Automated Sample Preparation System for Content Uniformity Testing
含量均匀度自动样品前处理系统
- CE (to be confirmed)
- +2
Welcome to Lab Manufacturers China — laboratory instruments direct from a Chinese manufacturer

药品分析自动稀释过滤系统
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
| Dilution ratio | up to 1:10000 |
|---|---|
| Dispensing accuracy | about ±1 percent |
| Precision | about 0.5 percent RSD |
| Sample capacity | up to 60 vials per run |
| Filter type | 0.22 or 0.45 µm membrane |
| Solvent compatibility | Aqueous and organic |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <905>, USP <711>, USP <1092>
An automated dilution and filtration system prepares precise dilutions and filters them for chromatography or spectroscopy. It is chosen for high-volume pharmaceutical laboratories that need reproducible, accurate dilutions with limited routine operator handling.
An automated dilution and filtration system prepares precise dilutions and filters them for chromatography or spectroscopy. It is chosen for high-volume pharmaceutical laboratories that need reproducible, accurate dilutions with limited routine operator handling.
Many pharmaceutical methods require one or more dilutions before analysis, and manual volumetric work is slow and prone to error. An automated dilution and filtration system draws a measured aliquot with a syringe or piston pump, dispenses it into a vial or flask, adds solvent to a defined volume or ratio, mixes, and pushes the solution through a filter membrane into an autosampler vial. Dilution ratios can reach 1 in 10000, and systems often combine several dilution steps and internal standard addition in one method. Precision depends on syringe or pump accuracy, valve integrity and the absence of leaks, while carryover is managed with wash cycles and disposable tips or tubing. Barcode reading of source and destination vials maintains sample identity, and software records method parameters and results.
Sample preparation applies mechanical and chemical steps to make a sample representative and measurable. Tablets are weighed, comminuted by crushing, milling or grinding, and then dissolved or extracted in a volumetric flask or a closed vessel with a defined solvent and time. Powders are sampled with a thief or a spinning riffler so the aliquot reflects the whole blend. Dilution is performed by hand with volumetric glassware or automatically with syringes and valves, and solutions are filtered through membranes to protect the analytical column or detector. Solid-phase extraction concentrates or cleans up analytes before chromatography. Accuracy, completeness of extraction and freedom from contamination determine whether the analytical result is valid.
A typical automated dilution and filtration system for pharmaceutical analysis configuration offers dilution ratio of up to 1:10000, dispensing accuracy of about ±1 percent, precision of about 0.5 percent RSD, sample capacity of up to 60 vials per run, filter type of 0.22 or 0.45 µm membrane and solvent compatibility of Aqueous and organic. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
The Automated Dilution and Filtration System for Pharmaceutical Analysis is used in HPLC and UV-Vis sample preparation, dissolution sample processing, trace impurity analysis and cleaning validation samples. Across the wider Sample Preparation class, laboratories also deploy it for content uniformity sample preparation, assay sample preparation and dissolution sample handling.
Relevant standards and methods include USP <905>, USP <711>, USP <1092>, ICH Q2(R2), IEC 61010-1 and ISO 17025. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place equipment on a level, vibration-free bench and keep the area clean, because dust from powders can contaminate open vessels. Verify balances and pipettes at defined intervals and use certified reference weights. Confirm that extraction time and technique are reproducible, since incomplete extraction gives low assay results. Check solvent compatibility of seals, tubing and filters, and change membranes and SPE cartridges according to the method. Avoid cross-contamination by using disposable labware or validated wash cycles, and record reagent lots, sample weights and preparation conditions. Follow local rules for solvent handling and waste disposal.
Choose an automated dilution system when many samples need accurate, repeatable dilutions and operator time is limited. Confirm achievable dilution ratios, dispensing accuracy and precision, filter compatibility with your solvents and carryover control. Check that the output vials fit your autosampler and that the software records method and sample identity.
Select sample preparation equipment from the analytical method and the dosage form. Content uniformity and assay of tablets need precise weighing, complete comminution and accurate dilution. Dissolution studies need large numbers of filtered aliquots taken at timed intervals. Powders and blends need representative sampling rather than grinding. Solid-phase extraction suits trace analysis and complex matrices. Compare the number of samples per run, dilution ratios achievable, weighing accuracy, solvent compatibility, filtration type and carryover control. Automated platforms that combine weighing, dilution and filtration reduce labour and improve data integrity, and their software should support method storage, audit trails and export to a laboratory information management system.
| Dilution ratio | up to 1:10000 |
|---|---|
| Dispensing accuracy | about ±1 percent |
| Precision | about 0.5 percent RSD |
| Sample capacity | up to 60 vials per run |
| Filter type | 0.22 or 0.45 µm membrane |
| Solvent compatibility | Aqueous and organic |
| Carryover control | Wash cycles and disposable tips |
| Power supply | 220 V, 50 Hz, about 0.3 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Typically within about one percent for dispensing and around 0.5 percent relative standard deviation for repeated dilutions, provided the syringes or pumps are calibrated and free of leaks. Multi-step dilutions accumulate error, so the fewest steps that meet the requirement are preferred.
On most platforms yes, by dispensing a fixed volume of internal standard solution into each vial before final dilution. The internal standard corrects for injection and dilution variability, which improves reproducibility for trace analysis.
With wash cycles between samples using a suitable solvent, disposable tips or tubing, and a defined number of wash steps validated for the analyte. High-concentration samples followed by low-concentration ones should be checked during validation.
Because an analytical method can only be as good as the sample presented to it. Incomplete extraction, inaccurate weighing, non-representative sampling or contamination all produce results that are wrong even when the instrument performs perfectly.
Individual units are weighed, comminuted, transferred quantitatively to a volumetric flask and extracted with a defined solvent and time. The solution is filtered and measured, and the result for each unit is compared with the monograph acceptance criteria.
For trace analysis, complex matrices or analytes that need concentration before chromatography. The cartridge retains the analyte while interfering substances pass through, then the analyte is eluted in a small volume of solvent, which increases sensitivity and protects the column.