Inline Rheometer for Polymer Extrusion Monitoring
挤出在线流变仪
- SKU RHE-0006
- Rheometers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Maximum pressure | Up to 500 bar |
|---|---|
| Temperature range | Ambient to 400 °C |
| Shear rate range | 10–5000 s⁻¹ |
| Viscosity measuring range | 10–10⁵ Pa·s |
| Sample flow rate | 0.5–20 cm³/min with gear pump |
| Pressure transducer accuracy | ±0.5% of full scale |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 3219, ISO 11443, ISO 6721-10
What is the Inline Rheometer for Polymer Extrusion Monitoring?
An inline rheometer measures melt viscosity directly in an extruder flow stream, giving continuous or sampled data for closed-loop process control. It is specified when production consistency must be maintained automatically rather than checked afterwards in the laboratory.
What is the Inline Rheometer for Polymer Extrusion Monitoring?
An inline rheometer measures melt viscosity directly in an extruder flow stream, giving continuous or sampled data for closed-loop process control. It is specified when production consistency must be maintained automatically rather than checked afterwards in the laboratory.
Overview
Inline instruments are mounted in a bypass line, a die adaptor or a gear-pump branch of the extruder, so a small, representative stream of melt passes through the measuring channel. Most designs use a capillary or slit geometry with pressure transducers and a known throughput, from which shear stress and shear rate are calculated, while melt temperature is measured by an embedded probe. Some units use a small gear pump to meter the sample, which removes the influence of extruder pressure fluctuations and gives a stable shear rate. Outputs include melt viscosity index, pressure and temperature, which can be fed to a controller that adjusts screw speed or barrel temperatures. The measurement point is fixed, so the technique complements rather than replaces laboratory rheometry across a full flow curve.
How does it work?
A rheometer applies a controlled deformation to a polymer sample and measures the resulting force or torque. Rotational instruments use parallel plates, cones or concentric cylinders and can work in steady shear, giving shear viscosity against shear rate, or in oscillation, giving storage and loss moduli against frequency. Capillary instruments force melt through a die of known diameter and length at a controlled piston speed, measuring pressure to calculate apparent shear viscosity at shear rates that reach those of real extrusion. Torque rheometers mix material in a heated chamber and record the torque needed to turn the rotors, which tracks gelation, fusion and degradation in a compounding context. The choice depends on the shear rate range, the sample form and whether elasticity or only viscosity is required.
What are the key features?
- Bypass or die-adaptor mounting on the extruder
- Capillary or slit measuring channel with pressure transducers
- Optional gear pump for stable shear rate
- Continuous melt temperature measurement
- Signal output for closed-loop control
- High-pressure construction rated to process pressures
What are the technical specifications?
A typical inline rheometer for polymer extrusion monitoring configuration offers maximum pressure of Up to 500 bar, temperature range of Ambient to 400 °C, shear rate range of 10–5000 s⁻¹, viscosity measuring range of 10–10⁵ Pa·s, sample flow rate of 0.5–20 cm³/min with gear pump and pressure transducer accuracy of ±0.5% of full scale. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Inline Rheometer for Polymer Extrusion Monitoring is used in closed-loop control of extrusion viscosity, continuous monitoring of filled compound consistency, recycled polymer feed quality tracking and die and screw wear detection over time. Across the wider Rheometers class, laboratories also deploy it for molecular weight and molecular weight distribution comparison, processing behaviour prediction for extrusion and moulding and filler and additive effect on melt viscosity.
Which standards and certifications apply?
Relevant standards and methods include ISO 3219, ISO 11443, ISO 6721-10, ASTM D3835, ASTM D4440, ASTM D2538 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Sample preparation dominates repeatability: dry hygroscopic polymers, compression-mould discs of defined thickness for rotational testing, and ensure filled samples are homogeneous. Set the gap and check it with a zero-gap routine before each series, because a small gap error changes the calculated viscosity. In capillary work, verify piston speed and pressure transducer calibration, and apply the Bagley and Rabinowitsch corrections when true viscosity is required. Purge the oven with nitrogen for high-temperature or oxidation-sensitive polymers. Clean dies and plates thoroughly, since degraded residue changes the surface and the measured torque, and record temperature, geometry and gap with every result.
