Ultrasonic Cell Disruptor
超声细胞破碎仪
- SKU SAP-0002
- Sample Processing
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 test report (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Output power | 150–1,200 W (model dependent) |
|---|---|
| Frequency | 20 kHz ±0.5 kHz |
| Amplitude adjustment | 10–100 % |
| Processing volume | 0.2–500 mL (probe dependent) |
| Probe diameter | 2–25 mm |
| Pulse timing | 0.1–99 s on/off |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-020, IEC 61326-1
What is the Ultrasonic Cell Disruptor?
An ultrasonic cell disruptor uses a high-frequency titanium probe to lyse cells by cavitation, and it can also shear DNA or emulsify samples. It suits small to medium volumes, from 0.2 mL up to about 500 mL, when tunable power and pulsed operation are needed.
What is the Ultrasonic Cell Disruptor?
An ultrasonic cell disruptor uses a high-frequency titanium probe to lyse cells by cavitation, and it can also shear DNA or emulsify samples. It suits small to medium volumes, from 0.2 mL up to about 500 mL, when tunable power and pulsed operation are needed.
Overview
An ultrasonic cell disruptor consists of a generator, a piezoelectric transducer and a replaceable titanium probe or horn. The generator supplies electrical energy at about 20 kHz, the transducer converts it into mechanical vibration, and the probe tip transmits amplitude into the sample. Cavitation bubbles form and collapse, producing local shear that ruptures cells. Amplitude is adjustable, commonly from 10 to 100 percent, and pulsed mode with on and off intervals limits heating. Probes from 2 to 25 mm diameter cover microtube to beaker volumes. Sound-proof enclosures and temperature probes are frequently added. Because the probe contacts the sample, cleaning between samples is required, and immersion in an ice bath is standard practice to protect proteins and nucleic acids.
How does it work?
Sample processing instruments apply controlled energy to break down biological structures and then separate the components of interest. Bead mills shake tubes containing ceramic, glass or steel beads at several meters per second so that impact and shear rupture cells and tissue. Ultrasonic disruptors drive a titanium probe at about 20 kHz, and cavitation bubble collapse lyses cells. High-pressure disruptors force suspensions through a narrow valve at 500 to 2,000 bar, generating shear and pressure drop. Centrifuges separate particles by sedimentation in a centrifugal field expressed as relative centrifugal force (RCF), with refrigeration to protect labile molecules. Automated liquid handlers use air-displacement or positive-displacement pipetting channels and deck-mounted labware to transfer, dilute and plate samples reproducibly.
What are the key features?
- Adjustable amplitude of roughly 10 to 100 percent for controlled energy input.
- Pulse on/off programming limits sample heating.
- Interchangeable probes from 2 mm to 25 mm for varied volumes.
- Optional sound-proof enclosure and temperature cutoff.
- Suitable for lysis, DNA shearing, emulsification and dispersion.
- Overload protection with automatic frequency tuning.
What are the technical specifications?
A typical ultrasonic cell disruptor configuration offers output power of 150–1,200 W (model dependent), frequency of 20 kHz ±0.5 kHz, amplitude adjustment of 10–100 %, processing volume of 0.2–500 mL (probe dependent), probe diameter of 2–25 mm and pulse timing of 0.1–99 s on/off. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Ultrasonic Cell Disruptor is used in bacterial and yeast cell lysis, chromatin and DNA shearing, liposome and nanoparticle dispersion and small-volume protein extraction. Across the wider Sample Processing class, laboratories also deploy it for tissue homogenization for RNA extraction, bacterial and yeast cell lysis and protein extraction for Western blot.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-020, IEC 61326-1, ISO 8655 and IEC 61010-2-010. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 test report; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place heavy instruments such as centrifuges on a level, vibration-free bench and allow ventilation clearance. Check rotors and buckets for wear, and log run hours against manufacturer limits. Probe sonicators and bead mills need sound enclosures and hearing protection. Calibrate pipetting channels periodically, typically with gravimetric or photometric checks per ISO 8655, and verify centrifuge speed with a tachometer. Clean between samples to avoid carry-over, using nuclease-free consumables for RNA work. Aerosol-generating steps involving infectious material should be performed in a biosafety cabinet or sealed rotors, following local biosafety rules.
