Automated Immunoassay Urine Drug Screening Analyzer
自动免疫分析尿液毒品筛查分析仪
- SKU DSS-0001
- Drug Screening Systems
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Throughput | 400–1200 tests/h |
|---|---|
| Method | Homogeneous enzyme immunoassay |
| Sample type | Urine |
| Sample volume | 2–10 µL |
| Drug menu | ≥ 12 drug classes |
| Result type | Qualitative / semi-quantitative |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI EP12, ISO 18113-1
What is the Automated Immunoassay Urine Drug Screening Analyzer?
An automated immunoassay urine drug screening analyzer runs multi-drug panels on urine samples with minimal operator input. It is designed for central laboratories and treatment programs that screen hundreds of samples per day against defined cutoffs.
What is the Automated Immunoassay Urine Drug Screening Analyzer?
An automated immunoassay urine drug screening analyzer runs multi-drug panels on urine samples with minimal operator input. It is designed for central laboratories and treatment programs that screen hundreds of samples per day against defined cutoffs.
Overview
This analyzer automates pipetting, reagent addition, incubation and photometric measurement using homogeneous immunoassay chemistry. Random-access operation allows different drug panels per sample, with panels typically covering amphetamines, methamphetamine, opiates, cocaine metabolite, THC metabolite, benzodiazepines, methadone, barbiturates and fentanyl. Cutoffs are selected per assay, and semi-quantitative results are obtained from a calibration curve to support cutoff verification. Throughput ranges from 400 to 1200 tests per hour. Integrated specimen validity tests can measure creatinine, pH and oxidants to detect dilution or adulteration. Barcode reading and LIS connectivity maintain sample identity and reduce transcription errors. Reagent onboard stability and calibration frequency should be evaluated, as they affect running costs and the amount of QC material consumed.
How does it work?
Most drug screening relies on competitive immunoassay. A labeled drug or drug-conjugate competes with drug in the sample for a limited number of antibody binding sites, so the signal is inversely related to the drug concentration. In lateral flow cassettes, the sample migrates along a nitrocellulose membrane and a colored line appears in the test region when drug is absent or below the cutoff. Readers use a camera or photodiode to interpret line intensity and remove visual subjectivity. Instrument immunoassays use enzyme-labeled or particle-enhanced reactions measured photometrically, and ELISA plates measure enzyme-generated color in wells with a microplate reader. Each assay is set to a cutoff concentration, for example 300 or 50 ng/mL depending on the drug, and results are presumptive until confirmed by GC-MS or LC-MS/MS.
What are the key features?
- Random-access drug panels with selectable cutoffs
- Throughput of 400 to 1200 tests per hour
- Specimen validity tests for creatinine, pH and oxidants
- Barcode sample reading and bidirectional LIS link
- Onboard calibration and QC tracking with alerts
What are the technical specifications?
A typical automated immunoassay urine drug screening analyzer configuration offers throughput of 400–1200 tests/h, method of Homogeneous enzyme immunoassay, sample type of Urine, sample volume of 2–10 µL, drug menu of ≥ 12 drug classes and result type of Qualitative / semi-quantitative. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automated Immunoassay Urine Drug Screening Analyzer is used in central laboratory urine screening, treatment program monitoring, workplace program laboratories and probation and court programs. Across the wider Drug Screening Systems class, laboratories also deploy it for workplace drug testing programs, clinical and emergency department screening and drug treatment and probation monitoring.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, CLSI EP12, ISO 18113-1, IEC 61010-2-101 and SAMHSA Mandatory Guidelines for Federal Workplace Drug Testing Programs. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Follow the manufacturer instructions for specimen collection, volume and read time, because reading outside the window can change the result. Store reagents and cassettes within the labeled temperature range and do not use them after expiry. Run positive and negative controls at defined intervals and record lot numbers. Maintain chain-of-custody and specimen integrity checks such as temperature, creatinine and adulterant testing for urine. Clean readers and optical windows, and verify calibration as specified. Because results are presumptive, define a confirmation pathway with a qualified laboratory and communicate cross-reactivity limits to reviewers. Keep personal data secure according to privacy rules applicable to testing programs.
How do I select the right Automated Immunoassay Urine Drug Screening Analyzer?
Choose this analyzer for centralized, high-volume urine screening where consistency, LIS integration and validity testing matter. For small sites, a reader with cassettes is cheaper. In an RFQ, specify the required drug menu, cutoffs, throughput, validity tests and LIS protocol.
How does it compare with other Drug Screening Systems variants?
Choose according to testing volume, setting and required evidence. Low-volume sites such as clinics and clubs often use instant cassettes or cups with a reader, while a central laboratory screening hundreds of samples a day needs an automated immunoassay analyzer. Oral fluid systems suit roadside and workplace testing where observed collection matters, and hair testing offers a long detection window. Check the drug panel, cutoff values, specimen types and cross-reactivity data. A reader reduces subjectivity and supports record-keeping, which is important for workplace programs. Consider connectivity with LIS or case management software, the cost of consumables, reagent stability and storage conditions. Programs following regulated guidelines must confirm that cutoffs and procedures match the required scheme.
Full specifications
| Throughput | 400–1200 tests/h |
|---|---|
| Method | Homogeneous enzyme immunoassay |
| Sample type | Urine |
| Sample volume | 2–10 µL |
| Drug menu | ≥ 12 drug classes |
| Result type | Qualitative / semi-quantitative |
| Validity tests | Creatinine, pH, oxidants |
| Reagent positions | ≥ 40 |
| Interface | LIS bidirectional |
| Power supply | 220 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Central laboratory urine screening
- Treatment program monitoring
- Workplace program laboratories
- Probation and court programs
Key features
- Random-access drug panels with selectable cutoffs
- Throughput of 400 to 1200 tests per hour
- Specimen validity tests for creatinine, pH and oxidants
- Barcode sample reading and bidirectional LIS link
- Onboard calibration and QC tracking with alerts
Frequently asked questions about Automated Immunoassay Urine Drug Screening Analyzer
Typical throughput is 400 to 1200 tests per hour, which equals screening around 50 to 150 samples per hour with a panel of eight drugs, depending on the model and assay menu.
Creatinine, pH and oxidant checks reveal dilution, substitution or adulteration of urine. A specimen failing validity tests is flagged before it is reported as negative.
Many assays offer more than one cutoff, but changes must match the program requirement and be verified with calibrators and controls at the new cutoff before use.
A drug screening system is a set of instruments and tests that quickly detect drugs of abuse in specimens such as urine or oral fluid. Most use immunoassay at defined cutoffs and give presumptive results that need laboratory confirmation.
Accuracy is high for the target drug at its cutoff but not absolute. Cross-reactivity can cause false positives and low concentrations near the cutoff can give false negatives, so confirmation by GC-MS or LC-MS/MS is standard.
A cutoff is the concentration at or above which a test reports positive. It is set by regulation or program design and differs by drug and specimen, for example 50 ng/mL for some opiates in urine.
Related models