Quantitative Phase Analysis X-Ray Diffractometer

定量物相分析 X 射线衍射仪

  • SKU XRD-0006
  • XRD
  • CE (to be confirmed)
  • Radiation safety enclosure (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
2-theta range5–120°
Angular accuracy±0.01°
X-ray tube power1–3 kW
Detectorsolid-state with wide linear range
Quantification methodsRietveld, internal standard, RIR
Amorphous determinationinternal standard method
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <941> X-Ray Diffraction, ASTM E915 Verifying the alignment of X-ray diffraction instrumentation, ASTM D934 Identification of crystalline compounds in water-formed deposits

What is the Quantitative Phase Analysis X-Ray Diffractometer?

A quantitative phase analysis X-ray diffractometer is optimized for reliable, accurate phase proportions using Rietveld refinement or reference intensity ratios. It is chosen routinely for cement, minerals, catalysts and multiphase complex industrial materials.

What is the Quantitative Phase Analysis X-Ray Diffractometer?

A quantitative phase analysis X-ray diffractometer is optimized for reliable, accurate phase proportions using Rietveld refinement or reference intensity ratios. It is chosen routinely for cement, minerals, catalysts and multiphase complex industrial materials.

Overview

This configuration emphasizes the stability, resolution and software needed for reliable quantification. It typically includes a stable high-voltage generator, precise goniometer, low-background sample holders, optional spinner and incident-beam monochromator, and a detector with good linearity across a wide intensity range. Quantification uses full-pattern Rietveld refinement with known crystal structures, the internal standard method, or reference intensity ratios from calibrated standards. Amorphous content is determined by adding a crystalline internal standard such as corundum or zincite. Sample preparation controls particle size, packing and orientation, and instrument alignment and intensity calibration are verified with standards. The approach is standard in cement and clinker analysis, mineral processing, catalysts and multiphase industrial materials.

How does it work?

A focused X-ray beam, usually copper K-alpha radiation, strikes a powdered or polycrystalline sample. Crystal lattice planes scatter the beam, and constructive interference occurs at angles that satisfy Bragg's law, n times lambda equals two d sine theta. The detector records peak positions and intensities as the angle between the beam and the sample changes, producing a diffractogram. Peak positions reveal the lattice spacing and identify phases from reference databases, while peak intensities give relative phase amounts and peak widths relate to crystallite size and microstrain. Preferred orientation, sample displacement and fluorescence can distort results, so sample preparation and instrument alignment are critical. Modern instruments use theta-theta geometry, solid-state or position-sensitive detectors, and software for search-match, Rietveld refinement and profile analysis.

What are the key features?

  • Stable generator and precise goniometer
  • Low-background holders and spinner option
  • Detector with wide linear intensity range
  • Rietveld refinement with structural databases
  • Internal standard method for amorphous content
  • Intensity calibration with certified standards

What are the technical specifications?

A typical quantitative phase analysis x-ray diffractometer configuration offers 2-theta range of 5–120°, angular accuracy of ±0.01°, X-ray tube power of 1–3 kW, detector of solid-state with wide linear range, quantification methods of Rietveld, internal standard, RIR and amorphous determination of internal standard method. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Quantitative Phase Analysis X-Ray Diffractometer is used in cement and clinker phase quantification, mineral processing and ore mineralogy, catalyst phase composition and multiphase industrial and ceramic materials. Across the wider XRD class, laboratories also deploy it for pharmaceutical polymorph and crystallinity testing, cement, clinker and mineral phase analysis and catalyst, battery and ceramic materials.

Which standards and certifications apply?

Relevant standards and methods include USP <941> X-Ray Diffraction, ASTM E915 Verifying the alignment of X-ray diffraction instrumentation, ASTM D934 Identification of crystalline compounds in water-formed deposits, ISO 20203 Carbonaceous materials for aluminium production — XRD of calcined coke, ISO/IEC 17025 and IEC 61010-2-091. Certification candidates for this model are CE, Radiation safety enclosure and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

X-ray diffraction instruments are regulated radiation devices and require shielding, interlocks, radiation surveys and trained operators. Powder samples must be ground finely and packed reproducibly, because particle size, packing density and preferred orientation bias peak intensities; back-loading, side-loading or spinning stages reduce orientation effects. Sample fluorescence from iron, cobalt or manganese samples raises background with copper radiation, which may require an alternative wavelength or a monochromator. Alignment, zero-offset and instrument profile are verified with standards such as silicon or corundum. Detectors and X-ray tubes are wear items, and goniometer calibration should be checked periodically. Keep sample preparation records for method traceability.

How do I select the right Quantitative Phase Analysis X-Ray Diffractometer?

Select a quantification-optimized system when accurate phase proportions, including amorphous content, must be reported routinely, as in cement, minerals and catalysts. Specify the phases, expected proportions and required accuracy. Confirm software support for Rietveld, internal standard and reference intensity ratio methods, and plan standard-based intensity calibration.

How does it compare with other XRD variants?

Select a powder diffractometer by resolution, detector type, sample environment and throughput. Benchtop instruments are compact and easy to use for phase identification and routine QC but have lower resolution and fewer accessories. High-resolution research systems use long arms, monochromators and high-precision goniometers for accurate lattice parameters, quantitative analysis and complex profile fitting. In-situ systems add heating, cooling, humidity or gas stages for time-resolved studies. Micro-focus instruments provide small beams for inclusions and small samples. Transmission geometry suits weakly absorbing organic and pharmaceutical materials and can reduce preferred orientation. Confirm the 2-theta range, angular resolution, sample changer capacity and software features such as Rietveld and PDF database access for your application.

Full specifications

Full specifications
2-theta range5–120°
Angular accuracy±0.01°
X-ray tube power1–3 kW
Detectorsolid-state with wide linear range
Quantification methodsRietveld, internal standard, RIR
Amorphous determinationinternal standard method
Sample holderslow-background, spinning
Measurement time15–90 min per sample
Standardscertified intensity standards
InterfaceEthernet

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Cement and clinker phase quantification
  • Mineral processing and ore mineralogy
  • Catalyst phase composition
  • Multiphase industrial and ceramic materials

Key features

  • Stable generator and precise goniometer
  • Low-background holders and spinner option
  • Detector with wide linear intensity range
  • Rietveld refinement with structural databases
  • Internal standard method for amorphous content
  • Intensity calibration with certified standards

Frequently asked questions about Quantitative Phase Analysis X-Ray Diffractometer

A known amount of a crystalline internal standard, such as corundum or zincite, is added to the sample. Rietveld refinement determines the crystalline phases and the standard, and the difference from the weighed amount gives the amorphous fraction. Accurate weighing and homogeneous mixing are essential.