Online Multi-Parameter Water Quality Analyzer for Treatment Plants
水处理厂在线多参数水质分析仪
- SKU WQA-0005
- Water Quality Analyzers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- Chinese environmental monitoring instrument type approval (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Parameters | pH, conductivity, turbidity, free chlorine, temperature |
|---|---|
| pH range | 0–14 |
| Conductivity range | 0–2000 µS/cm |
| Turbidity range | 0–100 NTU |
| Free chlorine range | 0–5 mg/L |
| Sample flow | 200–500 mL/min |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 10523, ISO 7888, ISO 5814
What is the Online Multi-Parameter Water Quality Analyzer for Treatment Plants?
A panel-mounted analyzer that continuously measures pH, conductivity, turbidity, residual chlorine and temperature in a sample stream. It provides 4–20 mA and Modbus outputs for SCADA at drinking water plants, distribution points and industrial water systems where continuous supervision and alarms are required.
What is the Online Multi-Parameter Water Quality Analyzer for Treatment Plants?
A panel-mounted analyzer that continuously measures pH, conductivity, turbidity, residual chlorine and temperature in a sample stream. It provides 4–20 mA and Modbus outputs for SCADA at drinking water plants, distribution points and industrial water systems where continuous supervision and alarms are required.
Overview
This variant is a panel with a flow manifold holding pH, conductivity, turbidity, free or total chlorine and temperature sensors, plus a controller that handles calibration reminders, alarms and outputs. Sample flows at 200 to 500 mL/min through a constant-head overflow chamber to keep pressure stable and remove bubbles. Free chlorine is measured with an amperometric membrane or reagent-free polarographic sensor compensated for pH, and optional colorimetric DPD chlorine analyzers provide reference readings. Automatic cleaning with ultrasonic or brush systems reduces service frequency, typically to every two to four weeks. The analyzer logs data internally and outputs 4–20 mA, Modbus RTU and relay alarms, with the option for Ethernet and cloud telemetry. It supports distribution network monitoring, disinfection control and industrial cooling systems, but chlorine sensors need regular verification with DPD tests and membrane replacement every 3 to 12 months.
How does it work?
Water quality analyzers combine several sensor technologies in one instrument. pH is measured with a glass membrane electrode whose potential follows the Nernst equation. Conductivity uses a cell with two or four electrodes and temperature compensation to a 25 °C reference. Dissolved oxygen is sensed either by a polarographic or galvanic membrane sensor or, increasingly, by optical luminescence quenching of a dye. Turbidity is measured by nephelometry, detecting light scattered at 90° from an infrared or white source. Residual chlorine is determined amperometrically or by DPD colorimetry. A microprocessor applies calibration and temperature compensation, logs the readings and outputs them to a display, memory or digital network. Submersible and online designs add cleaning systems and housings for continuous deployment.
What are the key features?
- Panel-mounted flow manifold with pH, conductivity, turbidity, chlorine and temperature sensors
- Constant-head overflow chamber stabilizes pressure and removes bubbles
- Free chlorine measurement with pH compensation and DPD reference option
- Automatic ultrasonic or brush cleaning extends service intervals
- 4–20 mA, Modbus RTU and relay alarms with optional Ethernet telemetry
- Calibration reminders and data logging with event history
What are the technical specifications?
A typical online multi-parameter water quality analyzer for treatment plants configuration offers parameters of pH, conductivity, turbidity, free chlorine, temperature, pH range of 0–14, conductivity range of 0–2000 µS/cm, turbidity range of 0–100 NTU, free chlorine range of 0–5 mg/L and sample flow of 200–500 mL/min. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Online Multi-Parameter Water Quality Analyzer for Treatment Plants is used in drinking water plant finished water monitoring, distribution network residual chlorine tracking, swimming pool and cooling tower water control and industrial process water quality supervision. Across the wider Water Quality Analyzers class, laboratories also deploy it for drinking water treatment and distribution monitoring, river, lake and groundwater surveys and aquaculture dissolved oxygen and pH control.
Which standards and certifications apply?
