Automated Liquid Handling Workstation
自动化移液工作站
- SKU SAP-0005
- Sample Processing
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-2-081 test report (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Number of channels | 1, 4, 8, 12 or 96 |
|---|---|
| Volume range | 0.5–1,000 μL (tip dependent) |
| Pipetting accuracy | ±2 % at 10 μL |
| Pipetting precision (CV) | below 2 % at 10 μL |
| Deck positions | 12–20 |
| Plate formats | 96, 384-well, deep-well |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-020, IEC 61326-1
What is the Automated Liquid Handling Workstation?
An automated liquid handling workstation dispenses, dilutes and transfers samples and reagents between tubes and microplates using programmable pipetting channels. It fits laboratories that must prepare PCR, library or assay plates reproducibly at medium to high throughput with minimal manual intervention.
What is the Automated Liquid Handling Workstation?
An automated liquid handling workstation dispenses, dilutes and transfers samples and reagents between tubes and microplates using programmable pipetting channels. It fits laboratories that must prepare PCR, library or assay plates reproducibly at medium to high throughput with minimal manual intervention.
Overview
An automated liquid handling workstation consists of a deck with positions for tips, tube racks, reagent troughs and microplates, a pipetting arm with one to 96 channels, and a control computer running scripting software. Channels use air-displacement pipetting, sometimes with liquid-level detection by capacitance or pressure, and can dispense from 0.5 μL to 1,000 μL depending on the tip. Gripper arms can move plates to heaters, shakers or magnetic separation modules. HEPA filtration and UV decontamination are options for clean workflows. Good systems provide protocol templates for nucleic acid extraction, PCR setup and normalization, plus audit logging. Accuracy depends on liquid class parameters, which should be tuned for viscous or volatile liquids.
How does it work?
Sample processing instruments apply controlled energy to break down biological structures and then separate the components of interest. Bead mills shake tubes containing ceramic, glass or steel beads at several meters per second so that impact and shear rupture cells and tissue. Ultrasonic disruptors drive a titanium probe at about 20 kHz, and cavitation bubble collapse lyses cells. High-pressure disruptors force suspensions through a narrow valve at 500 to 2,000 bar, generating shear and pressure drop. Centrifuges separate particles by sedimentation in a centrifugal field expressed as relative centrifugal force (RCF), with refrigeration to protect labile molecules. Automated liquid handlers use air-displacement or positive-displacement pipetting channels and deck-mounted labware to transfer, dilute and plate samples reproducibly.
What are the key features?
- Programmable 1 to 8 channel or 96-channel pipetting heads for flexible throughput.
- Liquid-level detection and clot detection reduce failed transfers.
- Deck supports tubes, deep-well plates, 96 and 384-well microplates.
- Optional magnetic, heating and shaking modules for on-deck extraction.
- HEPA filtration or UV decontamination options for clean workflows.
- Protocol scripting software with audit log and user access levels.
What are the technical specifications?
A typical automated liquid handling workstation configuration offers number of channels of 1, 4, 8, 12 or 96, volume range of 0.5–1,000 μL (tip dependent), pipetting accuracy of ±2 % at 10 μL, pipetting precision (CV) of below 2 % at 10 μL, deck positions of 12–20 and plate formats of 96, 384-well, deep-well. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automated Liquid Handling Workstation is used in PCR and qPCR plate setup, nucleic acid extraction automation, NGS library preparation and ELISA and cell assay plate preparation. Across the wider Sample Processing class, laboratories also deploy it for tissue homogenization for RNA extraction, bacterial and yeast cell lysis and protein extraction for Western blot.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-020, IEC 61326-1, ISO 8655 and IEC 61010-2-010. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-2-081 test report; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place heavy instruments such as centrifuges on a level, vibration-free bench and allow ventilation clearance. Check rotors and buckets for wear, and log run hours against manufacturer limits. Probe sonicators and bead mills need sound enclosures and hearing protection. Calibrate pipetting channels periodically, typically with gravimetric or photometric checks per ISO 8655, and verify centrifuge speed with a tachometer. Clean between samples to avoid carry-over, using nuclease-free consumables for RNA work. Aerosol-generating steps involving infectious material should be performed in a biosafety cabinet or sealed rotors, following local biosafety rules.
