High-Throughput Bead Mill with Cryogenic Cooling
带冷冻冷却的高通量珠磨仪
- SKU TIH-0002
- Tissue Homogenizers
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Oscillation speed | 6–8 m/s |
|---|---|
| Sample capacity | 48–96 tubes or plates |
| Tube size | 1.4–2 mL |
| Chamber temperature | -20 to -80 °C |
| Cooling method | Liquid nitrogen vapor or cold gas |
| Cycle time | 30–120 s |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-051, ISO 6887-1
What is the High-Throughput Bead Mill with Cryogenic Cooling?
A high-throughput bead mill with cryogenic cooling pairs plate- or rack-format bead beating with liquid nitrogen or cold-gas cooling. It processes 48 to 96 samples at temperatures down to -80 °C and is suited to RNA and metabolite work in large studies.
What is the High-Throughput Bead Mill with Cryogenic Cooling?
A high-throughput bead mill with cryogenic cooling pairs plate- or rack-format bead beating with liquid nitrogen or cold-gas cooling. It processes 48 to 96 samples at temperatures down to -80 °C and is suited to RNA and metabolite work in large studies.
Overview
This variant adds a cooling system to the bead mill so that samples stay cold during homogenization. Liquid nitrogen vapor or a cold nitrogen gas stream holds the chamber at -20 to -80 degrees C, and racks process 48 to 96 tubes of 1.4 to 2 mL, or deep-well plates. Oscillation speeds reach 6 to 8 m/s, and the cycle time per batch is typically 30 to 120 seconds, so a full plate can be prepared in a few minutes. Cooling protects RNA integrity, enzyme activity and labile metabolites and metabolomic profiles. An automated liquid nitrogen feed and temperature sensor control the chamber, with safety shutoff for oxygen depletion and overpressure. The system is used in clinical studies, biobanking, metabolomics and plant genomics where hundreds of samples must be processed consistently. It requires a liquid nitrogen supply and trained users.
How does it work?
Tissue homogenizers apply mechanical force to rupture tissue structure and cell walls. Bead mills shake sealed tubes containing the sample and ceramic, glass or steel beads at high speed, typically 4 to 7 m/s, so that collisions crush and shear the tissue. Motorized Potter-Elvehjem homogenizers rotate a close-fitting pestle inside a glass tube at 200 to 2,000 rpm, forcing tissue through a narrow clearance of 0.1 to 0.15 mm. Cryogenic grinders use a magnetic impactor in liquid-nitrogen-cooled vials to pulverize brittle frozen tissue. Paddle blenders use reciprocating paddles to press and release material in a sterile bag. Key components are a drive unit, a vessel or tube, the grinding element such as beads or pestle, and a cooling or cryogenic system to preserve labile biomolecules.
What are the key features?
- Cryogenic cooling to -20 to -80 °C preserves RNA and metabolites
- Processes 48–96 tubes or deep-well plates in a batch
- Oscillation of about 6–8 m/s for rapid disruption
- Automated liquid nitrogen feed with temperature sensor
- Safety shutoff for oxygen depletion and overpressure
- Suited to large studies with hundreds of samples
What are the technical specifications?
A typical high-throughput bead mill with cryogenic cooling configuration offers oscillation speed of 6–8 m/s, sample capacity of 48–96 tubes or plates, tube size of 1.4–2 mL, chamber temperature of -20 to -80 °C, cooling method of Liquid nitrogen vapor or cold gas and cycle time of 30–120 s. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The High-Throughput Bead Mill with Cryogenic Cooling is used in metabolomics sample preparation, RNA extraction in large studies, biobank processing, plant genomics and clinical research sample preparation. Across the wider Tissue Homogenizers class, laboratories also deploy it for DNA and RNA extraction from tissue, protein and enzyme extraction and plant and seed sample preparation.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-051, ISO 6887-1, ISO 7218 and GB 4789.1. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Keep tissue cold and process quickly to preserve RNA, proteins and enzyme activity; add stabilizing buffers where appropriate. Load tubes symmetrically in bead mills and do not exceed the rated tube fill volume, which is usually half of the tube. Select bead size and material to match tissue hardness, and avoid contamination with metals if trace element analysis follows. Follow the supplier's method for each tissue type, and validate homogenization efficiency against a reference method. For infectious or biohazardous material, use sealed tubes and work in a biosafety cabinet. Clean glass homogenizers thoroughly, and handle liquid nitrogen with protective equipment. Comply with IEC 61010-1 and local biosafety rules.
