High-Pressure Cell Disruptor

高压细胞破碎仪

  • SKU SAP-0003
  • Sample Processing
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • PED pressure equipment assessment (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Maximum pressure1,500–2,000 bar
Flow rate1–6 L/h (benchtop)
Minimum sample volume50–100 mL
Sample viscosityup to 500 mPa·s
Temperature controlCooling jacket to 4–10 °C
Wetted materials316L stainless steel, ceramic
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-020, IEC 61326-1

What is the High-Pressure Cell Disruptor?

A high-pressure cell disruptor forces a cell suspension through a narrow valve at 500 to 2,000 bar to rupture microbial and mammalian cells. It is the preferred choice for lysing large volumes in protein purification and scale-up studies where reproducible, continuous processing matters.

What is the High-Pressure Cell Disruptor?

A high-pressure cell disruptor forces a cell suspension through a narrow valve at 500 to 2,000 bar to rupture microbial and mammalian cells. It is the preferred choice for lysing large volumes in protein purification and scale-up studies where reproducible, continuous processing matters.

Overview

A high-pressure cell disruptor uses a positive-displacement pump to drive the suspension to set pressure, then releases it through an adjustable valve or fixed-geometry orifice. The sudden pressure drop, shear, impact and turbulence rupture cells. Pressure is set by the operator and monitored by a transducer, so conditions are reproducible from run to run. Benchtop models process 50 mL to several liters, with typical flow of 1 to 6 L/h, while pilot models run higher. A cooling jacket or pre-chilled heat exchanger removes the heat generated. One to three passes are commonly needed for E. coli and yeast, with yeast often needing higher pressure. Wetted parts in stainless steel and ceramic resist abrasion, and cleaning-in-place procedures support use between different products.

How does it work?

Sample processing instruments apply controlled energy to break down biological structures and then separate the components of interest. Bead mills shake tubes containing ceramic, glass or steel beads at several meters per second so that impact and shear rupture cells and tissue. Ultrasonic disruptors drive a titanium probe at about 20 kHz, and cavitation bubble collapse lyses cells. High-pressure disruptors force suspensions through a narrow valve at 500 to 2,000 bar, generating shear and pressure drop. Centrifuges separate particles by sedimentation in a centrifugal field expressed as relative centrifugal force (RCF), with refrigeration to protect labile molecules. Automated liquid handlers use air-displacement or positive-displacement pipetting channels and deck-mounted labware to transfer, dilute and plate samples reproducibly.

What are the key features?

  • Operating pressure up to 2,000 bar for bacteria and yeast lysis.
  • Reproducible, continuous flow processing of 50 mL to several liters.
  • Integrated cooling of the product path to limit heat rise.
  • Stainless steel and ceramic wetted parts resist abrasion and corrosion.
  • Adjustable valve or fixed orifice options for different cell types.
  • Pressure display with overpressure safety relief.

What are the technical specifications?

A typical high-pressure cell disruptor configuration offers maximum pressure of 1,500–2,000 bar, flow rate of 1–6 L/h (benchtop), minimum sample volume of 50–100 mL, sample viscosity of up to 500 mPa·s, temperature control of Cooling jacket to 4–10 °C and wetted materials of 316L stainless steel, ceramic. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The High-Pressure Cell Disruptor is used in E. coli and yeast lysis for protein purification, recombinant protein inclusion body recovery, mammalian and insect cell disruption and pilot-scale process development. Across the wider Sample Processing class, laboratories also deploy it for tissue homogenization for RNA extraction, bacterial and yeast cell lysis and protein extraction for Western blot.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-020, IEC 61326-1, ISO 8655 and IEC 61010-2-010. Certification candidates for this model are CE, ISO 9001 manufacturing and PED pressure equipment assessment; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Place heavy instruments such as centrifuges on a level, vibration-free bench and allow ventilation clearance. Check rotors and buckets for wear, and log run hours against manufacturer limits. Probe sonicators and bead mills need sound enclosures and hearing protection. Calibrate pipetting channels periodically, typically with gravimetric or photometric checks per ISO 8655, and verify centrifuge speed with a tachometer. Clean between samples to avoid carry-over, using nuclease-free consumables for RNA work. Aerosol-generating steps involving infectious material should be performed in a biosafety cabinet or sealed rotors, following local biosafety rules.

How do I select the right High-Pressure Cell Disruptor?

Choose a high-pressure disruptor when lysing liters of microbial suspension with reproducible conditions, or when scaling a purification process. Specify maximum pressure, flow rate, minimum sample volume, viscosity, need for cooling and cleaning requirements. For under 50 mL or many small samples, a bead mill or sonicator is more practical.

How does it compare with other Sample Processing variants?

Select by sample type first. Tough or fibrous tissue, plant material and spores need bead beating or rotor-stator shear, while soft tissue and cultured cells can be lysed by sonication or detergent-assisted methods. Consider batch size: bead mills handle 24 to 48 tubes at once, whereas probe sonicators process one sample at a time. Match the instrument to the downstream target, since heat and shear damage RNA and intact proteins, making cooling and pulse control important. For separation, choose rotor capacity and maximum RCF for your tube formats, and confirm refrigeration down to 4 °C or lower. For automation, define the number of deck positions, tip formats and volume range, and confirm that scripting software supports your protocol.

Full specifications

Full specifications
Maximum pressure1,500–2,000 bar
Flow rate1–6 L/h (benchtop)
Minimum sample volume50–100 mL
Sample viscosityup to 500 mPa·s
Temperature controlCooling jacket to 4–10 °C
Wetted materials316L stainless steel, ceramic
Pressure readoutDigital, accuracy ±2 %
Motor power2.2–5.5 kW
Noise levelbelow 80 dB(A)
Power supply380 V, 50 Hz three-phase or 220 V single-phase

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • E. coli and yeast lysis for protein purification
  • Recombinant protein inclusion body recovery
  • Mammalian and insect cell disruption
  • Pilot-scale process development

Key features

  • Operating pressure up to 2,000 bar for bacteria and yeast lysis.
  • Reproducible, continuous flow processing of 50 mL to several liters.
  • Integrated cooling of the product path to limit heat rise.
  • Stainless steel and ceramic wetted parts resist abrasion and corrosion.
  • Adjustable valve or fixed orifice options for different cell types.
  • Pressure display with overpressure safety relief.

Frequently asked questions about High-Pressure Cell Disruptor

Typically one to three passes at 1,000 to 1,500 bar achieve over 90 percent lysis for E. coli, while yeast often needs higher pressure or extra passes. Efficiency should be confirmed by protein release assay or microscopy for each strain and growth condition.

Request a quotation for the High-Pressure Cell Disruptor