What are Class III Cabinets?

Class III biosafety cabinets are gas-tight, negative-pressure gloveboxes with HEPA-filtered supply and exhaust and no direct operator access. They give the highest containment for Risk Group 4 pathogen agents and work requiring complete isolation.

5 models of Class III Cabinets

The 5 models below are current configurations; specifications are confirmed on quotation.

Class III Glovebox Biosafety Cabinet

III 级手套箱生物安全柜

  • CLN-0001
  • Class III Cabinets
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Cabinet class:
Class III
Negative pressure:
100–200 Pa below room
Exhaust filtration:
Double HEPA H14
Supply filtration:
HEPA H14
Glove ports:
2–4, long gauntlet
Enclosure material:
Welded 304 or 316L stainless

A Class III glovebox biosafety cabinet is a gas-tight, negative-pressure enclosure operated through integral gloves. It provides the highest containment for Risk Group 4 work with double HEPA-filtered exhaust and sealed transfer ports.

Request a quote
View details

Class III Glovebox with Dunk Tank Pass-Through

带浸没槽传递的 III 级手套箱

  • CLN-0002
  • Class III Cabinets
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Cabinet class:
Class III
Pass-through type:
Dunk tank and double-door hatch
Tank diameter:
200–400 mm
Negative pressure:
100–200 Pa below room
Exhaust filtration:
Double HEPA H14
Glove ports:
2–4, long gauntlet

A Class III glovebox with a dunk tank passes small items through a disinfectant bath so the seal is never opened to the room. It is used where frequent small transfers of tools and samples occur.

Request a quote
View details

Class III Negative-Pressure Animal Isolator

III 级负压动物隔离器

  • CLN-0003
  • Class III Cabinets
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Cabinet class:
Class III isolator
Negative pressure:
100–250 Pa below room
Supply filtration:
HEPA H14
Exhaust filtration:
Double HEPA H14
Air changes:
15–50 ACH
Temperature control:
20–26 °C ± 2 °C

A Class III negative-pressure animal isolator houses infected or immunocompromised animals in a sealed, ventilated enclosure. It protects operators and the facility from aerosols while keeping the animals isolated. These units are used in high-containment animal facilities.

Request a quote
View details

Class III Anaerobic Glovebox Cabinet

III 级厌氧手套箱安全柜

  • CLN-0004
  • Class III Cabinets
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Cabinet class:
Class III anaerobic
Oxygen level:
≤ 5 ppm, down to 1 ppm
Atmosphere:
N2 or N2/H2/CO2 mix
Negative pressure:
100–200 Pa below room
Exhaust filtration:
Double HEPA H14
Catalyst:
Palladium, heated

A Class III anaerobic glovebox cabinet maintains a sealed oxygen-free atmosphere while providing containment for anaerobic pathogens. It combines anaerobic culture with high-level operator protection. It suits strict anaerobe culture where aerosols must be contained.

Request a quote
View details

Class III Lead-Lined Glovebox Cabinet

III 级铅屏蔽手套箱安全柜

  • CLN-0005
  • Class III Cabinets
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
Cabinet class:
Class III, lead-lined
Shielding thickness:
2–50 mm lead equivalent
Negative pressure:
100–200 Pa below room
Exhaust filtration:
Double HEPA H14
Viewing panel:
Lead glass or lead-acrylic
Glove ports:
2–4 with shielded cuffs

A Class III lead-lined glovebox cabinet adds radiation shielding to the gas-tight enclosure for handling radioactive materials. It provides containment and shielding in one sealed workspace. These cabinets are used in radiochemistry and nuclear medicine research.

Request a quote
View details

Compare Class III Cabinets models

ModelCabinet classNegative pressureExhaust filtrationSupply filtrationGlove ports
Class III Glovebox Biosafety CabinetCLN-0001Class III100–200 Pa below roomDouble HEPA H14HEPA H142–4, long gauntlet
Class III Glovebox with Dunk Tank Pass-ThroughCLN-0002Class III100–200 Pa below roomDouble HEPA H14—2–4, long gauntlet
Class III Negative-Pressure Animal IsolatorCLN-0003Class III isolator100–250 Pa below roomDouble HEPA H14HEPA H142–6
Class III Anaerobic Glovebox CabinetCLN-0004Class III anaerobic100–200 Pa below roomDouble HEPA H14—2–4, long gauntlet
Class III Lead-Lined Glovebox CabinetCLN-0005Class III, lead-lined100–200 Pa below roomDouble HEPA H14—2–4 with shielded cuffs

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

How do Class III Cabinets work?

