Manual Kinematic Viscosity Bath with Glass Capillary Viscometers
带玻璃毛细管粘度计的手动运动粘度恒温浴
- CE (to be confirmed)
- +1
Welcome to Lab Manufacturers China — laboratory instruments direct from a Chinese manufacturer

自动多管运动粘度测定仪
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
| Test method | ASTM D445, ASTM D446, ISO 3104 |
|---|---|
| Temperature range | 20–150 °C |
| Temperature stability | ±0.01 °C |
| Measuring positions | 2–4 tubes |
| Viscosity range | 0.5–30,000 mm²/s with tube set |
| Timing resolution | 0.01 s |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM D445, ISO 3104, ASTM D88
An automatic multi-tube kinematic viscometer times oil flow through several capillary viscometers with optical or ultrasonic sensors, calculates results and often cleans tubes automatically. It suits high-volume ASTM D445 laboratories in refineries, lubricant plants and independent testing facilities.
An automatic multi-tube kinematic viscometer times oil flow through several capillary viscometers with optical or ultrasonic sensors, calculates results and often cleans tubes automatically. It suits high-volume ASTM D445 laboratories in refineries, lubricant plants and independent testing facilities.
The automatic viscometer combines a precision thermostatic bath with two to four measuring positions, each with viscometer tubes of suitable ranges. Optical sensors, infrared or laser based, detect the meniscus as it passes the timing marks and record flow time to 0.01 seconds, eliminating stopwatch variation. Pumps or vacuum lines draw the sample above the timing mark and, in higher models, flush and dry tubes with solvent and air after each test, so one operator can run many samples. Software calculates kinematic viscosity from the tube constant, applies checks such as flow time limits and repeat agreement, and can compute viscosity index from results at two temperatures. Temperature stability of 0.01 to 0.02 °C is maintained by a circulator with a calibrated reference probe. Results can be sent to a LIMS. Higher cost is offset by labor savings and improved reproducibility.
Kinematic viscosity testers time the gravity-driven flow of a fixed liquid volume through a calibrated glass capillary viscometer held in a constant-temperature bath. Viscosity equals the measured flow time multiplied by the tube constant, expressed in mm²/s, and bath temperature must be held within about 0.02 °C because viscosity changes rapidly with temperature. Rotational instruments drive a spindle or rotor in the sample and measure the torque required, giving dynamic viscosity in mPa·s. Cold-cranking simulators rotate a rotor inside a stator at low temperature and relate motor speed to apparent viscosity for engine oils. Efflux cup methods such as Saybolt measure time for a set volume to drain through an orifice. Key components are the bath, thermostat, viscometer tubes, timing device and, in automatic models, optical or ultrasonic meniscus sensors.
A typical automatic multi-tube kinematic viscometer configuration offers test method of ASTM D445, ASTM D446, ISO 3104, temperature range of 20–150 °C, temperature stability of ±0.01 °C, measuring positions of 2–4 tubes, viscosity range of 0.5–30,000 mm²/s with tube set and timing resolution of 0.01 s. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
The Automatic Multi-Tube Kinematic Viscometer is used in refinery and blending plant QC, independent oil testing laboratories, used oil analysis and lubricant R&D. Across the wider Viscosity Testers class, laboratories also deploy it for lubricant viscosity grade verification, fuel oil and diesel specification testing and engine oil low-temperature grading.
Relevant standards and methods include ASTM D445, ISO 3104, ASTM D88, ASTM D2983, ASTM D5293, SAE J300, IP 71, GB/T 265 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 electrical safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Level the bath and keep it away from drafts and vibration, because temperature stability and tube verticality drive precision. Use certified viscosity reference standards to calibrate tubes and check the bath thermometer against a traceable reference at least annually. Filter or degas samples to remove particles and bubbles, and allow adequate thermal equilibration, usually 15 to 30 minutes. Clean viscometer tubes with suitable solvents and dry with filtered air so residue does not change the tube constant. Inspect glass for cracks or chips. Replace bath fluid at intervals recommended by the supplier. For rotational and cold-cranking instruments, verify torque and speed calibration with standard oils and keep cooling systems free of moisture build-up.
Select the automatic instrument for throughput above about 20 samples per day, traceable records or reduced operator dependence. It is more expensive than a manual bath. In an RFQ specify number of positions, viscosity ranges, temperatures, need for automatic cleaning, LIMS interface and supplied tube set.
Choose by the method named in your product specification. ASTM D445 capillary viscometry is the reference for kinematic viscosity of fuels and lubricants, and automatic multi-tube instruments raise throughput and remove timing subjectivity. Saybolt viscometers remain in use where legacy specifications are expressed in Saybolt seconds. Rotational instruments suit non-Newtonian or very viscous products and low-temperature lubricant tests, while cold-cranking simulators are specific to engine oil low-temperature grading under SAE J300. Consider the temperature range, from 40 and 100 °C for routine oils to -40 °C for low-temperature work, and confirm the bath can maintain stability. Check the tube range, sample volume, cleaning and drying arrangements, and calibration fluid availability. For large workloads, automatic cleaning stations and multi-position baths reduce labor considerably.
| Test method | ASTM D445, ASTM D446, ISO 3104 |
|---|---|
| Temperature range | 20–150 °C |
| Temperature stability | ±0.01 °C |
| Measuring positions | 2–4 tubes |
| Viscosity range | 0.5–30,000 mm²/s with tube set |
| Timing resolution | 0.01 s |
| Sample volume | About 10 mL per tube |
| Throughput | Up to 20 samples per hour with auto cleaning |
| Data output | USB, Ethernet, LIMS |
| Power supply | 220 V, 50 Hz, 2000 W |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Yes, provided the tubes, bath stability, temperature measurement and timing meet the method requirements and the instrument is verified with reference standards. The optical timing replaces the stopwatch, which the method permits when accuracy is shown.
After measurement, the instrument drains the sample, flushes the tube with a solvent such as toluene or heptane, and dries it with filtered air before the next sample. Waste solvent is collected, so solvent handling and ventilation should be planned.
Yes, but one bath normally holds one temperature at a time. Laboratories needing both temperatures continuously often install two baths or a dual-bath model, or change the set point between runs and allow equilibration.
Kinematic viscosity is the flow time of a liquid under gravity, expressed in mm²/s, and equals dynamic viscosity divided by density. Dynamic viscosity is the resistance to shear measured by torque in rotational instruments, expressed in mPa·s. Fuel and lubricant specifications commonly use kinematic values.
Viscosity of oils changes by several percent per degree Celsius, so even small temperature errors create large errors in results. ASTM D445 requires bath stability within 0.02 °C at 40 and 100 °C, which needs a well-stirred thermostat and a calibrated reference thermometer.
Viscosity index is calculated from kinematic viscosity at 40 and 100 °C using the equations in ASTM D2270. A higher index means viscosity changes less with temperature. Lubricant suppliers report it to describe how oil behaves between cold start and operating temperature.