Tablet Thickness and Diameter Tester
片剂厚度与直径测试仪
- SKU TAA-0004
- Tablet Analysis
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Thickness range | 0–15 mm |
|---|---|
| Diameter range | 0–30 mm |
| Resolution | 0.01 mm |
| Accuracy | about ±0.02 mm |
| Measurement type | Contact gauge or optical |
| Hardness option | 0–500 N combined |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <1216>, USP <1217>, USP <701>
What is the Tablet Thickness and Diameter Tester?
A tablet thickness and diameter tester measures the dimensional properties of tablets with a contact gauge or optical sensor. It is chosen for process control because dimensions relate to die fill, compression force and weight uniformity.
What is the Tablet Thickness and Diameter Tester?
A tablet thickness and diameter tester measures the dimensional properties of tablets with a contact gauge or optical sensor. It is chosen for process control because dimensions relate to die fill, compression force and weight uniformity.
Overview
Thickness and diameter are simple measurements but they carry a lot of information. Thickness reflects the compression force and the amount of material in the die, so an increase in thickness at constant weight indicates lower density or over-lubrication, while a decrease suggests harder compression. Diameter is fixed by the tooling and confirms that the correct punch set is in use and that the die and punches are not worn. Instruments use a micrometer-style contact gauge or a non-contact optical or laser sensor, with resolution typically 0.01 mm, and may measure hardness at the same position so the tablet is characterised in one handling step. Statistical reporting of mean, range and standard deviation, or of coefficient of variation, supports process control and batch release.
How does it work?
Tablet analysis applies mechanical and physical tests to individual dosage units. A hardness tester presses a tablet between two platens and records the force at which it breaks, expressed in newtons or kiloponds. A friability tester rotates tablets in a drum so they tumble and abrade, and the mass loss after a set number of revolutions indicates mechanical durability, normally less than one percent. A disintegration tester moves tablets up and down in a basket immersed in medium at 37 °C and records when no residue remains. A gauge measures thickness and diameter, and automated systems combine several tests so a batch is characterised unit by unit, which also supports statistical process control. Temperature, humidity, test speed and instrument calibration influence results.
What are the key features?
- Contact micrometer or non-contact optical sensor
- Resolution of about 0.01 mm
- Thickness and diameter in one measurement
- Optional simultaneous hardness measurement
- Statistical reporting of mean and variation
- Manual or automatic tablet feeding
What are the technical specifications?
A typical tablet thickness and diameter tester configuration offers thickness range of 0–15 mm, diameter range of 0–30 mm, resolution of 0.01 mm, accuracy of about ±0.02 mm, measurement type of Contact gauge or optical and hardness option of 0–500 N combined. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Tablet Thickness and Diameter Tester is used in in-process thickness control, tooling and punch wear checks, weight uniformity support and automated tablet testing systems. Across the wider Tablet Analysis class, laboratories also deploy it for tablet hardness release testing, friability testing of tablets and disintegration testing of tablets and capsules.
Which standards and certifications apply?
Relevant standards and methods include USP <1216>, USP <1217>, USP <701>, Ph. Eur. 2.9.1, ICH Q2(R2) and IEC 61010-1. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Keep the instruments in a room with controlled temperature and humidity, because tablets absorb or lose moisture and that changes hardness and friability. Condition samples before testing and record the conditioning time. Calibrate hardness load cells and verify disintegration temperatures at defined intervals, and check friability drums for wear. Clean residues from platens, baskets and drums, and inspect for corrosion from prolonged contact with water. Test adequate numbers of units, since tablet properties vary within a batch, and keep records of results, conditions and equipment status. For automated systems, back up data and review audit trails regularly.
How do I select the right Tablet Thickness and Diameter Tester?
Choose a dimensional tester when thickness and diameter are part of your specification or process control. Confirm range, resolution and accuracy for your tablet sizes, and whether hardness can be measured in the same handling. Verify calibration with gauge blocks or certified standards at defined intervals.
How does it compare with other Tablet Analysis variants?
Choose instruments according to the tests in the pharmacopoeial monograph and the dosage form. Hardness, friability and disintegration testers are the core trio for conventional tablets, while thickness and diameter measurement supports weight and appearance control. Automated multi-parameter systems suit high-volume release testing and process optimisation, because they test many units and export statistics without manual records. Compare measurement ranges, accuracy and resolution, throughput, number of test positions or stations, and software for data handling and audit trails. For disintegration, check basket mesh size, stroke and temperature control; for friability, check drum dimensions, rotation speed and counting. Confirm calibration standards and qualification documents.
Full specifications
| Thickness range | 0–15 mm |
|---|---|
| Diameter range | 0–30 mm |
| Resolution | 0.01 mm |
| Accuracy | about ±0.02 mm |
| Measurement type | Contact gauge or optical |
| Hardness option | 0–500 N combined |
| Reported statistics | Mean, range, coefficient of variation |
| Power supply | 220 V, 50 Hz, about 0.1 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- In-process thickness control
- Tooling and punch wear checks
- Weight uniformity support
- Automated tablet testing systems
Key features
- Contact micrometer or non-contact optical sensor
- Resolution of about 0.01 mm
- Thickness and diameter in one measurement
- Optional simultaneous hardness measurement
- Statistical reporting of mean and variation
- Manual or automatic tablet feeding
Frequently asked questions about Tablet Thickness and Diameter Tester
Thickness depends on the amount of material in the die and the compression force. A change in bulk density, flow or die fill, or a change in compression force, alters thickness even when the tablet weight is unchanged, so thickness is a useful process indicator.
Contact gauges are simple and accurate for flat tablets but can mark soft or coated surfaces. Optical sensors avoid contact and are faster for automated systems, but need careful calibration and can be affected by surface colour or dust.
Verification with gauge blocks or certified standards should be performed at defined intervals, commonly before each batch or daily for critical work, and after any service or relocation. Results should be recorded against the acceptance limits.
Common physical tests are hardness or crushing strength, friability, disintegration time, thickness and diameter, and weight uniformity. Together with content uniformity and dissolution, they show that a batch will handle, package and release as intended.
For most compressed tablets the accepted limit is a mass loss of not more than one percent after 100 revolutions at 25 rpm, with no tablet cracked, broken or fragmented. The pharmacopoeial chapter defines the exact conditions and acceptance criteria.
Disintegration medium is held at 37 ±2 °C because higher temperatures speed disintegration and lower temperatures slow it, and results are compared against monograph limits measured under defined conditions. Temperature control and verification are therefore part of method validation.