How do I select the right Automated Liquid Handling Workstation?
Choose a liquid handler when manual pipetting is the error source or limits throughput. Specify channel count, volume range, plate formats, liquid-level detection, on-deck modules, filtration and software needs such as audit trail. Validate accuracy on your liquids with gravimetric checks before adopting a protocol.
How does it compare with other Sample Processing variants?
Select by sample type first. Tough or fibrous tissue, plant material and spores need bead beating or rotor-stator shear, while soft tissue and cultured cells can be lysed by sonication or detergent-assisted methods. Consider batch size: bead mills handle 24 to 48 tubes at once, whereas probe sonicators process one sample at a time. Match the instrument to the downstream target, since heat and shear damage RNA and intact proteins, making cooling and pulse control important. For separation, choose rotor capacity and maximum RCF for your tube formats, and confirm refrigeration down to 4 °C or lower. For automation, define the number of deck positions, tip formats and volume range, and confirm that scripting software supports your protocol.
Full specifications
| Number of channels | 1, 4, 8, 12 or 96 |
|---|---|
| Volume range | 0.5–1,000 μL (tip dependent) |
| Pipetting accuracy | ±2 % at 10 μL |
| Pipetting precision (CV) | below 2 % at 10 μL |
| Deck positions | 12–20 |
| Plate formats | 96, 384-well, deep-well |
| Liquid-level detection | Capacitive or pressure-based |
| Positioning repeatability | ±0.1 mm |
| Clean air option | HEPA filter, UV lamp |
| Power supply | 100–240 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- PCR and qPCR plate setup
- Nucleic acid extraction automation
- NGS library preparation
- ELISA and cell assay plate preparation
Key features
- Programmable 1 to 8 channel or 96-channel pipetting heads for flexible throughput.
- Liquid-level detection and clot detection reduce failed transfers.
- Deck supports tubes, deep-well plates, 96 and 384-well microplates.
- Optional magnetic, heating and shaking modules for on-deck extraction.
- HEPA filtration or UV decontamination options for clean workflows.
- Protocol scripting software with audit log and user access levels.
Frequently asked questions about Automated Liquid Handling Workstation
Verify accuracy and precision at several volumes using gravimetric or photometric methods following ISO 8655 principles, test with your actual reagents and liquid classes, and confirm carry-over with alternating dye and blank wells. Repeat periodically and after maintenance.
Yes, with tuned liquid classes using slower aspiration and dispense speeds, pauses and sometimes positive-displacement tips. Validate each liquid by weighing, because default water settings typically under-deliver viscous liquids and over-deliver volatile solvents.
An 8-channel arm offers flexibility for tubes, reagent distribution and variable layouts. A 96-channel head transfers a full plate in one motion and suits high-throughput plate-to-plate work, but is less flexible for individual tubes. Choose based on the share of plate-based work.
It is the group of instruments that disrupt, homogenize, separate and dispense biological samples before analysis. Examples include bead mills, sonicators, high-pressure disruptors, refrigerated centrifuges and automated liquid handlers that prepare lysates, extracts and assay plates for PCR, proteomics and cell-based work.
Keep samples cold, use short pulses or chilled bead-mill blocks, add a denaturing lysis buffer immediately, and use nuclease-free tubes and beads. Limit processing time, because heat and prolonged shear increase RNase activity and fragmentation. Verify integrity afterwards using an RNA integrity number or electrophoresis.
RPM is rotor rotational speed, whereas RCF expresses the actual force on the sample and depends on rotor radius. RCF equals 1.118 × 10⁻⁵ × radius in cm × RPM². Protocols should specify RCF so results remain reproducible across different centrifuge and rotor models.