Key specifications

Key specifications
2-theta range0–160°
Angular resolution< 0.05° FWHM
X-ray tube power1–3 kW
Monochromatorincident-beam Ge or mirror
Goniometer radius240–320 mm
Detectorsolid-state or position-sensitive
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <941> X-Ray Diffraction, ASTM E915 Verifying the alignment of X-ray diffraction instrumentation, ASTM D934 Identification of crystalline compounds in water-formed deposits

What is the High-Resolution Powder X-Ray Diffractometer?

A high-resolution powder X-ray diffractometer uses a long arm, precise goniometer and monochromatic optics for accurate data. It is chosen for routine lattice parameters, Rietveld refinement and demanding critical quantitative phase analysis.

What is the High-Resolution Powder X-Ray Diffractometer?

A high-resolution powder X-ray diffractometer uses a long arm, precise goniometer and monochromatic optics for accurate data. It is chosen for routine lattice parameters, Rietveld refinement and demanding critical quantitative phase analysis.

Overview

This research-grade system combines a high-power X-ray tube, incident-beam monochromator or mirror optics, a high-precision goniometer with a long radius, and a solid-state or position-sensitive detector. The result is narrow, well-resolved peaks with low background, allowing accurate lattice parameters, crystallite size and strain analysis, and reliable Rietveld refinement of complex multiphase mixtures. Configurations include theta-theta or theta-2theta geometry, parallel-beam optics for irregular samples and capillary transmission for organics. Incident-beam monochromators remove K-beta and fluorescence, which is important for iron and cobalt-containing samples. Angular resolution, zero error and instrument profile are verified with certified standards. The system needs a stable foundation, water or air cooling and a controlled environment.

How does it work?

A focused X-ray beam, usually copper K-alpha radiation, strikes a powdered or polycrystalline sample. Crystal lattice planes scatter the beam, and constructive interference occurs at angles that satisfy Bragg's law, n times lambda equals two d sine theta. The detector records peak positions and intensities as the angle between the beam and the sample changes, producing a diffractogram. Peak positions reveal the lattice spacing and identify phases from reference databases, while peak intensities give relative phase amounts and peak widths relate to crystallite size and microstrain. Preferred orientation, sample displacement and fluorescence can distort results, so sample preparation and instrument alignment are critical. Modern instruments use theta-theta geometry, solid-state or position-sensitive detectors, and software for search-match, Rietveld refinement and profile analysis.

What are the key features?

  • High-power tube with incident-beam monochromator
  • Long-radius high-precision goniometer
  • Narrow peaks and low background
  • Accurate lattice parameter determination
  • Reliable Rietveld refinement of multiphase samples
  • Parallel-beam and capillary transmission options

What are the technical specifications?

A typical high-resolution powder x-ray diffractometer configuration offers 2-theta range of 0–160°, angular resolution of < 0.05° FWHM, X-ray tube power of 1–3 kW, monochromator of incident-beam Ge or mirror, goniometer radius of 240–320 mm and detector of solid-state or position-sensitive. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The High-Resolution Powder X-Ray Diffractometer is used in lattice parameter and crystallite size studies, quantitative phase analysis of multiphase materials, pharmaceutical crystalline form characterization and battery, catalyst and alloy phase research. Across the wider XRD class, laboratories also deploy it for pharmaceutical polymorph and crystallinity testing, cement, clinker and mineral phase analysis and catalyst, battery and ceramic materials.

Which standards and certifications apply?

Relevant standards and methods include USP <941> X-Ray Diffraction, ASTM E915 Verifying the alignment of X-ray diffraction instrumentation, ASTM D934 Identification of crystalline compounds in water-formed deposits, ISO 20203 Carbonaceous materials for aluminium production — XRD of calcined coke, ISO/IEC 17025 and IEC 61010-2-091. Certification candidates for this model are CE, Radiation safety enclosure and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

X-ray diffraction instruments are regulated radiation devices and require shielding, interlocks, radiation surveys and trained operators. Powder samples must be ground finely and packed reproducibly, because particle size, packing density and preferred orientation bias peak intensities; back-loading, side-loading or spinning stages reduce orientation effects. Sample fluorescence from iron, cobalt or manganese samples raises background with copper radiation, which may require an alternative wavelength or a monochromator. Alignment, zero-offset and instrument profile are verified with standards such as silicon or corundum. Detectors and X-ray tubes are wear items, and goniometer calibration should be checked periodically. Keep sample preparation records for method traceability.

How do I select the right High-Resolution Powder X-Ray Diffractometer?

Select a high-resolution system when accurate lattice parameters, crystallite size and strain, or robust Rietveld quantification are required, as in pharmaceutical, battery and advanced materials research. Specify the resolution, 2-theta range and sample stages needed, and confirm alignment and standards for performance verification.

How does it compare with other XRD variants?

Select a powder diffractometer by resolution, detector type, sample environment and throughput. Benchtop instruments are compact and easy to use for phase identification and routine QC but have lower resolution and fewer accessories. High-resolution research systems use long arms, monochromators and high-precision goniometers for accurate lattice parameters, quantitative analysis and complex profile fitting. In-situ systems add heating, cooling, humidity or gas stages for time-resolved studies. Micro-focus instruments provide small beams for inclusions and small samples. Transmission geometry suits weakly absorbing organic and pharmaceutical materials and can reduce preferred orientation. Confirm the 2-theta range, angular resolution, sample changer capacity and software features such as Rietveld and PDF database access for your application.

Full specifications

Full specifications
2-theta range0–160°
Angular resolution< 0.05° FWHM
X-ray tube power1–3 kW
Monochromatorincident-beam Ge or mirror
Goniometer radius240–320 mm
Detectorsolid-state or position-sensitive
Measurement time10–120 min per scan
Sample stagesreflection, capillary, spinning
Coolingwater or air
InterfaceEthernet

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Lattice parameter and crystallite size studies
  • Quantitative phase analysis of multiphase materials
  • Pharmaceutical crystalline form characterization
  • Battery, catalyst and alloy phase research

Key features

  • High-power tube with incident-beam monochromator
  • Long-radius high-precision goniometer
  • Narrow peaks and low background
  • Accurate lattice parameter determination
  • Reliable Rietveld refinement of multiphase samples
  • Parallel-beam and capillary transmission options

Frequently asked questions about High-Resolution Powder X-Ray Diffractometer

Rietveld refinement benefits from narrow, well-defined peaks, so a full width at half maximum below about 0.1 degrees and low background are desirable. Higher resolution improves the separation of overlapping reflections, which is important for low-symmetry or multiphase materials.