Ductless Fume Hoods

无管道通风柜

DUC · Fume Hoods · 5 models

By Lab Manufacturers China Technical TeamLast reviewed Standards: ASHRAE 110 (testing performance of laboratory fume hoods), AFNOR NF X 15-211 (ductless fume cupboards), ISO 14644-1

Standards referenced

  • ASHRAE 110 (testing performance of laboratory fume hoods)
  • AFNOR NF X 15-211 (ductless fume cupboards)
  • ISO 14644-1
  • EN 14175-1 (fume cupboards, vocabulary)
  • GB/T 34269
  • IEC 61010-1

What are Ductless Fume Hoods?

Ductless fume hoods draw air through a sash opening and filter it through activated carbon or HEPA media before returning it to the room. They are used for low-volume work with known chemicals, in locations where ducting is impractical.

5 models of Ductless Fume Hoods

The 5 models below are current configurations; specifications are confirmed on quotation.

Activated Carbon Ductless Fume Hood

活性炭无管道通风柜

  • DUC-0001
  • Ductless Fume Hoods
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Filter media:
Granular activated carbon
Carbon mass:
5–20 kg
Bed depth:
25–50 mm
Airflow:
300–800 m3/h
Face velocity:
0.4–0.5 m/s
Width:
600–1500 mm

An activated carbon ductless hood filters organic vapours through carbon adsorption beds before recirculating air into the room. It suits low-volume solvent handling in teaching and small laboratories where ducting is impractical.

Request a quote
View details

HEPA and Carbon Ductless Fume Hood

HEPA 与活性炭无管道通风柜

  • DUC-0002
  • Ductless Fume Hoods
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Filter stages:
Prefilter, carbon, HEPA
HEPA grade:
H13 or H14
Airflow:
300–700 m3/h
Face velocity:
0.4–0.5 m/s
Carbon mass:
5–15 kg
Width:
600–1200 mm

A combined HEPA and carbon ductless hood filters both particulates and organic vapours in a two-stage design. It suits work with powders and solvents, such as weighing and dissolving, in small laboratories.

Request a quote
View details

Acid Gas Ductless Fume Hood

酸性气体无管道通风柜

  • DUC-0003
  • Ductless Fume Hoods
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Filter media:
Impregnated carbon or alumina media
Media mass:
5–15 kg
Airflow:
300–600 m3/h
Face velocity:
0.4–0.5 m/s
Body material:
Polypropylene
Width:
600–1200 mm

An acid gas ductless hood uses chemically impregnated carbon or alkaline media to neutralize acid vapours such as HCl, HF and SO2. It is used for small-scale acid handling where ducting is unavailable.

Request a quote
View details

Portable Ductless Fume Extractor Hood

便携式无管道排烟通风罩

  • DUC-0004
  • Ductless Fume Hoods
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Airflow:
100–400 m3/h
Capture velocity:
≈ 0.5 m/s at 100–200 mm
Filter layers:
Prefilter, HEPA, carbon
Weight:
10–30 kg
Noise level:
50–60 dB(A)
Power supply:
220 V, 50 Hz, 100–250 W

A portable ductless fume extractor hood is a small, movable unit with a capture hood and filter set for soldering, adhesives or light chemical tasks. It provides local extraction at the source rather than an enclosed workspace.

Request a quote
View details

Ammonia and Amine Ductless Fume Hood

氨与胺类无管道通风柜

  • DUC-0005
  • Ductless Fume Hoods
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Filter media:
Acid-impregnated activated carbon
Media mass:
5–15 kg
Bed depth:
25–50 mm
Airflow:
300–700 m3/h
Face velocity:
0.4–0.5 m/s
Gases handled:
NH3 and volatile amines (per media)

An ammonia and amine ductless hood uses acid-impregnated carbon media to chemisorb alkaline vapours such as ammonia, trimethylamine and volatile amines. It is selected for small-scale work with ammonia solutions, buffers and amine chemistry where ducting is not available at the bench.

