Automated Clinical Chemistry Analyzer for Toxicology and Therapeutic Drug Monitoring
毒理学和治疗药物监测用自动临床化学分析仪
- SKU TOX-0005
- Toxicology Analyzers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Throughput | 200–800 tests/h |
|---|---|
| Method | Photometry, turbidimetry, immunoassay |
| Sample types | Serum, plasma, urine |
| Sample volume | 2–35 µL |
| Reaction temperature | 37 °C |
| Wavelength range | 340–800 nm |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ANSI/ASB Standard 036, ISO 15189, ISO/IEC 17025
What is the Automated Clinical Chemistry Analyzer for Toxicology and Therapeutic Drug Monitoring?
An automated clinical chemistry analyzer for toxicology runs immunoassays and photometric tests for therapeutic drugs, paracetamol, salicylate and alcohol on serum and plasma. It supports emergency toxicology and drug level monitoring. It suits hospital laboratories.
What is the Automated Clinical Chemistry Analyzer for Toxicology and Therapeutic Drug Monitoring?
An automated clinical chemistry analyzer for toxicology runs immunoassays and photometric tests for therapeutic drugs, paracetamol, salicylate and alcohol on serum and plasma. It supports emergency toxicology and drug level monitoring. It suits hospital laboratories.
Overview
This random-access analyzer performs photometric, turbidimetric and immunoassay tests in a single platform. Toxicology menus commonly include paracetamol, salicylate, ethanol, lithium, digoxin, vancomycin and anticonvulsants. Samples and reagents are pipetted into reaction cuvettes, incubated at 37 °C and measured with a monochromator or filter photometer, with throughputs of 200 to 800 tests per hour. Results in minutes help clinicians decide on treatment in poisoning cases, including antidote administration guided by paracetamol level. Calibration curves are stored, and QC rules such as Westgard alert operators to drift. The platform is less specific than mass spectrometry and does not cover unknown compounds, so it complements a confirmatory method. Connectivity to hospital systems supports rapid result delivery.
How does it work?
Toxicology analyzers use several principles. Immunoassay analyzers detect drug classes through antibody binding and photometric or chemiluminescent signals, providing fast presumptive results. Gas chromatography with headspace sampling separates volatile compounds such as ethanol and detects them by flame ionization. GC-MS and LC-MS/MS separate compounds and identify them by mass spectra or specific ion transitions, giving confirmatory quantitation with isotope-labeled internal standards. Inductively coupled plasma mass spectrometry ionizes samples in argon plasma to measure metals at ng/L levels. Sample preparation steps such as protein precipitation, hydrolysis, liquid-liquid or solid-phase extraction remove interferences and improve sensitivity. Calibration, quality controls and proficiency testing are required to report results that stand up in clinical and legal settings.
What are the key features?
- Random-access platform for photometric and immunoassay tests
- Menu includes paracetamol, salicylate, ethanol and common drugs
- Throughput of 200 to 800 tests per hour
- Stored calibration curves and Westgard QC rules
- Connectivity to hospital information systems
What are the technical specifications?
A typical automated clinical chemistry analyzer for toxicology and therapeutic drug monitoring configuration offers throughput of 200–800 tests/h, method of Photometry, turbidimetry, immunoassay, sample types of Serum, plasma, urine, sample volume of 2–35 µL, reaction temperature of 37 °C and wavelength range of 340–800 nm. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automated Clinical Chemistry Analyzer for Toxicology and Therapeutic Drug Monitoring is used in emergency toxicology, therapeutic drug monitoring, overdose triage and hospital central laboratories. Across the wider Toxicology Analyzers class, laboratories also deploy it for clinical toxicology and poisoning cases, forensic post-mortem toxicology and workplace and driving-related testing.
Which standards and certifications apply?
Relevant standards and methods include ANSI/ASB Standard 036, ISO 15189, ISO/IEC 17025, CLSI C62 and CLSI EP15. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Validate each method for selectivity, accuracy, precision, carryover, matrix effects and stability, following recognized forensic or clinical toxicology guidance. Use certified reference materials, matrix-matched calibrators and independent quality controls, and participate in proficiency testing. Control carryover with blanks after high samples. Install instruments with stable power, gas purity, temperature and ventilation appropriate to solvents and acids used. Follow biosafety practices when handling blood and urine. Maintain sample retention and chain-of-custody records, and secure data with audit trails. Perform preventive maintenance on sources, columns, pumps and sample introduction systems, and document measurement uncertainty for quantitative results.
How do I select the right Automated Clinical Chemistry Analyzer for Toxicology and Therapeutic Drug Monitoring?
Select this analyzer when speed and integration with a clinical laboratory workflow are priorities. Confirmatory needs require MS methods. In an RFQ, specify the assay menu, throughput, sample types, reagent supply, LIS protocol and QC software.
How does it compare with other Toxicology Analyzers variants?
Choose by the question being asked and the required evidence level. Immunoassay analyzers give rapid presumptive results for common drug classes and suit high-volume screening. Headspace GC is the dedicated method for blood alcohol and volatile substances. LC-MS/MS is chosen for broad, sensitive confirmatory panels including therapeutic drugs and new substances, while GC-MS remains strong for volatile and derivatizable compounds. ICP-MS is required when metals and metalloids are the targets. Consider sample volume, matrix, turnaround time, automation level and staff expertise. Check calibration and QC software, LIS connectivity and the availability of validated assay kits. For forensic use, confirm data integrity features, chain-of-custody support and method validation documentation.
Full specifications
| Throughput | 200–800 tests/h |
|---|---|
| Method | Photometry, turbidimetry, immunoassay |
| Sample types | Serum, plasma, urine |
| Sample volume | 2–35 µL |
| Reaction temperature | 37 °C |
| Wavelength range | 340–800 nm |
| Reagent positions | ≥ 40 |
| Result time | 5–15 min |
| Interface | LIS / HIS bidirectional |
| Power supply | 220 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Emergency toxicology
- Therapeutic drug monitoring
- Overdose triage
- Hospital central laboratories
Key features
- Random-access platform for photometric and immunoassay tests
- Menu includes paracetamol, salicylate, ethanol and common drugs
- Throughput of 200 to 800 tests per hour
- Stored calibration curves and Westgard QC rules
- Connectivity to hospital information systems
Frequently asked questions about Automated Clinical Chemistry Analyzer for Toxicology and Therapeutic Drug Monitoring
No. It measures defined analytes using validated assays, so unknown or unusual compounds require broad screening by mass spectrometry. Confirmation is then needed.
Treatment decisions for paracetamol overdose depend on serum level and time since ingestion, so a rapid result guides antidote administration and can prevent liver damage.
Internal QC runs with each batch, with Westgard rules flagging drift, and external quality assessment schemes compare results with peer laboratories.
A toxicology analyzer is an instrument that detects and quantifies drugs, poisons, alcohol or metals in biological samples. Options include immunoassay analyzers for screening and chromatography-mass spectrometry or ICP-MS systems for confirmation and quantitation.
Immunoassays detect drug classes through antibody cross-reactivity, so they can give false positives. A mass spectrometry confirmation identifies and quantifies the specific compound, which is essential for clinical decisions and legal use.
Blood alcohol is commonly measured by headspace gas chromatography with flame ionization detection. The sample is heated in a sealed vial and the vapor is injected, using an internal standard such as n-propanol.