High-Resolution Powder X-Ray Diffractometer
高分辨率粉末 X 射线衍射仪
- SKU XRD-0002
- XRD
- CE (to be confirmed)
- Radiation safety enclosure (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| 2-theta range | 0–160° |
|---|---|
| Angular resolution | < 0.05° FWHM |
| X-ray tube power | 1–3 kW |
| Monochromator | incident-beam Ge or mirror |
| Goniometer radius | 240–320 mm |
| Detector | solid-state or position-sensitive |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <941> X-Ray Diffraction, ASTM E915 Verifying the alignment of X-ray diffraction instrumentation, ASTM D934 Identification of crystalline compounds in water-formed deposits
What is the High-Resolution Powder X-Ray Diffractometer?
A high-resolution powder X-ray diffractometer uses a long arm, precise goniometer and monochromatic optics for accurate data. It is chosen for routine lattice parameters, Rietveld refinement and demanding critical quantitative phase analysis.
What is the High-Resolution Powder X-Ray Diffractometer?
A high-resolution powder X-ray diffractometer uses a long arm, precise goniometer and monochromatic optics for accurate data. It is chosen for routine lattice parameters, Rietveld refinement and demanding critical quantitative phase analysis.
Overview
This research-grade system combines a high-power X-ray tube, incident-beam monochromator or mirror optics, a high-precision goniometer with a long radius, and a solid-state or position-sensitive detector. The result is narrow, well-resolved peaks with low background, allowing accurate lattice parameters, crystallite size and strain analysis, and reliable Rietveld refinement of complex multiphase mixtures. Configurations include theta-theta or theta-2theta geometry, parallel-beam optics for irregular samples and capillary transmission for organics. Incident-beam monochromators remove K-beta and fluorescence, which is important for iron and cobalt-containing samples. Angular resolution, zero error and instrument profile are verified with certified standards. The system needs a stable foundation, water or air cooling and a controlled environment.
How does it work?
A focused X-ray beam, usually copper K-alpha radiation, strikes a powdered or polycrystalline sample. Crystal lattice planes scatter the beam, and constructive interference occurs at angles that satisfy Bragg's law, n times lambda equals two d sine theta. The detector records peak positions and intensities as the angle between the beam and the sample changes, producing a diffractogram. Peak positions reveal the lattice spacing and identify phases from reference databases, while peak intensities give relative phase amounts and peak widths relate to crystallite size and microstrain. Preferred orientation, sample displacement and fluorescence can distort results, so sample preparation and instrument alignment are critical. Modern instruments use theta-theta geometry, solid-state or position-sensitive detectors, and software for search-match, Rietveld refinement and profile analysis.
What are the key features?
- High-power tube with incident-beam monochromator
- Long-radius high-precision goniometer
- Narrow peaks and low background
- Accurate lattice parameter determination
- Reliable Rietveld refinement of multiphase samples
- Parallel-beam and capillary transmission options
What are the technical specifications?
A typical high-resolution powder x-ray diffractometer configuration offers 2-theta range of 0–160°, angular resolution of < 0.05° FWHM, X-ray tube power of 1–3 kW, monochromator of incident-beam Ge or mirror, goniometer radius of 240–320 mm and detector of solid-state or position-sensitive. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The High-Resolution Powder X-Ray Diffractometer is used in lattice parameter and crystallite size studies, quantitative phase analysis of multiphase materials, pharmaceutical crystalline form characterization and battery, catalyst and alloy phase research. Across the wider XRD class, laboratories also deploy it for pharmaceutical polymorph and crystallinity testing, cement, clinker and mineral phase analysis and catalyst, battery and ceramic materials.
Which standards and certifications apply?
