Automated Sample Preparation System for Content Uniformity Testing
含量均匀度自动样品前处理系统
- CE (to be confirmed)
- +2
Welcome to Lab Manufacturers China — laboratory instruments direct from a Chinese manufacturer

制药混合粉末取样系统
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
| Sample volume | 1–50 g per point |
|---|---|
| Sampling points per blend | 5–20 |
| Sampler material | Stainless steel or PTFE |
| Apertures | 3–6 for thief sampling |
| Container compatibility | Bottles or sample bags |
| Containment | Glove box or isolator option |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <905>, USP <711>, USP <1092>
A powder sampling system takes representative aliquots from blends, bins and drums for blend uniformity testing and process control. It is chosen when low-dose actives make sampling error a major risk to blend uniformity results.
A powder sampling system takes representative aliquots from blends, bins and drums for blend uniformity testing and process control. It is chosen when low-dose actives make sampling error a major risk to blend uniformity results.
Blend uniformity testing depends entirely on whether the sample represents the whole blend. A powder sampling system uses a thief with multiple apertures, a spinning riffler, or a sample port designed to take a core from top to bottom so the aliquot includes material from several depths. Sampling from many positions in the blender, bin or drum reduces the chance that local segregation, static charge or particle size differences distort the result. The system also protects the operator from dust exposure, which matters for potent compounds, and reduces contamination. Sample containers, tools and the sampler must be compatible with the drug and easy to clean, and sampling points should be defined in a written procedure. After sampling, the blend must be handled so that the taken volume does not invalidate the batch.
Sample preparation applies mechanical and chemical steps to make a sample representative and measurable. Tablets are weighed, comminuted by crushing, milling or grinding, and then dissolved or extracted in a volumetric flask or a closed vessel with a defined solvent and time. Powders are sampled with a thief or a spinning riffler so the aliquot reflects the whole blend. Dilution is performed by hand with volumetric glassware or automatically with syringes and valves, and solutions are filtered through membranes to protect the analytical column or detector. Solid-phase extraction concentrates or cleans up analytes before chromatography. Accuracy, completeness of extraction and freedom from contamination determine whether the analytical result is valid.
A typical powder sampling system for pharmaceutical blending configuration offers sample volume of 1–50 g per point, sampling points per blend of 5–20, sampler material of Stainless steel or PTFE, apertures of 3–6 for thief sampling, container compatibility of Bottles or sample bags and containment of Glove box or isolator option. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
The Powder Sampling System for Pharmaceutical Blending is used in blend uniformity testing, bin and drum sampling, low-dose formulation testing and potent compound handling. Across the wider Sample Preparation class, laboratories also deploy it for content uniformity sample preparation, assay sample preparation and dissolution sample handling.
Relevant standards and methods include USP <905>, USP <711>, USP <1092>, ICH Q2(R2), IEC 61010-1 and ISO 17025. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place equipment on a level, vibration-free bench and keep the area clean, because dust from powders can contaminate open vessels. Verify balances and pipettes at defined intervals and use certified reference weights. Confirm that extraction time and technique are reproducible, since incomplete extraction gives low assay results. Check solvent compatibility of seals, tubing and filters, and change membranes and SPE cartridges according to the method. Avoid cross-contamination by using disposable labware or validated wash cycles, and record reagent lots, sample weights and preparation conditions. Follow local rules for solvent handling and waste disposal.
Choose a representative sampling system when blend uniformity is a release or process control test, especially for low-dose products. Confirm sampler design, number of apertures, sampling depth, containment level and cleaning method. Define sampling points in a written procedure and validate that sampling does not disturb the blend beyond acceptable limits.
Select sample preparation equipment from the analytical method and the dosage form. Content uniformity and assay of tablets need precise weighing, complete comminution and accurate dilution. Dissolution studies need large numbers of filtered aliquots taken at timed intervals. Powders and blends need representative sampling rather than grinding. Solid-phase extraction suits trace analysis and complex matrices. Compare the number of samples per run, dilution ratios achievable, weighing accuracy, solvent compatibility, filtration type and carryover control. Automated platforms that combine weighing, dilution and filtration reduce labour and improve data integrity, and their software should support method storage, audit trails and export to a laboratory information management system.
| Sample volume | 1–50 g per point |
|---|---|
| Sampling points per blend | 5–20 |
| Sampler material | Stainless steel or PTFE |
| Apertures | 3–6 for thief sampling |
| Container compatibility | Bottles or sample bags |
| Containment | Glove box or isolator option |
| Cleaning | Removable parts and validated wash |
| Power supply | Manual or 220 V, 50 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Because the analytical result can only be as representative as the sample. If the sample is taken from a single position or a thin surface layer, local segregation or static can make a uniform blend appear non-uniform, or hide a real problem.
Commonly five to twenty points across the blender or bin, chosen to cover different depths and regions, including near the walls and the discharge. The number and positions should be justified and fixed in a written sampling procedure.
Dust exposure to highly potent actives requires containment such as a sampling port with local extraction, a glove box or an isolator, plus personal protective equipment. Cleaning validation and operator safety both depend on controlling powder release.
Because an analytical method can only be as good as the sample presented to it. Incomplete extraction, inaccurate weighing, non-representative sampling or contamination all produce results that are wrong even when the instrument performs perfectly.
Individual units are weighed, comminuted, transferred quantitatively to a volumetric flask and extracted with a defined solvent and time. The solution is filtered and measured, and the result for each unit is compared with the monograph acceptance criteria.
For trace analysis, complex matrices or analytes that need concentration before chromatography. The cartridge retains the analyte while interfering substances pass through, then the analyte is eluted in a small volume of solvent, which increases sensitivity and protects the column.