Automated Immunoassay Toxicology Analyzer
自动免疫分析毒理学分析仪
- SKU TOX-0003
- Toxicology Analyzers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Throughput | 200–1200 tests/h |
|---|---|
| Method | Homogeneous enzyme immunoassay / KIMS |
| Sample types | Urine, serum |
| Sample volume | 2–20 µL |
| Assay menu | ≥ 10 drug classes |
| Result type | Qualitative / semi-quantitative |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ANSI/ASB Standard 036, ISO 15189, ISO/IEC 17025
What is the Automated Immunoassay Toxicology Analyzer?
An automated immunoassay toxicology analyzer runs homogeneous enzyme or particle immunoassays on urine and serum to give presumptive drug class results. It is chosen for high-volume screening in hospital, workplace and forensic laboratories.
What is the Automated Immunoassay Toxicology Analyzer?
An automated immunoassay toxicology analyzer runs homogeneous enzyme or particle immunoassays on urine and serum to give presumptive drug class results. It is chosen for high-volume screening in hospital, workplace and forensic laboratories.
Overview
This benchtop or floor-standing analyzer automates sample pipetting, reagent mixing, incubation and photometric measurement. Homogeneous enzyme immunoassays or kinetic interaction of microparticles in solution (KIMS) measure the change in absorbance proportional to drug concentration. Assays cover amphetamines, opiates, cocaine metabolite, cannabinoids, benzodiazepines, methadone, fentanyl and others, with cut-offs set by the laboratory. Throughput ranges from 200 to 1200 tests per hour. Qualitative or semi-quantitative results are produced with reference to a cutoff calibrator, and controls verify performance. Antibody cross-reactivity means positives are presumptive and need confirmation by mass spectrometry. Connectivity to a LIS and barcode reading of samples reduce transcription errors and support chain of custody.
How does it work?
Toxicology analyzers use several principles. Immunoassay analyzers detect drug classes through antibody binding and photometric or chemiluminescent signals, providing fast presumptive results. Gas chromatography with headspace sampling separates volatile compounds such as ethanol and detects them by flame ionization. GC-MS and LC-MS/MS separate compounds and identify them by mass spectra or specific ion transitions, giving confirmatory quantitation with isotope-labeled internal standards. Inductively coupled plasma mass spectrometry ionizes samples in argon plasma to measure metals at ng/L levels. Sample preparation steps such as protein precipitation, hydrolysis, liquid-liquid or solid-phase extraction remove interferences and improve sensitivity. Calibration, quality controls and proficiency testing are required to report results that stand up in clinical and legal settings.
What are the key features?
- Automated pipetting, incubation and photometric reading
- Assay menu covering common drug classes with laboratory-set cutoffs
- Throughput from 200 to 1200 tests per hour
- Barcode sample reading and LIS connectivity
- Calibration and QC tracking with Levey-Jennings charts
What are the technical specifications?
A typical automated immunoassay toxicology analyzer configuration offers throughput of 200–1200 tests/h, method of Homogeneous enzyme immunoassay / KIMS, sample types of Urine, serum, sample volume of 2–20 µL, assay menu of ≥ 10 drug classes and result type of Qualitative / semi-quantitative. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automated Immunoassay Toxicology Analyzer is used in urine drug screening, hospital emergency toxicology, workplace testing programs and pain management monitoring. Across the wider Toxicology Analyzers class, laboratories also deploy it for clinical toxicology and poisoning cases, forensic post-mortem toxicology and workplace and driving-related testing.
Which standards and certifications apply?
Relevant standards and methods include ANSI/ASB Standard 036, ISO 15189, ISO/IEC 17025, CLSI C62 and CLSI EP15. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Validate each method for selectivity, accuracy, precision, carryover, matrix effects and stability, following recognized forensic or clinical toxicology guidance. Use certified reference materials, matrix-matched calibrators and independent quality controls, and participate in proficiency testing. Control carryover with blanks after high samples. Install instruments with stable power, gas purity, temperature and ventilation appropriate to solvents and acids used. Follow biosafety practices when handling blood and urine. Maintain sample retention and chain-of-custody records, and secure data with audit trails. Perform preventive maintenance on sources, columns, pumps and sample introduction systems, and document measurement uncertainty for quantitative results.
How do I select the right Automated Immunoassay Toxicology Analyzer?
Select an immunoassay analyzer for rapid, high-volume screening with presumptive results and confirm positives by LC-MS/MS or GC-MS. In an RFQ, specify assay menu, cutoffs, throughput, reagent availability, LIS interface and quality control features. Also confirm reagent supply continuity.
How does it compare with other Toxicology Analyzers variants?
Choose by the question being asked and the required evidence level. Immunoassay analyzers give rapid presumptive results for common drug classes and suit high-volume screening. Headspace GC is the dedicated method for blood alcohol and volatile substances. LC-MS/MS is chosen for broad, sensitive confirmatory panels including therapeutic drugs and new substances, while GC-MS remains strong for volatile and derivatizable compounds. ICP-MS is required when metals and metalloids are the targets. Consider sample volume, matrix, turnaround time, automation level and staff expertise. Check calibration and QC software, LIS connectivity and the availability of validated assay kits. For forensic use, confirm data integrity features, chain-of-custody support and method validation documentation.
Full specifications
| Throughput | 200–1200 tests/h |
|---|---|
| Method | Homogeneous enzyme immunoassay / KIMS |
| Sample types | Urine, serum |
| Sample volume | 2–20 µL |
| Assay menu | ≥ 10 drug classes |
| Result type | Qualitative / semi-quantitative |
| Reagent capacity | ≥ 40 positions |
| Wavelength range | 340–800 nm |
| Interface | LIS bidirectional |
| Power supply | 220 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Urine drug screening
- Hospital emergency toxicology
- Workplace testing programs
- Pain management monitoring
Key features
- Automated pipetting, incubation and photometric reading
- Assay menu covering common drug classes with laboratory-set cutoffs
- Throughput from 200 to 1200 tests per hour
- Barcode sample reading and LIS connectivity
- Calibration and QC tracking with Levey-Jennings charts
Frequently asked questions about Automated Immunoassay Toxicology Analyzer
Antibodies can cross-react with related compounds, so a positive indicates a drug class rather than a specific drug. Confirmation by mass spectrometry is needed for clinical or legal decisions.
Cutoffs follow regulatory or program requirements, such as workplace or clinical guidelines, and are set and verified by the laboratory with calibrators and controls.
Some analyzers support user-defined assays on open channels, which allows additional drug panels, but the laboratory must validate these assays before use.
A toxicology analyzer is an instrument that detects and quantifies drugs, poisons, alcohol or metals in biological samples. Options include immunoassay analyzers for screening and chromatography-mass spectrometry or ICP-MS systems for confirmation and quantitation.
Immunoassays detect drug classes through antibody cross-reactivity, so they can give false positives. A mass spectrometry confirmation identifies and quantifies the specific compound, which is essential for clinical decisions and legal use.
Blood alcohol is commonly measured by headspace gas chromatography with flame ionization detection. The sample is heated in a sealed vial and the vapor is injected, using an internal standard such as n-propanol.