

TGA-MS Coupled Thermogravimetric Analyzer
热重-质谱联用分析仪
- SKU TGA-0005
- TGA
- CE (to be confirmed)
- IEC 61010-1 safety (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Temperature range | Ambient–1000 °C (TGA) |
|---|---|
| Balance resolution | 0.1 µg |
| Interface temperature | Up to 250 °C |
| Mass range | 1–300 amu |
| Scan rate | Up to 10 spectra/s |
| Detection limit | ppm range for many species |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM E1131, ASTM E2550, ASTM D3850
What is the TGA-MS Coupled Thermogravimetric Analyzer?
A TGA-MS coupled analyzer samples evolved gases through a heated capillary into a mass spectrometer, giving mass-to-charge spectra that identify individual species by molecular mass. It detects gases that infrared cannot see and follows isotope-labelled or trace volatile release.
What is the TGA-MS Coupled Thermogravimetric Analyzer?
A TGA-MS coupled analyzer samples evolved gases through a heated capillary into a mass spectrometer, giving mass-to-charge spectra that identify individual species by molecular mass. It detects gases that infrared cannot see and follows isotope-labelled or trace volatile release.
Overview
A heated capillary or skimmer interface draws gas from the thermogravimetric exhaust into the ion source of a quadrupole mass spectrometer, where molecules are ionized and separated by mass-to-charge ratio. Inert carrier dilution is reduced by the vacuum interface, so sensitivity is high and detection limits reach parts per million for many species. The technique identifies hydrogen, water, carbon monoxide, carbon dioxide, ammonia, hydrogen chloride, sulfur dioxide and light organic fragments, and it follows selected ion currents continuously or steps through predefined masses in cycle mode. Because mass spectra can be ambiguous for isomers and overlapping fragments, correlation with infrared data or MS-MS helps. Typical instruments scan from 1 to 300 atomic mass units at up to ten spectra per second, which allows fast heating rates, and capillary interface temperature control prevents condensation of higher-boiling products.
How does it work?
A sensitive balance holds the sample in a furnace whose temperature follows a program, usually from ambient to 1000 or 1600 degrees Celsius, at rates of 1 to 50 degrees Celsius per minute. The balance beam is purged to protect it from heat and condensable vapours, and a separate purge gas flows over the sample to set the atmosphere: inert nitrogen or argon for decomposition studies, air or oxygen for oxidative tests, or a reactant gas for specific reactions. The instrument records mass against temperature or time, and the derivative curve is used to locate the onset of each mass loss step. Buoyancy and gas-flow effects are corrected with a blank run. Calibration uses certified mass standards and Curie-point or melting-point references for temperature. Typical balance resolution is 0.1 microgram with a sample of a few milligrams, giving a measurement precision of about 0.1 percent by mass.
What are the key features?
- Heated capillary interface at up to 250 °C into a quadrupole mass spectrometer
- Detection of nitrogen, hydrogen and other infrared-inactive gases
- Selected ion monitoring with up to 10 spectra per second
- Mass range covering 1 to 300 atomic mass units
- Isotope labelling support for mechanism studies
- Software correlating ion currents with mass loss curves
What are the technical specifications?
A typical tga-ms coupled thermogravimetric analyzer configuration offers temperature range of Ambient–1000 °C (TGA), balance resolution of 0.1 µg, interface temperature of Up to 250 °C, mass range of 1–300 amu, scan rate of Up to 10 spectra/s and detection limit of ppm range for many species. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The TGA-MS Coupled Thermogravimetric Analyzer is used in decomposition mechanism research, battery and electrolyte outgassing, catalyst and sorbent studies, ceramic binder burnout analysis and isotope-labelled polymer degradation. Across the wider TGA class, laboratories also deploy it for polymer composition and filler content, pharmaceutical hydrate and solvate studies and coal, biomass and fuel analysis.
Which standards and certifications apply?
