Automated Sample Preparation System for Content Uniformity Testing
含量均匀度自动样品前处理系统
- CE (to be confirmed)
- +2
Welcome to Lab Manufacturers China — laboratory instruments direct from a Chinese manufacturer

制药样品固相萃取系统
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
| Format | 1, 3 or 6 mL cartridges or 96-well plate |
|---|---|
| Sorbent mass | 30–500 mg |
| Particle size | about 40–60 µm |
| Chemistry options | C18, C8, mixed-mode, ion exchange |
| Sample volume | 0.1–100 mL |
| Elution volume | 0.5–5 mL |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <905>, USP <711>, USP <1092>
A solid-phase extraction system cleans up and concentrates pharmaceutical analytes before chromatography using disposable cartridges or plates. It is chosen for trace impurities, biological matrices and methods with a low limit of quantitation.
A solid-phase extraction system cleans up and concentrates pharmaceutical analytes before chromatography using disposable cartridges or plates. It is chosen for trace impurities, biological matrices and methods with a low limit of quantitation.
Solid-phase extraction passes a sample through a sorbent that retains the analyte, washes away interfering substances and then elutes the analyte in a small volume of solvent. The result is a cleaner and often more concentrated extract, which improves chromatographic separation and lowers the limit of quantitation. Pharmaceutical uses include trace impurity and genotoxic impurity analysis, residual solvent and cleaning validation samples, and biological matrices in bioanalysis. Selection depends on the analyte chemistry and matrix: reversed-phase sorbents for non-polar analytes, ion exchange for charged species, and mixed-mode for complex samples. Automated systems control conditioning, loading, washing and elution volumes, which improves reproducibility, and plates with 96 wells allow parallel processing. Carryover, sorbent lot variation and solvent compatibility must be controlled.
Sample preparation applies mechanical and chemical steps to make a sample representative and measurable. Tablets are weighed, comminuted by crushing, milling or grinding, and then dissolved or extracted in a volumetric flask or a closed vessel with a defined solvent and time. Powders are sampled with a thief or a spinning riffler so the aliquot reflects the whole blend. Dilution is performed by hand with volumetric glassware or automatically with syringes and valves, and solutions are filtered through membranes to protect the analytical column or detector. Solid-phase extraction concentrates or cleans up analytes before chromatography. Accuracy, completeness of extraction and freedom from contamination determine whether the analytical result is valid.
A typical solid-phase extraction system for pharmaceutical samples configuration offers format of 1, 3 or 6 mL cartridges or 96-well plate, sorbent mass of 30–500 mg, particle size of about 40–60 µm, chemistry options of C18, C8, mixed-mode, ion exchange, sample volume of 0.1–100 mL and elution volume of 0.5–5 mL. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
The Solid-Phase Extraction System for Pharmaceutical Samples is used in trace impurity analysis, genotoxic impurity testing, cleaning validation samples and bioanalytical sample clean-up. Across the wider Sample Preparation class, laboratories also deploy it for content uniformity sample preparation, assay sample preparation and dissolution sample handling.
Relevant standards and methods include USP <905>, USP <711>, USP <1092>, ICH Q2(R2), IEC 61010-1 and ISO 17025. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place equipment on a level, vibration-free bench and keep the area clean, because dust from powders can contaminate open vessels. Verify balances and pipettes at defined intervals and use certified reference weights. Confirm that extraction time and technique are reproducible, since incomplete extraction gives low assay results. Check solvent compatibility of seals, tubing and filters, and change membranes and SPE cartridges according to the method. Avoid cross-contamination by using disposable labware or validated wash cycles, and record reagent lots, sample weights and preparation conditions. Follow local rules for solvent handling and waste disposal.
Choose solid-phase extraction when the method needs a cleaner or more concentrated extract than filtration alone can give. Select the sorbent chemistry from the analyte and matrix, then confirm cartridge size, sorbent mass and elution volume. Validate recovery and carryover, and control sorbent lot variation for regulated work.
Select sample preparation equipment from the analytical method and the dosage form. Content uniformity and assay of tablets need precise weighing, complete comminution and accurate dilution. Dissolution studies need large numbers of filtered aliquots taken at timed intervals. Powders and blends need representative sampling rather than grinding. Solid-phase extraction suits trace analysis and complex matrices. Compare the number of samples per run, dilution ratios achievable, weighing accuracy, solvent compatibility, filtration type and carryover control. Automated platforms that combine weighing, dilution and filtration reduce labour and improve data integrity, and their software should support method storage, audit trails and export to a laboratory information management system.
| Format | 1, 3 or 6 mL cartridges or 96-well plate |
|---|---|
| Sorbent mass | 30–500 mg |
| Particle size | about 40–60 µm |
| Chemistry options | C18, C8, mixed-mode, ion exchange |
| Sample volume | 0.1–100 mL |
| Elution volume | 0.5–5 mL |
| Manifold positions | 12–96 |
| Power supply | 220 V, 50 Hz, about 0.2 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
When analytes are present at low concentrations in a complex matrix, when interfering substances must be removed before chromatography, or when the sample needs concentration. Simple filtration suffices for many clean, high-concentration samples.
From the analyte and matrix. Reversed-phase sorbents retain non-polar analytes, ion-exchange sorbents retain charged species, and mixed-mode sorbents combine both for complex samples. The wash and elution solvents must be chosen so the analyte is retained and then released cleanly.
Sorbent manufacturing can vary in particle size, surface chemistry and end-capping, which changes retention slightly. For regulated methods, lot-to-lot verification or a single qualified lot should be used, and recovery should be rechecked when the lot changes.
Because an analytical method can only be as good as the sample presented to it. Incomplete extraction, inaccurate weighing, non-representative sampling or contamination all produce results that are wrong even when the instrument performs perfectly.
Individual units are weighed, comminuted, transferred quantitatively to a volumetric flask and extracted with a defined solvent and time. The solution is filtered and measured, and the result for each unit is compared with the monograph acceptance criteria.
For trace analysis, complex matrices or analytes that need concentration before chromatography. The cartridge retains the analyte while interfering substances pass through, then the analyte is eluted in a small volume of solvent, which increases sensitivity and protects the column.

含量均匀度自动样品前处理系统

药品分析自动稀释过滤系统