How do I select the right High-Throughput Bead Mill with Cryogenic Cooling?
Select the cryogenic high-throughput mill for large sample sets where RNA or metabolite integrity requires cold processing. A standard bead mill is enough for room-temperature work. In the RFQ, specify sample number, tube or plate type, temperature range and liquid nitrogen supply.
How does it compare with other Tissue Homogenizers variants?
Choose a tissue homogenizer by sample type, throughput, sample size and downstream analysis. Bead mills handle soft and tough tissues, microbes and plant material in sealed tubes, and are the usual choice for high throughput with 24 or more samples at once. Choose cryogenic cooling for RNA and labile metabolites. Potter-Elvehjem homogenizers give gentle, reproducible disruption of soft tissue such as liver and brain, preserving organelles. Cryogenic grinders pulverize very hard or brittle samples such as bone and seeds. Paddle blenders suit food and microbiology samples of 10 to 400 mL. Check tube volumes, bead types, speed control, cooling and aerosol containment. For regulated testing, consider cross-contamination prevention and documented cleaning steps. Confirm noise, vibration and safety interlocks.
Full specifications
| Oscillation speed | 6–8 m/s |
|---|---|
| Sample capacity | 48–96 tubes or plates |
| Tube size | 1.4–2 mL |
| Chamber temperature | -20 to -80 °C |
| Cooling method | Liquid nitrogen vapor or cold gas |
| Cycle time | 30–120 s |
| Temperature control | Sensor with automated feed |
| Safety | Oxygen and overpressure shutoff |
| Programs | Up to 30 stored |
| Noise level | 75–85 dB(A) |
| Power supply | 200–240 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Metabolomics sample preparation
- RNA extraction in large studies
- Biobank processing
- Plant genomics
- Clinical research sample preparation
Key features
- Cryogenic cooling to -20 to -80 °C preserves RNA and metabolites
- Processes 48–96 tubes or deep-well plates in a batch
- Oscillation of about 6–8 m/s for rapid disruption
- Automated liquid nitrogen feed with temperature sensor
- Safety shutoff for oxygen depletion and overpressure
- Suited to large studies with hundreds of samples
Frequently asked questions about High-Throughput Bead Mill with Cryogenic Cooling
Bead beating generates heat that degrades RNA, enzymes and some metabolites. Cold processing keeps samples frozen or chilled, preserving integrity for downstream analysis.
Look for oxygen depletion monitoring, pressure relief, insulated lines and automatic shutoff. Ensure the room is ventilated and users wear cryogenic protective equipment.
With 48 to 96 samples per batch and cycle times of a few minutes, hundreds of samples per hour are feasible. Actual throughput depends on loading and unloading time.
A tissue homogenizer breaks tissue into uniform suspensions or lysates by bead impact, grinding, pestle shear or paddle action. It prepares samples for DNA, RNA, protein and metabolite analysis in life science, clinical and food laboratories.
Bead mills with cooling and cryogenic grinders protect RNA by keeping samples cold and processing quickly. Use RNase-free tubes and lysis buffer that inactivates nucleases immediately.
A bead mill shakes sealed tubes with beads and handles many samples, while a rotor-stator probe is immersed in each sample. Bead mills avoid cross-contamination, whereas probes handle larger volumes.