Relevant standards and methods include USP <941> X-Ray Diffraction, ASTM E915 Verifying the alignment of X-ray diffraction instrumentation, ASTM D934 Identification of crystalline compounds in water-formed deposits, ISO 20203 Carbonaceous materials for aluminium production — XRD of calcined coke, ISO/IEC 17025 and IEC 61010-2-091. Certification candidates for this model are CE, Radiation safety enclosure and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
X-ray diffraction instruments are regulated radiation devices and require shielding, interlocks, radiation surveys and trained operators. Powder samples must be ground finely and packed reproducibly, because particle size, packing density and preferred orientation bias peak intensities; back-loading, side-loading or spinning stages reduce orientation effects. Sample fluorescence from iron, cobalt or manganese samples raises background with copper radiation, which may require an alternative wavelength or a monochromator. Alignment, zero-offset and instrument profile are verified with standards such as silicon or corundum. Detectors and X-ray tubes are wear items, and goniometer calibration should be checked periodically. Keep sample preparation records for method traceability.
How do I select the right High-Resolution Powder X-Ray Diffractometer?
Select a high-resolution system when accurate lattice parameters, crystallite size and strain, or robust Rietveld quantification are required, as in pharmaceutical, battery and advanced materials research. Specify the resolution, 2-theta range and sample stages needed, and confirm alignment and standards for performance verification.
How does it compare with other XRD variants?
Select a powder diffractometer by resolution, detector type, sample environment and throughput. Benchtop instruments are compact and easy to use for phase identification and routine QC but have lower resolution and fewer accessories. High-resolution research systems use long arms, monochromators and high-precision goniometers for accurate lattice parameters, quantitative analysis and complex profile fitting. In-situ systems add heating, cooling, humidity or gas stages for time-resolved studies. Micro-focus instruments provide small beams for inclusions and small samples. Transmission geometry suits weakly absorbing organic and pharmaceutical materials and can reduce preferred orientation. Confirm the 2-theta range, angular resolution, sample changer capacity and software features such as Rietveld and PDF database access for your application.
Full specifications
| 2-theta range | 0–160° |
|---|---|
| Angular resolution | < 0.05° FWHM |
| X-ray tube power | 1–3 kW |
| Monochromator | incident-beam Ge or mirror |
| Goniometer radius | 240–320 mm |
| Detector | solid-state or position-sensitive |
| Measurement time | 10–120 min per scan |
| Sample stages | reflection, capillary, spinning |
| Cooling | water or air |
| Interface | Ethernet |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Lattice parameter and crystallite size studies
- Quantitative phase analysis of multiphase materials
- Pharmaceutical crystalline form characterization
- Battery, catalyst and alloy phase research
Key features
- High-power tube with incident-beam monochromator
- Long-radius high-precision goniometer
- Narrow peaks and low background
- Accurate lattice parameter determination
- Reliable Rietveld refinement of multiphase samples
- Parallel-beam and capillary transmission options
Frequently asked questions about High-Resolution Powder X-Ray Diffractometer
Rietveld refinement benefits from narrow, well-defined peaks, so a full width at half maximum below about 0.1 degrees and low background are desirable. Higher resolution improves the separation of overlapping reflections, which is important for low-symmetry or multiphase materials.
It removes K-beta radiation and reduces fluorescence from samples containing iron, cobalt or manganese, which would otherwise raise background with copper radiation. The cost is lower beam intensity and longer measurement times, but the improvement in peak-to-background ratio is often essential for accurate refinement.
Transmission geometry with a spinning capillary suits weakly absorbing organic and pharmaceutical powders, because it samples a larger volume and reduces preferred orientation and absorption effects. It also works well for very small sample amounts and for materials that must be sealed, such as air-sensitive compounds.
Grind the sample to a fine, uniform powder, then pack it into a holder by back-loading or side-loading so the surface is flat and level with the holder edge. Spinning or using a zero-background holder reduces preferred orientation and background. Preparation quality strongly affects relative peak intensities.
Plate-like or needle-like crystallites align when packed, so some lattice planes diffract more strongly than they should, distorting quantitative results. Gentle grinding, side-loading, spray drying and sample spinning reduce the effect. Rietveld refinement can model and correct residual orientation when the degree is known.
Quantitative phase analysis compares measured peak intensities with reference intensity ratios or applies full-pattern Rietveld refinement using known crystal structures. Rietveld is preferred for complex mixtures because it fits the whole pattern and accounts for overlap, background and preferred orientation. Accuracy depends on good sample preparation and structural models.
Related models