Filter Weighing Microbalance with Conditioning Chamber
带恒温恒湿腔的滤膜称量微量天平
- SKU MCR-0004
- Microbalances
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- Environmental method conformity (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Balance readability | 1 µg |
|---|---|
| Balance capacity | 6–52 g |
| Chamber temperature setpoint | 20–23 C |
| Temperature stability | ±1 C |
| Humidity setpoint | 30–40% RH |
| Humidity stability | ±5% RH |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <41>, USP <1251>, OIML R 76-1
What is the Filter Weighing Microbalance with Conditioning Chamber?
A filter weighing microbalance system combines a 1 microgram balance with a temperature- and humidity-controlled chamber for equilibrating and weighing particulate filters. It is used for gravimetric PM2.5 and PM10 determinations and occupational dust sampling.
What is the Filter Weighing Microbalance with Conditioning Chamber?
A filter weighing microbalance system combines a 1 microgram balance with a temperature- and humidity-controlled chamber for equilibrating and weighing particulate filters. It is used for gravimetric PM2.5 and PM10 determinations and occupational dust sampling.
Overview
Gravimetric particulate methods require filters to be conditioned at a stable temperature and humidity, for example 20 to 23 C and 30 to 40 percent relative humidity for EPA methods, before weighing. This system pairs a microbalance of 1 microgram readability with an enclosure or glovebox that controls climate, often with a polonium-free static neutralizer. Filters of 37 to 47 mm or larger sit on racks during a 24-hour equilibration, and the balance sits inside or alongside the chamber with transfer ports. Temperature stability of ±1 C and humidity stability of ±5 percent are typical. Software records filter ID, conditions, tare and gross weights for traceability. Weighing the same filter before and after sampling gives the collected mass.
How does it work?
Microbalances use electromagnetic force compensation with a very high-resolution weighing cell, often a monolithic flexure system with optical position sensing. The load on the pan is opposed by a coil current, and the current is digitized by a low-noise converter to resolve 0.1 to 1 microgram. Because such small masses are disturbed by air currents, temperature gradients, static charge and buoyancy, the pan sits in a small enclosed chamber with glass or metal walls, often with side doors closed by motor. The cell is thermally insulated, and an internal reference weight allows automatic adjustment. Electronic filters average readings to suppress vibration noise, and the system usually sits on a heavy stone or anti-vibration table to isolate it from floor movement.
What are the key features?
- Temperature and humidity controlled conditioning chamber for filters
- 1 microgram balance with static neutralizer for filter weighing
- Filter racks for 24-hour equilibration of 37 to 47 mm filters
- Logging of temperature, humidity, tare and gross weights
- Transfer ports or glovebox to avoid disturbing the climate
What are the technical specifications?
A typical filter weighing microbalance with conditioning chamber configuration offers balance readability of 1 µg, balance capacity of 6–52 g, chamber temperature setpoint of 20–23 C, temperature stability of ±1 C, humidity setpoint of 30–40% RH and humidity stability of ±5% RH. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Filter Weighing Microbalance with Conditioning Chamber is used in ambient PM2.5 and PM10 gravimetric analysis, occupational dust sampling, stack emission particulate testing and research on aerosol filter loading. Across the wider Microbalances class, laboratories also deploy it for filter weighing for particulate matter, reference standard weighing and thin-film and coating mass determination.
Which standards and certifications apply?
Relevant standards and methods include USP <41>, USP <1251>, OIML R 76-1, OIML R 111-1, Ph. Eur. 2.1.7, 40 CFR Part 50 Appendix L and ISO 9001. Certification candidates for this model are CE, ISO 9001 manufacturing and Environmental method conformity; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Microbalances need a dedicated weighing room or bench with vibration isolation, stable temperature within about 0.5 K per hour, and relative humidity of 40 to 60 percent. Keep the balance away from drafts, radiators and foot traffic. Allow several hours of warm-up after power-up and equilibrate samples and weighing vessels in the room before weighing. Control static charge with ionizers, since it is a dominant error source. Use tweezers or gloves, never bare fingers. Calibrate and adjust internally, verify with micro-weights of class E1 or better, and arrange regular accredited service. Keep records of routine tests, since minimum weight varies with environment.
How do I select the right Filter Weighing Microbalance with Conditioning Chamber?
Select this system for regulatory or research gravimetric filter programs that require controlled conditioning. Standalone microbalances lack climate control. In the RFQ, specify filter sizes and numbers, climate setpoints, data logging, ionizer type and the method being followed.
How does it compare with other Microbalances variants?
Start with the smallest sample mass and the tolerance required, then compute the minimum weight from the balance's repeatability. Readability of 1 microgram suits most filter and standard weighing, while 0.1 microgram ultra-micro balances are needed for trace samples or very tight tolerances. Capacity is usually 2 to 6 g for ultra-micro and up to 52 g for micro models, and higher capacity comes at reduced resolution. Consider static control, the need for a conditioned chamber for filters, and automation such as sample changers. The installation site is decisive: low vibration, stable temperature within 0.5 K per hour and controlled humidity. Check also calibration options, data-integrity software and whether pharmacopoeial or EPA method requirements apply.
Full specifications
| Balance readability | 1 µg |
|---|---|
| Balance capacity | 6–52 g |
| Chamber temperature setpoint | 20–23 C |
| Temperature stability | ±1 C |
| Humidity setpoint | 30–40% RH |
| Humidity stability | ±5% RH |
| Filter capacity | 50–200 filters |
| Static control | Polonium-free ionizer |
| Data logging | Temperature, RH, weights |
| Interfaces | USB, Ethernet |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Ambient PM2.5 and PM10 gravimetric analysis
- Occupational dust sampling
- Stack emission particulate testing
- Research on aerosol filter loading
Key features
- Temperature and humidity controlled conditioning chamber for filters
- 1 microgram balance with static neutralizer for filter weighing
- Filter racks for 24-hour equilibration of 37 to 47 mm filters
- Logging of temperature, humidity, tare and gross weights
- Transfer ports or glovebox to avoid disturbing the climate
Frequently asked questions about Filter Weighing Microbalance with Conditioning Chamber
Filters and collected particles absorb and release moisture depending on humidity and temperature. Conditioning for typically 24 hours at stable conditions brings them to equilibrium so the pre-sampling and post-sampling weights are comparable.
US EPA reference methods for PM2.5 under 40 CFR Part 50, European EN 12341 for PM10 and PM2.5, and NIOSH or OSHA gravimetric dust methods all rely on controlled filter weighing. Verify requirements in the method you follow.
Not necessarily. Polonium-210 sources were traditionally used, but they have a short service life and regulatory burden. Electrical corona ionizers achieve similar neutralization without radioactive material and are now widely used.
A microbalance reads to 1 microgram or finer, while an analytical balance reads to 0.1 mg (100 micrograms) or 0.01 mg. Microbalances handle small samples but have lower capacity, demand much more stable installation and need stricter control of static and temperature.
Electrostatic forces between a charged sample or vessel and the balance walls act like additional mass, producing drifting or wrong readings of tens of micrograms. Ionizers, conductive vessels and humidity above 40 percent reduce the effect.
Yes. Air density varies with temperature, pressure and humidity, changing buoyancy on samples of different density. For high-accuracy work, apply buoyancy corrections or weigh samples and reference weights of similar density, particularly for filters.