Horizontal Laminar Flow

水平层流柜

HLF · Laminar Flow Cabinets · 5 models

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 14644-1 (cleanroom classification), ISO 14644-3 (test methods), IEST-RP-CC002 (unidirectional flow clean-air devices)

Standards referenced

  • ISO 14644-1 (cleanroom classification)
  • ISO 14644-3 (test methods)
  • IEST-RP-CC002 (unidirectional flow clean-air devices)
  • EN 1822 (HEPA and ULPA filters)
  • EU GMP Annex 1 (sterile manufacturing)
  • GB 50073 (cleanroom design code)

What are Horizontal Laminar Flow?

Horizontal laminar flow cabinets pass HEPA-filtered air from the rear across the work surface towards the operator, giving an unobstructed clean zone. They are used for assembly, inspection, media preparation and other product-protection tasks.

5 models of Horizontal Laminar Flow

The 5 models below are current configurations; specifications are confirmed on quotation.

Horizontal Laminar Flow Clean Bench

水平层流洁净工作台

  • HLF-0001
  • Horizontal Laminar Flow
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Flow direction:
Horizontal, rear to front
Filter class:
HEPA H14, ≥ 99.97 % at 0.3 µm
Face velocity:
0.3–0.5 m/s
Cleanliness:
ISO 5 at work surface
Width:
900–1800 mm
Work surface:
Stainless steel 304

A horizontal laminar flow clean bench is an open-front workbench with HEPA air crossing from the rear grille. It provides ISO 5 protection for the work with clear access for assembly and inspection tasks.

Request a quote
View details

Ducted Horizontal Laminar Flow Cabinet

管道式水平层流柜

  • HLF-0002
  • Horizontal Laminar Flow
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Flow direction:
Horizontal, rear to front
Filter class:
HEPA H14, ≥ 99.97 % at 0.3 µm
Face velocity:
0.3–0.5 m/s
Exhaust:
Ducted to atmosphere
Duct diameter:
200–300 mm
Airflow:
400–1200 m3/h

A ducted horizontal laminar flow cabinet exhausts its air to atmosphere through a duct after crossing the work surface. It is chosen when exhaust air must leave the room for cleanliness or odour control.

Request a quote
View details

Recirculating Horizontal Laminar Flow Cabinet

再循环式水平层流柜

  • HLF-0003
  • Horizontal Laminar Flow
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Flow direction:
Horizontal, rear to front
Filter class:
HEPA H14, ≥ 99.97 % at 0.3 µm
Face velocity:
0.3–0.5 m/s
Recirculation:
≈ 90 % with bleed
Exhaust:
None, room make-up and bleed
Width:
900–1800 mm

A recirculating horizontal laminar flow cabinet returns filtered air to the work zone instead of exhausting it, preserving room conditions. It suits enclosed clean processes where ducting is impractical and energy saving is valuable.

Request a quote
View details

Stainless Steel Horizontal Laminar Flow Cabinet

不锈钢水平层流柜

  • HLF-0004
  • Horizontal Laminar Flow
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Flow direction:
Horizontal, rear to front
Body material:
304 or 316L stainless steel
Filter class:
HEPA H14, ≥ 99.97 % at 0.3 µm
Face velocity:
0.3–0.5 m/s
Cleanliness:
ISO 5 at work surface
Finish:
Brushed or electro-polished

A stainless steel horizontal laminar flow cabinet uses 304 or 316L construction for aseptic and GMP environments. Its smooth, cleanable surfaces suit pharmaceutical and medical-device work and can be disinfected and documented.

Request a quote
View details

Mobile Horizontal Laminar Flow Cabinet

移动式水平层流柜

  • HLF-0005
  • Horizontal Laminar Flow
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Flow direction:
Horizontal, rear to front
Filter class:
HEPA H14, ≥ 99.97 % at 0.3 µm
Face velocity:
0.3–0.5 m/s
Mobility:
Lockable castors, 4 positions
Width:
900–1500 mm
Exhaust:
Recirculating or flexible duct

A mobile horizontal laminar flow cabinet is mounted on castors for use at different locations within a facility. It brings ISO 5 protection to fixed equipment, temporary work stations or metrology positions.

