
  • IEST-RP-CC002 (unidirectional flow clean-air devices)
  • EN 1822 (HEPA and ULPA filters)
  • EU GMP Annex 1 (sterile manufacturing)
  • GB 50073 (cleanroom design code)

What are Clean Benches?

Clean benches are laminar flow workstations that protect products and samples with HEPA or ULPA filtered air, without protecting the operator. Horizontal, vertical, ducted, recirculating and stainless steel forms cover inspection, assembly and sterile work.

5 models of Clean Benches

The 5 models below are current configurations; specifications are confirmed on quotation.

Horizontal Flow Clean Bench

水平流洁净工作台

  • CBE-0001
  • Clean Benches
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Flow direction:
Horizontal, rear to front
Filter class:
HEPA H14, ≥ 99.97 % at 0.3 µm
Face velocity:
0.3–0.5 m/s
Cleanliness:
ISO 5 at work surface
Width:
900–1800 mm
Work surface:
Stainless steel 304

A horizontal flow clean bench supplies HEPA air from a rear grille across the work surface, giving an open, unobstructed clean zone. It suits flat inspection and assembly tasks with clear access.

Request a quote
View details

Vertical Flow Clean Bench

垂直流洁净工作台

  • CBE-0002
  • Clean Benches
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Flow direction:
Vertical, top to work surface
Filter class:
HEPA H14, ≥ 99.97 % at 0.3 µm
Downflow velocity:
0.3–0.5 m/s
Cleanliness:
ISO 5 at work surface
Width:
900–1800 mm
Height:
1000–1300 mm

A vertical flow clean bench delivers HEPA air downward from the top over the work surface. It suits taller items and tasks where downward flow keeps particles away from open vessels and jigs.

Request a quote
View details

Ducted Clean Bench

管道式洁净工作台

  • CBE-0003
  • Clean Benches
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Flow direction:
Horizontal or vertical
Filter class:
HEPA H14, ≥ 99.97 % at 0.3 µm
Face velocity:
0.3–0.5 m/s
Exhaust:
Ducted to atmosphere
Duct diameter:
200–300 mm
Airflow:
400–1200 m3/h

A ducted clean bench exhausts its air to atmosphere instead of returning it to the room. It is chosen where exhaust must leave the room or where recirculation is not permitted by local rules.

Request a quote
View details

Recirculating Clean Bench

再循环式洁净工作台

  • CBE-0004
  • Clean Benches
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Flow direction:
Horizontal or vertical
Filter class:
HEPA H14, ≥ 99.97 % at 0.3 µm
Face velocity:
0.3–0.5 m/s
Recirculation:
≈ 90 % with bleed
Exhaust:
None, room make-up and bleed
Width:
900–1800 mm

A recirculating clean bench returns filtered air to the work zone instead of exhausting it, so no duct is needed. It suits clean, non-hazardous work in temperature-controlled rooms and low-humidity laboratory spaces.

Request a quote
View details

Stainless Steel GMP Clean Bench

不锈钢 GMP 洁净工作台

  • CBE-0005
  • Clean Benches
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Flow direction:
Horizontal or vertical
Body material:
304 or 316L stainless steel
Filter class:
HEPA H14, ≥ 99.97 % at 0.3 µm
Face velocity:
0.3–0.5 m/s
Cleanliness:
ISO 5 at work surface
Finish:
Brushed or electro-polished

A stainless steel GMP clean bench uses 304 or 316L construction with cleanable surfaces for regulated aseptic work. It provides product protection with documentation to support qualification and audit readiness in regulated facilities.