A Class III cabinet is a sealed enclosure operated through long gauntlet gloves bonded to the front panel, so the operator never breaks the barrier. The interior is held at negative pressure of at least 100–200 Pa relative to the room, and all supply and exhaust air passes two HEPA filters, with the exhaust filter usually preceded by an incinerator or other treatment for the most hazardous agents. Because the enclosure is gas-tight, it is tested for leak tightness as well as airflow. Materials enter and leave through double-door pass-throughs, a dunk tank or a steriliser so the seal is never opened directly. A double HEPA exhaust protects against filter failure, and the exhausted air is monitored. Internal lighting, glove ports and a transfer hatch are standard. The design removes operator exposure risk but requires careful procedures for glove changes, pass-through cycles and decontamination.

Which Class III Cabinets variants are available?

  • Class III Glovebox Biosafety Cabinet — A Class III glovebox biosafety cabinet is a gas-tight, negative-pressure enclosure operated through integral gloves.
  • Class III Glovebox with Dunk Tank Pass-Through — A Class III glovebox with a dunk tank passes small items through a disinfectant bath so the seal is never opened to the room.
  • Class III Negative-Pressure Animal Isolator — A Class III negative-pressure animal isolator houses infected or immunocompromised animals in a sealed, ventilated enclosure.
  • Class III Anaerobic Glovebox Cabinet — A Class III anaerobic glovebox cabinet maintains a sealed oxygen-free atmosphere while providing containment for anaerobic pathogens.
  • Class III Lead-Lined Glovebox Cabinet — A Class III lead-lined glovebox cabinet adds radiation shielding to the gas-tight enclosure for handling radioactive materials.

How do I choose the right variant?

Class III cabinets are chosen when a risk assessment identifies Risk Group 4 agents or operations that must be completely isolated from the operator and the environment. Select the glove system and number of glove ports for the manual tasks, and the pass-through arrangement, such as a double-door hatch, dunk tank or connected autoclave. Confirm the negative pressure setpoint, the double HEPA exhaust and any required exhaust treatment such as incineration. Check that the room has the exhaust and make-up air capacity, and that the cabinet can be leak tested to ISO 10648-2 or the applicable standard. Decide whether atmosphere control is needed for anaerobic work, and whether lead shielding is required for radionuclide use. Plan decontamination and glove replacement procedures before installation.

Where are Class III Cabinets used?

Class III Cabinets are specified in risk Group 4 pathogen work, highly pathogenic virus culture, aerosol challenge and animal studies, radionuclide and toxic chemical handling and high-containment diagnostics.

Which standards and certifications apply?

Work with Class III Cabinets is commonly governed by EN 12469 (biosafety cabinets), NSF/ANSI 49 (biosafety cabinetry), ISO 10648-2 (glovebox leak tightness), ISO 14644-1 (cleanroom classification), EU GMP Annex 1 (sterile manufacturing) and GB 19489 (biosafety laboratory requirements). Instrument certifications such as CE marking are confirmed per configuration and never assumed.

What are the key considerations before purchase?

Verify leak tightness and airflow at installation and at least annually, since a gas-tight cabinet depends on intact gaskets, glove seals and weld integrity. Follow a defined glove inspection and replacement schedule, checking for pinholes before each session and replacing at the first sign of wear. Do not open the enclosure to the room; use pass-throughs and decontamination cycles for all material movement. Confirm the exhaust fan is dedicated and interlocked, with alarms for loss of negative pressure. Provide a written decontamination procedure using a validated agent, and record every cycle. Confirm the room pressure relationship and make-up air so that the cabinet does not disturb the surrounding laboratory. Train operators on emergency procedures, including power or exhaust failure.

Frequently asked questions about Class III Cabinets

It is gas-tight and operated through gloves, so the operator is never exposed. Interior pressure is negative, both supply and exhaust are double HEPA filtered, and materials pass through sealed transfer ports rather than an open sash.

Need help specifying Class III Cabinets?

Request a quote