Request a quote
View details

Compare Ductless Fume Hoods models

ModelFilter mediaCarbon massBed depthAirflowFace velocity
Activated Carbon Ductless Fume HoodDUC-0001Granular activated carbon5–20 kg25–50 mm300–800 m3/h0.4–0.5 m/s
HEPA and Carbon Ductless Fume HoodDUC-0002—5–15 kg—300–700 m3/h0.4–0.5 m/s
Acid Gas Ductless Fume HoodDUC-0003Impregnated carbon or alumina media——300–600 m3/h0.4–0.5 m/s
Portable Ductless Fume Extractor HoodDUC-0004———100–400 m3/h—
Ammonia and Amine Ductless Fume HoodDUC-0005Acid-impregnated activated carbon—25–50 mm300–700 m3/h0.4–0.5 m/s

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Ductless Fume Hoods work?

A ductless fume hood uses a fan to pull room air through the sash opening at 0.4–0.5 m/s across the work area, then through one or more filter stages before discharge back into the room. A prefilter removes dust, and activated carbon beds adsorb organic vapours through physical adsorption. Chemically impregnated carbon or specialist media can capture acids, ammonia or formaldehyde. A HEPA stage can be added for particles. Sensors or timers indicate filter saturation, and airflow monitors ensure correct face velocity. Because filters have finite capacity, the hood is limited to known chemicals in limited quantities, and filter selection must match the vapour. The body is typically polypropylene or epoxy-coated steel, with lighting and a control panel.

Which Ductless Fume Hoods variants are available?

  • Activated Carbon Ductless Fume Hood — An activated carbon ductless hood filters organic vapours through carbon adsorption beds before recirculating air into the room.
  • HEPA and Carbon Ductless Fume Hood — A combined HEPA and carbon ductless hood filters both particulates and organic vapours in a two-stage design.
  • Acid Gas Ductless Fume Hood — An acid gas ductless hood uses chemically impregnated carbon or alkaline media to neutralize acid vapours such as HCl, HF and SO2.
  • Portable Ductless Fume Extractor Hood — A portable ductless fume extractor hood is a small, movable unit with a capture hood and filter set for soldering, adhesives or light chemical tasks.
  • Ammonia and Amine Ductless Fume Hood — An ammonia and amine ductless hood uses acid-impregnated carbon media to chemisorb alkaline vapours such as ammonia, trimethylamine and volatile amines.

How do I choose the right variant?

Select by the chemicals used. Every application needs a chemical compatibility assessment from the supplier to match filter media, and the assessment should include quantities, frequency and breakthrough behaviour. Choose an activated carbon filter for organic solvents, impregnated carbon for acids or amines, and HEPA for particulates. Consider filter monitoring, such as gas sensors that signal breakthrough, rather than timers alone. Choose width, typically 600–1500 mm, noise level, and whether a base cabinet for storage is required. Ductless hoods are not suitable for unknown, high-volume or highly toxic chemicals, or for heated perchloric acid. Confirm local regulations on recirculating air, since some jurisdictions restrict their use.

Where are Ductless Fume Hoods used?

Ductless Fume Hoods are specified in teaching laboratories, quality control, pharmacies, electronics repair and small-scale chemistry.

Which standards and certifications apply?

Work with Ductless Fume Hoods is commonly governed by ASHRAE 110 (testing performance of laboratory fume hoods), AFNOR NF X 15-211 (ductless fume cupboards), ISO 14644-1, EN 14175-1 (fume cupboards, vocabulary), GB/T 34269 and IEC 61010-1. Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Establish a chemical register before purchase and have the supplier confirm filter compatibility in writing. Change filters at the recommended interval or sooner if gas sensors or odour indicate breakthrough, because carbon saturation is sudden at the end of life. Test airflow and filter seals on installation and at least every 6–12 months, keeping records for audit. Place the hood away from doors and air currents, and with clearance to allow filter replacement. Dispose of used filters as hazardous waste. Train users to restrict quantities, keep sashes low and never use the hood for chemicals outside the compatibility list.

Frequently asked questions about Ductless Fume Hoods

A ductless fume hood filters air through activated carbon or HEPA media and returns it to the room, so it needs no duct. It is used for low-volume work with known chemicals where ducting is impractical.

Need help specifying Ductless Fume Hoods?