Relevant standards and methods include ASTM E1131, ASTM E2550, ASTM D3850, ISO 11358-1, ISO 11358-2 and USP <891>. Certification candidates for this model are CE, IEC 61010-1 safety and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Choose crucibles that do not react with the sample or the gas: alumina for most work, platinum for oxidative tests or when high thermal conductivity helps, and quartz or ceramic for high-temperature inert runs. Keep sample mass between 5 and 20 milligrams so the gas flow is not restricted and heat transfer is even. Run a blank to correct buoyancy and purge effects before starting a series, and verify mass with a calibration weight periodically. Condensable decomposition products must be kept out of the balance chamber, usually by a trap or by a higher balance purge flow. Temperature calibration should be repeated after a furnace or sensor change, and every run should record crucible type, gas, flow rate, heating rate and sample mass so results can be reproduced. Compliance laboratories should keep the raw curves, not just the calculated numbers.
How do I select the right TGA-MS Coupled Thermogravimetric Analyzer?
Select the mass spectrometer coupling when light gases, isotopes or trace volatiles must be identified, or when infrared spectra overlap badly. For routine functional group identification the FTIR coupling is simpler and cheaper. In an RFQ, specify mass range, scan rate, interface temperature and whether both couplings are required.
How does it compare with other TGA variants?
Decide the maximum temperature you need, because it drives the furnace design: 1000 degrees Celsius covers most polymers and pharmaceuticals, 1500 to 1600 degrees Celsius is needed for ceramics, metal oxides and slags. Then define the atmosphere and whether evolved gases must be identified, which determines whether an FTIR or mass spectrometer coupling is required. Consider the balance resolution you need: routine filler and moisture determinations work with microgram resolution, while thin films or residues need sub-microgram sensitivity. Automatic sample changers pay back quickly in quality control laboratories that run many samples. Check baseline stability, buoyancy correction, purge gas control, crucible material and the maximum heating rate, and confirm that the instrument's calibration procedures match the method you must follow, such as ASTM E1131 or ISO 11358.
Full specifications
| Temperature range | Ambient–1000 °C (TGA) |
|---|---|
| Balance resolution | 0.1 µg |
| Interface temperature | Up to 250 °C |
| Mass range | 1–300 amu |
| Scan rate | Up to 10 spectra/s |
| Detection limit | ppm range for many species |
| Ion source | Electron ionisation, 70 eV |
| Heating rate | 0.1–50 °C/min |
| Gas modes | Scan, selected ion monitoring, cycle |
| Data output | Coupled mass and MS data files |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Decomposition mechanism research
- Battery and electrolyte outgassing
- Catalyst and sorbent studies
- Ceramic binder burnout analysis
- Isotope-labelled polymer degradation
Key features
- Heated capillary interface at up to 250 °C into a quadrupole mass spectrometer
- Detection of nitrogen, hydrogen and other infrared-inactive gases
- Selected ion monitoring with up to 10 spectra per second
- Mass range covering 1 to 300 atomic mass units
- Isotope labelling support for mechanism studies
- Software correlating ion currents with mass loss curves
Frequently asked questions about TGA-MS Coupled Thermogravimetric Analyzer
Yes, nitrogen with mass-to-charge 28 can be monitored directly, unlike in infrared where it is inactive. This is useful for nitrides and nitrogen-containing polymers, though mass 28 also receives a contribution from carbon monoxide, so isotope labelling or multiple ion monitoring is used to separate them.
The capillary transports gases from near the furnace to the ion source, so any cold spot condenses higher-boiling products and distorts the time correlation with the mass curve. Heating it to 200 to 250 degrees Celsius keeps the transport quantitative.
A range of 1 to 300 atomic mass units covers water, small inorganics and most light organic fragments at a high scan rate. Extending to higher masses slows the scan or reduces the number of channels monitored, which can compromise fast-event tracking.
It measures sample mass as a function of temperature or time in a controlled atmosphere. The mass loss steps indicate moisture and volatiles, polymer or additive decomposition, filler and ash content, while the residue shows the non-volatile fraction at the final temperature.
Decomposition products can condense on the balance mechanism and change its calibration, so a protective gas flow keeps hot sample gases out of the balance chamber. The purge rate must be stable, because changes in flow alter apparent mass through buoyancy and drag effects.
Use nitrogen or argon for pyrolysis and composition analysis, because inert gas gives defined decomposition steps. Use air or oxygen when oxidation stability or oxidative decomposition temperature is required, and note that the same material can show very different curves in the two atmospheres.
Related models






