Bead Mill Tissue Homogenizer
珠磨式组织匀浆仪
- SKU TIH-0001
- Tissue Homogenizers
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Oscillation speed | 4–6.5 m/s |
|---|---|
| Tube capacity | 2–24 × 2 mL tubes |
| Sample volume per tube | 0.1–1 mL |
| Bead size range | 0.1–3 mm |
| Cycle time | 10–300 s |
| Programs | Up to 20 stored |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-051, ISO 6887-1
What is the Bead Mill Tissue Homogenizer?
A bead mill tissue homogenizer shakes sealed tubes containing sample and beads at high speed so collisions rupture the tissue. It processes 2 to 24 samples at once and is widely used for DNA, RNA and protein extraction from animal, plant and microbial samples.
What is the Bead Mill Tissue Homogenizer?
A bead mill tissue homogenizer shakes sealed tubes containing sample and beads at high speed so collisions rupture the tissue. It processes 2 to 24 samples at once and is widely used for DNA, RNA and protein extraction from animal, plant and microbial samples.
Overview
The bead mill holds sealed 2 mL tubes, or larger tubes up to 15 mL, in a rack that oscillates horizontally or in a figure-eight pattern at 4 to 6.5 m/s. Ceramic, glass or steel beads of 0.1 to 3 mm impact the sample, breaking cell walls and tissue. Typical cycles are 20 to 120 seconds, with pauses to avoid heating. Racks hold 2 to 24 tubes, and some models process 48 tubes in a plate format. Speed and time are set on a display, and programs can be stored. The closed-tube format prevents cross-contamination and aerosol release, which suits infectious samples and PCR workflows. Bead mills handle soft tissue, tough tissue such as skin and muscle, bacteria, yeast, spores and plant material. Noise is high, 70 to 85 dB(A), and an enclosed chamber with lid interlock is standard.
How does it work?
Tissue homogenizers apply mechanical force to rupture tissue structure and cell walls. Bead mills shake sealed tubes containing the sample and ceramic, glass or steel beads at high speed, typically 4 to 7 m/s, so that collisions crush and shear the tissue. Motorized Potter-Elvehjem homogenizers rotate a close-fitting pestle inside a glass tube at 200 to 2,000 rpm, forcing tissue through a narrow clearance of 0.1 to 0.15 mm. Cryogenic grinders use a magnetic impactor in liquid-nitrogen-cooled vials to pulverize brittle frozen tissue. Paddle blenders use reciprocating paddles to press and release material in a sterile bag. Key components are a drive unit, a vessel or tube, the grinding element such as beads or pestle, and a cooling or cryogenic system to preserve labile biomolecules.
What are the key features?
- Sealed-tube processing avoids cross-contamination and aerosols
- Oscillation speed of about 4–6.5 m/s for effective bead impact
- Racks for 2–24 tubes of 2 mL, with larger-tube adapters
- Programmable time, speed and cycle count with stored methods
- Lid interlock and enclosed chamber for user safety
- Handles soft tissue, tough tissue, microbes and plant material
What are the technical specifications?
A typical bead mill tissue homogenizer configuration offers oscillation speed of 4–6.5 m/s, tube capacity of 2–24 × 2 mL tubes, sample volume per tube of 0.1–1 mL, bead size range of 0.1–3 mm, cycle time of 10–300 s and programs of Up to 20 stored. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Bead Mill Tissue Homogenizer is used in DNA and RNA extraction, protein extraction, microbial cell lysis, plant tissue preparation and forensic sample processing. Across the wider Tissue Homogenizers class, laboratories also deploy it for DNA and RNA extraction from tissue, protein and enzyme extraction and plant and seed sample preparation.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-051, ISO 6887-1, ISO 7218 and GB 4789.1. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Keep tissue cold and process quickly to preserve RNA, proteins and enzyme activity; add stabilizing buffers where appropriate. Load tubes symmetrically in bead mills and do not exceed the rated tube fill volume, which is usually half of the tube. Select bead size and material to match tissue hardness, and avoid contamination with metals if trace element analysis follows. Follow the supplier's method for each tissue type, and validate homogenization efficiency against a reference method. For infectious or biohazardous material, use sealed tubes and work in a biosafety cabinet. Clean glass homogenizers thoroughly, and handle liquid nitrogen with protective equipment. Comply with IEC 61010-1 and local biosafety rules.
