Fluorescence Microplate Reader for Nucleic Acid Quantification
核酸定量用荧光微孔板读数仪
- SKU NUC-0004
- Nucleic Acid Analysis
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 test report (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Plate formats | 96 and 384 well |
|---|---|
| Excitation range | 400-700 nm, filter or monochromator |
| Emission range | 420-760 nm |
| Detection limit | 0.2-1 ng/mL with high-sensitivity kit |
| Sample volume | 2-20 µL per well |
| Throughput | 96 wells in 1-3 min |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 20395, ISO 13485 manufacturing, MIQE guidelines
What is the Fluorescence Microplate Reader for Nucleic Acid Quantification?
A plate reader that quantifies DNA or RNA in 96 or 384 wells with dye chemistry, giving high throughput and low sample use. It suits laboratories normalising hundreds of samples per day.
What is the Fluorescence Microplate Reader for Nucleic Acid Quantification?
A plate reader that quantifies DNA or RNA in 96 or 384 wells with dye chemistry, giving high throughput and low sample use. It suits laboratories normalising hundreds of samples per day.
Overview
The fluorescence plate reader measures dye-based nucleic acid assays in multi-well plates, using top or bottom optics, monochromators or filter sets, and flash xenon or LED excitation with photomultiplier detection. Standard curves are prepared in the same plate as the samples, and software interpolates concentration, flags wells outside the linear range and reports plate maps. With 96 or 384 wells, a single run quantifies a few hundred samples in a few minutes, consuming 2 to 20 µL of sample per well, which suits automated workflows that normalize libraries or templates for qPCR panels. Sensitivity is comparable to single-tube fluorometers, and cross-talk between adjacent wells is low because excitation and emission filters are matched to the dye. Some models also offer absorbance mode for A260 measurement or for colorimetric assays.
How does it work?
Two measurement principles dominate. Absorbance analysis uses a 1 mm or 0.5 mm pathlength in a microvolume cell and reads at 260 nm, where nucleic acids absorb strongly, then scales the result to a standard 10 mm path. A260 of 1.0 corresponds to about 50 µg/mL double-stranded DNA, 33 µg/mL single-stranded DNA and 40 µg/mL RNA, and ratios at 260/280 and 260/230 indicate protein or salt contamination. Fluorescence methods use dyes that bind specifically to double-stranded DNA or to total RNA, so signal comes only from the target, which makes them more tolerant of protein, salts and free nucleotides. Capillary electrophoresis separates fragments in a sieving polymer and reports sizes in base pairs together with molarity. Automated workstations combine measurement with pipetting so samples can be diluted to a target concentration.
What are the key features?
- 96 or 384 well format for hundreds of samples per run.
- Filter or monochromator optics matched to common dyes.
- Standards and samples measured on the same plate.
- Sample consumption of 2 to 20 µL per well.
- Software with standard curve fitting and range flags.
- Optional absorbance mode for A260 or colorimetric assays.
What are the technical specifications?
A typical fluorescence microplate reader for nucleic acid quantification configuration offers plate formats of 96 and 384 well, excitation range of 400-700 nm, filter or monochromator, emission range of 420-760 nm, detection limit of 0.2-1 ng/mL with high-sensitivity kit, sample volume of 2-20 µL per well and throughput of 96 wells in 1-3 min. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Fluorescence Microplate Reader for Nucleic Acid Quantification is used in batch normalisation of qPCR templates, sequencing library pooling quantification, screening hundreds of extraction products and plant and seed genotyping sample checks. Across the wider Nucleic Acid Analysis class, laboratories also deploy it for next-generation sequencing library quality control, template quantification before qPCR and plasmid and oligonucleotide quality checks.
Which standards and certifications apply?