Request a quote
View details

Compare Clean Benches models

ModelFlow directionFilter classFace velocityCleanlinessWidth
Horizontal Flow Clean BenchCBE-0001Horizontal, rear to frontHEPA H14, ≥ 99.97 % at 0.3 µm0.3–0.5 m/sISO 5 at work surface900–1800 mm
Vertical Flow Clean BenchCBE-0002Vertical, top to work surfaceHEPA H14, ≥ 99.97 % at 0.3 µm—ISO 5 at work surface900–1800 mm
Ducted Clean BenchCBE-0003Horizontal or verticalHEPA H14, ≥ 99.97 % at 0.3 µm0.3–0.5 m/s—900–1800 mm
Recirculating Clean BenchCBE-0004Horizontal or verticalHEPA H14, ≥ 99.97 % at 0.3 µm0.3–0.5 m/s—900–1800 mm
Stainless Steel GMP Clean BenchCBE-0005Horizontal or verticalHEPA H14, ≥ 99.97 % at 0.3 µm0.3–0.5 m/sISO 5 at work surface900–1800 mm

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Clean Benches work?

A clean bench supplies filtered air in one direction across an open work surface, so particles generated by the work or carried in the room are swept away from the sample. Room air passes a prefilter and then a HEPA filter rated at least 99.97 % efficient at 0.3 µm, or a ULPA filter at 99.999 %, and a diffuser makes the stream uniform at 0.3–0.5 m/s. Horizontal designs flow from the back of the bench to the front, while vertical designs descend from the top. The open front gives good access but no operator protection, so clean benches are used only for work that produces no hazardous aerosol or chemical vapour. The work zone can reach ISO 5 in a suitable room. Filter loading is shown by pressure, and airflow and filter integrity must be verified, because draughts and obstructions disturb the laminar stream.

Which Clean Benches variants are available?

  • Horizontal Flow Clean Bench — A horizontal flow clean bench supplies HEPA air from a rear grille across the work surface, giving an open, unobstructed clean zone.
  • Vertical Flow Clean Bench — A vertical flow clean bench delivers HEPA air downward from the top over the work surface.
  • Ducted Clean Bench — A ducted clean bench exhausts its air to atmosphere instead of returning it to the room.
  • Recirculating Clean Bench — A recirculating clean bench returns filtered air to the work zone instead of exhausting it, so no duct is needed.
  • Stainless Steel GMP Clean Bench — A stainless steel GMP clean bench uses 304 or 316L construction with cleanable surfaces for regulated aseptic work.

How do I choose the right variant?

Choose the flow direction first: horizontal for flat work needing clear access, vertical for tall items and where downward flow is preferred. Then decide the exhaust arrangement: ducted where exhaust must leave the room, recirculating where no duct is available and the work is clean. Select the construction: powder-coated steel for general use, and stainless steel for aseptic, GMP or high-humidity environments with cleanable surfaces and documentation. Choose filter class for the cleanliness target, HEPA H14 for ISO 5 and ULPA for ISO 4 or better, and match width and working height to the equipment. Confirm the bench does not need to protect the operator, and if it does, specify a biosafety cabinet or fume hood instead. Verify face velocity, filter integrity and particle counts at commissioning, and plan requalification.

Where are Clean Benches used?

Clean Benches are specified in aseptic assembly and inspection, media preparation and plating, electronics and optics work, device packaging and filling and particle-sensitive metrology.

Which standards and certifications apply?

Work with Clean Benches is commonly governed by ISO 14644-1 (cleanroom classification), ISO 14644-3 (test methods), IEST-RP-CC002 (unidirectional flow clean-air devices), EN 1822 (HEPA and ULPA filters), EU GMP Annex 1 (sterile manufacturing) and GB 50073 (cleanroom design code). Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Site the bench away from doors, air diffusers and traffic, because draughts above about 0.2 m/s break the laminar stream. Verify filter integrity and face velocity at installation and at least annually, changing prefilters every 3–6 months. Keep the work surface free of large items, place objects to the side rather than in front of the filter face, and do not block the air exit. Clean with compatible agents, and avoid aerosols that would load the filter. Never use a clean bench for hazardous aerosols or volatile chemicals, since the open front offers no protection. Record requalification and filter changes, and confirm that the recirculated or ducted exhaust suits the room and any local rules.

Frequently asked questions about Clean Benches

It protects the work and samples from particles and microbes by supplying HEPA or ULPA filtered air across the surface. It does not protect the operator, so hazardous aerosols and chemical vapour are not contained.

Need help specifying Clean Benches?

Request a quote