Request a quote
View details

Compare Horizontal Laminar Flow models

ModelFlow directionFilter classFace velocityCleanlinessWidth
Horizontal Laminar Flow Clean BenchHLF-0001Horizontal, rear to frontHEPA H14, ≥ 99.97 % at 0.3 µm0.3–0.5 m/sISO 5 at work surface900–1800 mm
Ducted Horizontal Laminar Flow CabinetHLF-0002Horizontal, rear to frontHEPA H14, ≥ 99.97 % at 0.3 µm0.3–0.5 m/s—900–1800 mm
Recirculating Horizontal Laminar Flow CabinetHLF-0003Horizontal, rear to frontHEPA H14, ≥ 99.97 % at 0.3 µm0.3–0.5 m/s—900–1800 mm
Stainless Steel Horizontal Laminar Flow CabinetHLF-0004Horizontal, rear to frontHEPA H14, ≥ 99.97 % at 0.3 µm0.3–0.5 m/sISO 5 at work surface900–1800 mm
Mobile Horizontal Laminar Flow CabinetHLF-0005Horizontal, rear to frontHEPA H14, ≥ 99.97 % at 0.3 µm0.3–0.5 m/s—900–1500 mm

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Horizontal Laminar Flow work?

In a horizontal laminar flow cabinet, room air is drawn through a prefilter and a HEPA filter and then pushed through a rear plenum and diffuser. It leaves the back grille as a unidirectional stream at 0.3–0.5 m/s and crosses the entire work surface before reaching the operator, carrying particles and microbes away from the work. Because the stream comes from behind the work, the operator has clear access to the whole bench with no barrier or downward draught. Air may then exhaust to the room or be ducted or recirculated depending on the model. The filter removes at least 99.97 % of 0.3 µm particles for HEPA and 99.999 % for ULPA. Face velocity, filter integrity and particle counts are the performance measures, and the laminar stream is easily disturbed by draughts, so the cabinet must be sited away from doors and air supply diffusers.

Which Horizontal Laminar Flow variants are available?

  • Horizontal Laminar Flow Clean Bench — A horizontal laminar flow clean bench is an open-front workbench with HEPA air crossing from the rear grille.
  • Ducted Horizontal Laminar Flow Cabinet — A ducted horizontal laminar flow cabinet exhausts its air to atmosphere through a duct after crossing the work surface.
  • Recirculating Horizontal Laminar Flow Cabinet — A recirculating horizontal laminar flow cabinet returns filtered air to the work zone instead of exhausting it, preserving room conditions.
  • Stainless Steel Horizontal Laminar Flow Cabinet — A stainless steel horizontal laminar flow cabinet uses 304 or 316L construction for aseptic and GMP environments.
  • Mobile Horizontal Laminar Flow Cabinet — A mobile horizontal laminar flow cabinet is mounted on castors for use at different locations within a facility.

How do I choose the right variant?

Choose a horizontal laminar flow cabinet when the task needs clear, unobstructed access to the work surface and the operator does not need protection from aerosols. Decide whether the cabinet recirculates, exhausts to the room or is ducted, based on room conditions and the process. Select filter class by the required cleanliness, commonly HEPA H14 for ISO 5 and ULPA for ISO 4 or better, and match width and working height to the equipment. For GMP or aseptic use, choose stainless steel construction with cleanable surfaces. Confirm face velocity, filter integrity and particle counts at commissioning, and check that the site has no strong draughts. Horizontal flow is less suitable for tall work or when the operator must lean over the work, since the air then travels towards the operator's breathing zone.

Where are Horizontal Laminar Flow used?

Horizontal Laminar Flow are specified in electronics and optics assembly, media preparation and plating, inspection and packaging, instrument and component loading and metrology and particle-sensitive work.

Which standards and certifications apply?

Work with Horizontal Laminar Flow is commonly governed by ISO 14644-1 (cleanroom classification), ISO 14644-3 (test methods), IEST-RP-CC002 (unidirectional flow clean-air devices), EN 1822 (HEPA and ULPA filters), EU GMP Annex 1 (sterile manufacturing) and GB 50073 (cleanroom design code). Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Site the cabinet away from doors, windows, air diffusers and walkways, since draughts above 0.2 m/s disturb the horizontal stream. Verify filter integrity and face velocity at installation and at least annually, changing prefilters every 3–6 months. Keep the work area clear of large objects that block the stream, and place items at the sides rather than directly in front of the filter face. Clean the work surface and interior with compatible agents and avoid aerosols that could contaminate the filter. Do not use the cabinet for hazardous aerosols or chemical vapour, since it protects only the work. Record requalification results to support audits.

Frequently asked questions about Horizontal Laminar Flow

Horizontal flow crosses the bench from the back and gives the operator clear access to the whole work surface without a downward draught. It suits flat assembly and inspection work best.

Need help specifying Horizontal Laminar Flow?