Relevant standards and methods include ISO 20395, ISO 13485 manufacturing, MIQE guidelines, CLSI MM06-A2, IEC 61010-1 and IVDR (EU) 2017/746. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 test report; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Blank the instrument with the same buffer as the sample, because buffer absorbance differs and elution buffers containing guanidine or EDTA give misleading ratios. Keep the measurement pedestal clean and wipe it between samples to avoid carryover, and check microvolume accuracy with a reference standard periodically. Fluorescent assays need fresh standards and protection of dye reagents from light, and dye-based concentration depends on assay chemistry, so do not compare results from different kits. For fragment analysis, follow the vendor's sample and ladder preparation closely, since ionic strength affects injection. Store eluted nucleic acids cold, avoid repeated freeze-thaw, and record concentration, ratios and method with every sample.
How do I select the right Fluorescence Microplate Reader for Nucleic Acid Quantification?
Select the plate reader when hundreds of samples must be quantified daily and plate-based automation is already in place. Compare filter or monochromator flexibility, detection limit and cross-talk performance, and confirm that the software exports concentrations in a format your normalisation workflow can use. Check plate types and whether absorbance mode is needed.
How does it compare with other Nucleic Acid Analysis variants?
Choose the method by how much selectivity you need. Absorbance is fast, inexpensive and sufficient for routine plasmid or PCR checks, but it cannot distinguish DNA from RNA and is affected by protein, phenol and salts. Fluorescence dyes are selective for double-stranded DNA or RNA and need as little as a few picograms, which suits sequencing libraries and low-yield samples. Capillary electrophoresis adds size and integrity information that no spectrophotometer provides, which matters for library insert size and RNA integrity. Throughput then decides between single-tube devices, microplate readers and automated workstations that combine measurement with normalisation. Check the minimum sample volume, detection limit, linear range, required standards and the export format your data system accepts.
Full specifications
| Plate formats | 96 and 384 well |
|---|---|
| Excitation range | 400-700 nm, filter or monochromator |
| Emission range | 420-760 nm |
| Detection limit | 0.2-1 ng/mL with high-sensitivity kit |
| Sample volume | 2-20 µL per well |
| Throughput | 96 wells in 1-3 min |
| Optical path | Top and bottom reading |
| Well cross-talk | Below 0.5 percent with matched filters |
| Modes | Fluorescence, optional absorbance |
| Power supply | 100-240 V, 50/60 Hz, 100-200 W |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Batch normalisation of qPCR templates
- Sequencing library pooling quantification
- Screening hundreds of extraction products
- Plant and seed genotyping sample checks
Key features
- 96 or 384 well format for hundreds of samples per run.
- Filter or monochromator optics matched to common dyes.
- Standards and samples measured on the same plate.
- Sample consumption of 2 to 20 µL per well.
- Software with standard curve fitting and range flags.
- Optional absorbance mode for A260 or colorimetric assays.
Frequently asked questions about Fluorescence Microplate Reader for Nucleic Acid Quantification
A plate reader quantifies 96 or 384 samples in one run of one to three minutes, while a tube fluorometer typically handles one sample at a time. For large batches the plate format saves substantial labour.
Bottom optics reduce interference from meniscus effects and from the plate lid, and they suit clear-bottom plates. Top reading is used for opaque plates or when the dye signal is strongly absorbed by plastic.
Filters give higher sensitivity and lower cost for fixed dye sets, while monochromators allow arbitrary wavelengths for assay development. Laboratories running established kits usually choose filters.
A260/280 near 1.8 for DNA and 2.0 for RNA indicates low protein contamination, while A260/230 above about 2.0 suggests little carryover of salts, phenols or guanidine. Values well below these ranges usually mean the sample needs repurification.
Use fluorescence when the sample is scarce, when the template contains protein, phenol or free nucleotides, or when only double-stranded DNA should be measured. Dyes such as PicoGreen or RiboGreen report the target specifically, so values are less affected by contaminants.
For sequencing libraries, RNA samples and amplicon panels, yes. Concentration alone cannot show whether a library insert is the correct length or whether RNA is degraded, and those properties determine sequencing and qPCR performance.