FTIR Oil Condition Analyzer
FTIR 油液状态分析仪
- SKU OIA-0003
- Oil Analysis
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Spectral range | 4000–650 cm-1 |
|---|---|
| Spectral resolution | 4 cm-1 |
| Cell path length | ≈ 100 µm (transmission) or ATR |
| Detector | DTGS |
| Signal-to-noise ratio | > 20,000:1 (peak-to-peak, 1 min) |
| Sample volume | ≈ 2–3 mL |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM D5185, ASTM D6595, ASTM E2412
What is the FTIR Oil Condition Analyzer?
An FTIR oil condition analyzer measures infrared absorbance of used oil in a thin cell to report oxidation, nitration, soot, sulfation, glycol and water. It is the most common first-line screening tool for engine and gearbox oil programs.
What is the FTIR Oil Condition Analyzer?
An FTIR oil condition analyzer measures infrared absorbance of used oil in a thin cell to report oxidation, nitration, soot, sulfation, glycol and water. It is the most common first-line screening tool for engine and gearbox oil programs.
Overview
The analyzer passes a mid-infrared beam through a thin oil film in a transmission flow cell or over an attenuated total reflectance crystal. An interferometer scans all wavenumbers simultaneously, and Fourier transformation produces an absorbance spectrum from about 4000 to 650 cm-1. Software subtracts the fresh-oil reference and integrates defined regions: carbonyl absorption near 1710 cm-1 for oxidation, near 1630 cm-1 for nitration, sulfate bands for sulfation, and broad baseline rise for soot. Glycol and water are identified by their hydroxyl bands. Analysis takes under one minute with a few milliliters of sample and no chemicals. Trending is done against the unit's own new-oil spectrum, and methods follow ASTM E2412 and ASTM D7414, D7415 and D7844.
How does it work?
Oil analysis combines several measurement principles, each targeting a different failure indicator. Atomic emission spectrometry, using plasma or an arc-spark source, excites metal atoms in a diluted or neat sample and reads emission lines at characteristic wavelengths to give iron, copper, aluminum and additive concentrations. Fourier transform infrared spectroscopy measures absorbance of oil in a thin transmission cell and calculates soot, oxidation, nitration, sulfation, glycol and water from defined spectral regions. Laser light-extinction counters size and count particles as they pass a detection cell at a controlled flow rate. Potentiometric titration follows the electrode potential while a reagent is added, locating the endpoints for acid and base number. Together these methods describe wear, contamination and chemical condition.
What are the key features?
- Interferometer with temperature-controlled flow cell or ATR crystal
- Automated oxidation, nitration, sulfation and soot calculations
- Sample analysis in under one minute without reagents
- Library of new-oil reference spectra for trending
- Autosampler option for unattended batch runs
What are the technical specifications?
A typical ftir oil condition analyzer configuration offers spectral range of 4000–650 cm-1, spectral resolution of 4 cm-1, cell path length of ≈ 100 µm (transmission) or ATR, detector of DTGS, signal-to-noise ratio of > 20,000:1 (peak-to-peak, 1 min) and sample volume of ≈ 2–3 mL. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The FTIR Oil Condition Analyzer is used in engine oil condition screening, gearbox and compressor oil monitoring and fuel and glycol contamination detection. Across the wider Oil Analysis class, laboratories also deploy it for used-oil wear metal analysis, new oil additive verification and hydraulic fluid cleanliness control.
Which standards and certifications apply?
Relevant standards and methods include ASTM D5185, ASTM D6595, ASTM E2412, ASTM D7889, ASTM D7647, ISO 4406, ASTM D664 and ASTM D2896. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place spectrometers on a stable bench with controlled temperature, ventilation for exhaust and a clean argon supply where required. Calibrate with certified oil-based standards and verify with a check sample at the start of each batch. Keep sample bottles clean and homogenize samples by shaking or ultrasonic mixing before analysis, since settling biases metal results. Replace pump tubing, nebulizer parts, electrodes and optical windows on the manufacturer's schedule. Record results with sample ID, unit hours and oil age so trends can be evaluated. Follow local rules for waste solvent and used-oil disposal.
How do I select the right FTIR Oil Condition Analyzer?
Select an FTIR analyzer for fast chemical screening of used oil where wear metals are covered by another instrument. It is the lowest operating-cost option in this category. In an RFQ, specify transmission or ATR cell, autosampler need, reference library support and compliance with ASTM E2412 or D7414-type methods.
How does it compare with other Oil Analysis variants?
Choose the variant from the question you need answered. Elemental spectrometers answer wear and additive depletion questions; ICP-OES handles dissolved metals and larger particles after digestion or dilution, while RDE-OES is faster and needs no sample preparation but under-reads particles above a few micrometers. FTIR answers chemical degradation and contamination questions and is usually the most cost-effective first screen. Particle counters address cleanliness codes for hydraulic and turbine systems. Titrators cover acid and base number for oils with additive packages. Consider daily sample volume, required method (ASTM D5185, D7889, D7647, D664), operator skill, consumables such as argon and solvents, and whether your laboratory reports to customer-defined alarm limits.
Full specifications
| Spectral range | 4000–650 cm-1 |
|---|---|
| Spectral resolution | 4 cm-1 |
| Cell path length | ≈ 100 µm (transmission) or ATR |
| Detector | DTGS |
| Signal-to-noise ratio | > 20,000:1 (peak-to-peak, 1 min) |
| Sample volume | ≈ 2–3 mL |
| Analysis time | ≈ 30–60 s |
| Parameters reported | Oxidation, nitration, sulfation, soot, glycol, water |
| Power supply | 100–240 V AC, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Engine oil condition screening
- Gearbox and compressor oil monitoring
- Fuel and glycol contamination detection
Key features
- Interferometer with temperature-controlled flow cell or ATR crystal
- Automated oxidation, nitration, sulfation and soot calculations
- Sample analysis in under one minute without reagents
- Library of new-oil reference spectra for trending
- Autosampler option for unattended batch runs
Frequently asked questions about FTIR Oil Condition Analyzer
FTIR reports oxidation, nitration, sulfation, soot, glycol, water and fuel dilution indicators from absorbance bands. It shows chemical degradation and contamination but not wear metal concentrations, so it is usually paired with an elemental spectrometer.
Absorbance values depend on the oil formulation. Subtracting the unit's own fresh-oil spectrum isolates changes caused by service, so oxidation or nitration readings reflect actual degradation rather than base-oil and additive differences.
FTIR results are quantitative in arbitrary absorbance units per cm or in percent for some parameters, calibrated for trending. They are not absolute concentrations comparable across oil types, so alarm limits should be set per oil and application.
Oil analysis measures wear metals, additive elements, contaminants such as water, fuel, soot and glycol, particle counts, viscosity and acid or base number. Together these indicators show machine wear, oil degradation and contamination sources, allowing maintenance decisions to be based on data rather than fixed drain intervals.
Wear metals in used oil are usually determined by ICP-OES following ASTM D5185 or by rotating disk electrode optical emission spectrometry following ASTM D6595. Both report iron, copper, lead, aluminum and other elements in mg/kg, with differences in particle-size response.
Scheduled sampling builds a trend for each machine. A single result may be normal, but a rising iron or oxidation trend shows developing wear or degradation early. Consistent sampling points, intervals and methods are what make the trend reliable.