How do I select the right Bead Mill Tissue Homogenizer?
Choose a bead mill for multi-sample tissue and microbial lysis in sealed tubes. Use a Potter-Elvehjem homogenizer for gentle organelle-preserving work, and a cryogenic grinder for hard brittle samples. In the RFQ, specify tube sizes, number of samples, bead types, speed and cooling.
How does it compare with other Tissue Homogenizers variants?
Choose a tissue homogenizer by sample type, throughput, sample size and downstream analysis. Bead mills handle soft and tough tissues, microbes and plant material in sealed tubes, and are the usual choice for high throughput with 24 or more samples at once. Choose cryogenic cooling for RNA and labile metabolites. Potter-Elvehjem homogenizers give gentle, reproducible disruption of soft tissue such as liver and brain, preserving organelles. Cryogenic grinders pulverize very hard or brittle samples such as bone and seeds. Paddle blenders suit food and microbiology samples of 10 to 400 mL. Check tube volumes, bead types, speed control, cooling and aerosol containment. For regulated testing, consider cross-contamination prevention and documented cleaning steps. Confirm noise, vibration and safety interlocks.
Full specifications
| Oscillation speed | 4–6.5 m/s |
|---|---|
| Tube capacity | 2–24 × 2 mL tubes |
| Sample volume per tube | 0.1–1 mL |
| Bead size range | 0.1–3 mm |
| Cycle time | 10–300 s |
| Programs | Up to 20 stored |
| Oscillation pattern | Horizontal or figure-eight |
| Noise level | 70–85 dB(A) |
| Safety | Lid interlock |
| Power supply | 100–240 V, 50/60 Hz |
| Dimensions (W×D×H) | 350 × 400 × 300 mm |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- DNA and RNA extraction
- Protein extraction
- Microbial cell lysis
- Plant tissue preparation
- Forensic sample processing
Key features
- Sealed-tube processing avoids cross-contamination and aerosols
- Oscillation speed of about 4–6.5 m/s for effective bead impact
- Racks for 2–24 tubes of 2 mL, with larger-tube adapters
- Programmable time, speed and cycle count with stored methods
- Lid interlock and enclosed chamber for user safety
- Handles soft tissue, tough tissue, microbes and plant material
Frequently asked questions about Bead Mill Tissue Homogenizer
Use 0.1 mm glass or zirconia beads for bacteria and yeast, 1 to 2 mm for tissue, and 2.8 mm or steel beads for tough tissue. Follow the supplier's recommendation and optimize for your sample.
Use short cycles with rest intervals, pre-chill tubes and racks, or choose a model with cooling. Heat degrades RNA and proteins and should be kept to a minimum.
Sealed tubes limit aerosol release, but you must still follow your biosafety rules. Open tubes only in a biosafety cabinet and decontaminate beads and racks appropriately.
A tissue homogenizer breaks tissue into uniform suspensions or lysates by bead impact, grinding, pestle shear or paddle action. It prepares samples for DNA, RNA, protein and metabolite analysis in life science, clinical and food laboratories.
Bead mills with cooling and cryogenic grinders protect RNA by keeping samples cold and processing quickly. Use RNase-free tubes and lysis buffer that inactivates nucleases immediately.
A bead mill shakes sealed tubes with beads and handles many samples, while a rotor-stator probe is immersed in each sample. Bead mills avoid cross-contamination, whereas probes handle larger volumes.