Relevant standards and methods include ISO 10523, ISO 7888, ISO 5814, ISO 7027-1, ASTM D1293, ASTM D1125, ASTM D888, HJ 1147 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and Chinese environmental monitoring instrument type approval; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Calibrate pH with at least two buffers bracketing the sample range, conductivity with a standard near the expected value, and dissolved oxygen in water-saturated air or zero solution. Turbidity needs formazin or stabilized polymer standards. Rinse probes with deionized water between samples, store electrodes in the recommended solution and replace membranes, caps and reference fill on schedule. Biofouling on submersible sondes can ruin readings within days, so use wipers or copper guards and inspect regularly. Record calibration logs and sensor replacement dates for quality audits, and follow the method when results support regulatory reporting. Protect instruments from condensation, freezing and strong electromagnetic interference.
How do I select the right Online Multi-Parameter Water Quality Analyzer for Treatment Plants?
Select the online panel for continuous supervision of several core parameters at one sampling point, where alarms and SCADA integration are required. Use portable meters where spot checks suffice. In an RFQ, state parameters, ranges, sample flow and pressure, pipe connection, communication protocol, cleaning needs and the requirement for type-approved equipment.
How does it compare with other Water Quality Analyzers variants?
Begin by listing the parameters you must report and their ranges, since sensor selection sets cost and maintenance. Decide where the instrument will work: a benchtop meter for laboratory use, a handheld for spot checks, a submersible sonde for long-term deployment in rivers and lakes, or an online analyzer for treatment plants. Consider accuracy needs, for instance ± 0.01 pH for lab work versus ± 0.1 pH for field screening. Optical dissolved oxygen sensors need less maintenance than membrane types. Check the ingress protection rating, cable length, battery life and data logging capacity for field instruments. For online systems, evaluate automated cleaning and calibration options, and communication protocols. Finally compare sensor replacement costs and calibration solution requirements over the instrument's life.
Full specifications
| Parameters | pH, conductivity, turbidity, free chlorine, temperature |
|---|---|
| pH range | 0–14 |
| Conductivity range | 0–2000 µS/cm |
| Turbidity range | 0–100 NTU |
| Free chlorine range | 0–5 mg/L |
| Sample flow | 200–500 mL/min |
| Sample pressure | 0.05–0.5 MPa |
| Sample temperature | 2–45 °C |
| Outputs | 4–20 mA, RS-485 Modbus, relays |
| Power supply | AC 220 V, 50/60 Hz, 60 VA |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Drinking water plant finished water monitoring
- Distribution network residual chlorine tracking
- Swimming pool and cooling tower water control
- Industrial process water quality supervision
Key features
- Panel-mounted flow manifold with pH, conductivity, turbidity, chlorine and temperature sensors
- Constant-head overflow chamber stabilizes pressure and removes bubbles
- Free chlorine measurement with pH compensation and DPD reference option
- Automatic ultrasonic or brush cleaning extends service intervals
- 4–20 mA, Modbus RTU and relay alarms with optional Ethernet telemetry
- Calibration reminders and data logging with event history
Frequently asked questions about Online Multi-Parameter Water Quality Analyzer for Treatment Plants
Take a grab sample at the analyzer's sample line and measure free chlorine with a DPD photometer, comparing the result with the online reading. Adjust the online calibration if the difference exceeds the plant tolerance, typically ± 0.05 mg/L or ± 5%.
Expect a service visit every two to four weeks to check flow, clean the flow cell, verify calibration and refill electrolyte. Membranes, electrodes and lamps are replaced on an annual or shorter cycle depending on water quality and manufacturer advice.
Free chlorine exists as hypochlorous acid and hypochlorite, and amperometric sensors respond mainly to hypochlorous acid. The fraction changes strongly with pH, so sensors require a pH reading to compensate or buffered samples to report total free chlorine correctly.
Typical parameters are pH, conductivity, total dissolved solids, salinity, dissolved oxygen, turbidity, temperature and oxidation-reduction potential. Optional sensors add ammonium, nitrate, chlorophyll, blue-green algae, residual chlorine and depth, depending on the model.
A portable meter is held or dipped for spot measurements and displays readings immediately. A sonde is a submersible multi-sensor probe that logs data autonomously for days or weeks, resists biofouling and is used for continuous monitoring in rivers, lakes and tanks.
Dissolved oxygen indicates the capacity of water to support aquatic life and aerobic treatment. Levels below about 4 mg/L stress most fish, and aeration control in wastewater plants depends on it. It varies with temperature, salinity and pressure, so readings need compensation.
Related models