How do I select the right Ultrasonic Cell Disruptor?
Choose an ultrasonic disruptor for small to medium volumes, chromatin or DNA shearing, or dispersion tasks that a bead mill cannot do. Specify probe diameter for your volume, power rating, need for an enclosure and a temperature sensor. For many tough tissue samples or high sample counts, a bead mill is usually more practical.
How does it compare with other Sample Processing variants?
Select by sample type first. Tough or fibrous tissue, plant material and spores need bead beating or rotor-stator shear, while soft tissue and cultured cells can be lysed by sonication or detergent-assisted methods. Consider batch size: bead mills handle 24 to 48 tubes at once, whereas probe sonicators process one sample at a time. Match the instrument to the downstream target, since heat and shear damage RNA and intact proteins, making cooling and pulse control important. For separation, choose rotor capacity and maximum RCF for your tube formats, and confirm refrigeration down to 4 °C or lower. For automation, define the number of deck positions, tip formats and volume range, and confirm that scripting software supports your protocol.
Full specifications
| Output power | 150–1,200 W (model dependent) |
|---|---|
| Frequency | 20 kHz ±0.5 kHz |
| Amplitude adjustment | 10–100 % |
| Processing volume | 0.2–500 mL (probe dependent) |
| Probe diameter | 2–25 mm |
| Pulse timing | 0.1–99 s on/off |
| Timer range | 1 s–99 h |
| Temperature cutoff | 0–100 °C, programmable |
| Probe material | Titanium alloy Ti-6Al-4V |
| Power supply | 220 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Bacterial and yeast cell lysis
- Chromatin and DNA shearing
- Liposome and nanoparticle dispersion
- Small-volume protein extraction
Key features
- Adjustable amplitude of roughly 10 to 100 percent for controlled energy input.
- Pulse on/off programming limits sample heating.
- Interchangeable probes from 2 mm to 25 mm for varied volumes.
- Optional sound-proof enclosure and temperature cutoff.
- Suitable for lysis, DNA shearing, emulsification and dispersion.
- Overload protection with automatic frequency tuning.
Frequently asked questions about Ultrasonic Cell Disruptor
Keep the sample in an ice-water bath, use pulsed mode such as 3 seconds on and 6 seconds off, limit total energy, and use a temperature cutoff if available. Overheating denatures proteins and degrades RNA, so cooling between pulse groups is a standard practice.
Micro-tips of 2 to 3 mm suit 0.2 to 5 mL, 6 to 13 mm probes suit 5 to 100 mL, and 19 to 25 mm horns suit larger volumes up to about 500 mL. The probe must be immersed without touching the vessel wall.
Yes, probe sonicators can fragment DNA to a few hundred base pairs, but size distribution is broader and less reproducible than with focused-ultrasonicator systems. Optimization of amplitude and cycles is needed, and fragment size should be confirmed by electrophoresis or a fragment analyzer.
It is the group of instruments that disrupt, homogenize, separate and dispense biological samples before analysis. Examples include bead mills, sonicators, high-pressure disruptors, refrigerated centrifuges and automated liquid handlers that prepare lysates, extracts and assay plates for PCR, proteomics and cell-based work.
Keep samples cold, use short pulses or chilled bead-mill blocks, add a denaturing lysis buffer immediately, and use nuclease-free tubes and beads. Limit processing time, because heat and prolonged shear increase RNase activity and fragmentation. Verify integrity afterwards using an RNA integrity number or electrophoresis.
RPM is rotor rotational speed, whereas RCF expresses the actual force on the sample and depends on rotor radius. RCF equals 1.118 × 10⁻⁵ × radius in cm × RPM². Protocols should specify RCF so results remain reproducible across different centrifuge and rotor models.