How do I select the right Inline Rheometer for Polymer Extrusion Monitoring?
Select an inline rheometer when production consistency needs continuous verification and the process has some adjustable parameter, such as screw speed, that a controller can act on. Specify the pressure and temperature ratings from the extruder line rather than from laboratory conditions, and decide whether a metering gear pump is justified, since it improves stability but adds a maintenance item. Plan how the instrument is cleaned on material changes.
How does it compare with other Rheometers variants?
Match the instrument to the shear rate range that governs your process. Rotational rheometers cover low shear rates and are the only option when viscoelastic data, yield stress or normal force are required, making them suitable for molecular weight comparisons and additive studies. Capillary rheometers reach the high shear rates of extrusion and injection moulding and are more tolerant of filled and highly viscous materials. Torque rheometers are used when the question concerns compounding behaviour, gelation or thermal stability under shear rather than a fundamental viscosity value. Inline instruments are selected for continuous process monitoring and never replace laboratory characterisation, because they see only one fixed measurement point.
Full specifications
| Maximum pressure | Up to 500 bar |
|---|---|
| Temperature range | Ambient to 400 °C |
| Shear rate range | 10–5000 s⁻¹ |
| Viscosity measuring range | 10–10⁵ Pa·s |
| Sample flow rate | 0.5–20 cm³/min with gear pump |
| Pressure transducer accuracy | ±0.5% of full scale |
| Melt temperature accuracy | ±1 °C |
| Output signal | 4–20 mA or digital bus |
| Wetted materials | Hardened or corrosion-resistant steel |
| Mounting | Bypass line, die adaptor or gear pump branch |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Closed-loop control of extrusion viscosity
- Continuous monitoring of filled compound consistency
- Recycled polymer feed quality tracking
- Die and screw wear detection over time
Key features
- Bypass or die-adaptor mounting on the extruder
- Capillary or slit measuring channel with pressure transducers
- Optional gear pump for stable shear rate
- Continuous melt temperature measurement
- Signal output for closed-loop control
- High-pressure construction rated to process pressures
Frequently asked questions about Inline Rheometer for Polymer Extrusion Monitoring
Extruder pressure and output fluctuate with screw geometry and feed variation, and an unstable flow rate means an unstable apparent shear rate. A metering gear pump delivers a constant volume per revolution, so the shear rate becomes defined and the pressure signal reflects viscosity rather than throughput noise.
No. An inline instrument measures at one fixed shear rate and temperature, so it is a trend and control signal rather than a full characterisation. Laboratory rheometry still provides flow curves, viscoelastic data and method compliance, and the two should be correlated so that inline limits correspond to acceptable laboratory values.
The measuring channel should be purged at every material change and inspected at planned shutdowns, because degraded polymer in the bypass line changes the effective geometry and biases the reading. Purge with a compatible cleaning compound at process temperature and confirm that pressure returns to the expected baseline value on restart.
A rotational rheometer measures viscosity in steady or oscillatory shear at low shear rates, where the material response is dominated by molecular relaxation. A capillary rheometer measures at high shear rates that match extrusion and injection moulding. The two techniques overlap in a mid-range and should agree after corrections, but each covers a shear rate window the other cannot reach.
Viscosity is calculated from measured torque, angular velocity and the gap between the geometries, so an error in gap propagates directly into the result. Compression of the sample and thermal expansion change the effective gap, which is why a zero-gap routine and a constant sample thickness are used before each series.
They can, but filler particles may slip at the plate surface, settle, or bridge the gap, so the measured viscosity can be too low. Practical measures are to use serrated or roughened plates, larger gaps, and lower filler loadings where possible, and to compare results only between samples of the same filler content and particle size.
Related models