Multi-Station Static Volumetric BET Surface Area Analyzer for Powders
多工位静态容量法粉体 BET 比表面积分析仪
- CE (to be confirmed)
- +1
Welcome to Lab Manufacturers China — laboratory instruments direct from a Chinese manufacturer

粉体质控单点流动法 BET 比表面积分析仪
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
| Measurement principle | Dynamic flow, TCD detection |
|---|---|
| Specific surface area range | 0.1–2000 m²/g |
| Stations | 2–4 |
| Gas mixture | N₂/He, 30% N₂ typical |
| Repeatability | ≤ 1.5% RSD |
| Accuracy | ± 2% vs reference material |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 9277, ASTM D3663, ASTM C204
A dynamic flow analyzer that measures nitrogen adsorption from a helium mixture with a thermal conductivity detector, producing single-point or few-point BET values in minutes. It suits routine quality control of powders such as pigments, carbon black, silica and catalysts with specified surface area windows.
A dynamic flow analyzer that measures nitrogen adsorption from a helium mixture with a thermal conductivity detector, producing single-point or few-point BET values in minutes. It suits routine quality control of powders such as pigments, carbon black, silica and catalysts with specified surface area windows.
A single-point flow instrument passes a nitrogen–helium mixture of known composition, typically 30 percent nitrogen, through the sample tube. When the tube is cooled in liquid nitrogen, nitrogen adsorbs and the thermal conductivity detector registers a peak; on warming, desorption gives a second peak whose area is calibrated with injected gas volumes. The single-point BET equation, valid when the C constant is large, converts the result to specific surface area. The method is quick, often under 10 minutes per sample after degassing, and requires no vacuum pumps or accurate pressure measurement. It supplies up to four stations for throughput. The accuracy for high-C materials is typically within 2 to 3 percent of multipoint results, but for microporous or low-C materials the single-point assumption fails and a multipoint system is needed.
Gas adsorption methods expose a degassed powder to nitrogen at 77 K. Adsorbed gas quantity is measured at several relative pressures, and the Brunauer–Emmett–Teller (BET) equation converts the monolayer capacity into surface area using the molecular cross-sectional area of nitrogen, 0.162 nm². Static volumetric systems dose known gas volumes and calculate uptake from pressure changes. Dynamic flow systems pass a nitrogen–helium mixture over the sample and detect adsorption and desorption by a thermal conductivity detector. Air permeability methods, such as Blaine or Fisher-type apparatus, measure the resistance to airflow through a packed powder bed of defined porosity, and the Kozeny–Carman relation gives specific surface area. Key components include sample tubes, degassing stations, pressure transducers, Dewar flask or cryogenic bath, and calibrated volumes.
A typical single-point flow bet surface area analyzer for powder qc configuration offers measurement principle of Dynamic flow, TCD detection, specific surface area range of 0.1–2000 m²/g, stations of 2–4, gas mixture of N₂/He, 30% N₂ typical, repeatability of ≤ 1.5% RSD and accuracy of ± 2% vs reference material. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
The Single-Point Flow BET Surface Area Analyzer for Powder QC is used in carbon black and silica QC, pigment and filler batch release, catalyst and alumina support checks, battery active material screening and cement additive incoming inspection. Across the wider Surface Area Analyzers class, laboratories also deploy it for cement fineness control, battery electrode and cathode powders and catalyst supports and activated carbon.
Relevant standards and methods include ISO 9277, ASTM D3663, ASTM C204, EN 196-6, ASTM D6556, ISO 15901-2 and GB/T 19587. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Sample preparation strongly affects surface area. Degas powders at a temperature and time that remove moisture and volatiles without altering the structure, and use the same protocol for every batch. Weigh samples accurately after degassing, because mass error transfers directly to the result. Keep the cryogenic bath level and cold trap stable, use high-purity nitrogen and helium, and check for leaks. Verify calibration with certified reference materials of known surface area. For air permeability, control bed porosity, temperature and humidity, and calibrate with a reference powder. Record degassing conditions and the BET pressure range in reports, and follow IQ/OQ/PQ practice where regulated.
Select this variant when routine batch release demands fast, low-cost surface area checks on materials with a known BET C constant. Specify the expected surface area range, number of stations, sample type, degassing needs and whether multipoint capability is also required. For microporous or research work, use a static volumetric system.
Choose according to the material and the decision that depends on the result. Cement and fine powders in production control are commonly measured by air permeability because it is fast and standardised. Nanopowders, catalysts supports and battery materials need gas adsorption to capture surfaces that permeability cannot. Single-point flow instruments give quick QC numbers, while multipoint static systems provide a full BET isotherm and validate linearity and C constant. Consider the expected surface area range, because materials under 1 m²/g require krypton or larger sample masses. Check the number of stations, degassing capability, liquid nitrogen handling, and whether results must follow ISO 9277 or ASTM D3663. Software features for automatic BET range selection per ISO 9277 and Rouquerol criteria reduce operator bias.
| Measurement principle | Dynamic flow, TCD detection |
|---|---|
| Specific surface area range | 0.1–2000 m²/g |
| Stations | 2–4 |
| Gas mixture | N₂/He, 30% N₂ typical |
| Repeatability | ≤ 1.5% RSD |
| Accuracy | ± 2% vs reference material |
| Analysis time | ≈ 6–10 min per sample |
| Degassing temperature | Ambient–350 °C |
| Sample tube | Glass, 6–9 mm |
| Sample mass | 0.05–2 g |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
For materials with a high C constant, where the isotherm passes close to the origin, single-point values typically agree with multipoint BET within about 2 to 3 percent. Accuracy falls for microporous materials and low-C surfaces.
Yes. The sample tube is immersed in a liquid nitrogen Dewar to adsorb nitrogen at 77 K, then removed to desorb. A steady supply and careful handling are required.
No. The flow method yields total surface area only, without full adsorption and desorption isotherms. Pore size distribution needs a static volumetric analyzer with multipoint isotherm capability.
BET surface area is the specific surface area of a material calculated from nitrogen adsorption isotherm data using the Brunauer–Emmett–Teller model. It is expressed in m²/g and includes accessible external and pore surface for the probe molecule.
Blaine fineness is determined by air permeability and reflects the external surface of a packed bed, typically 250 to 500 m²/kg for cement. BET uses gas adsorption and also measures internal and rough surfaces, so values are higher.
Adsorbed water and volatiles block surface sites and would be released during measurement, distorting results. Degassing under vacuum or flowing gas at an appropriate temperature cleans the surface without damaging the sample.