Standard Microbalance (1 µg)
标准微量天平(1 µg)
- SKU MCR-0002
- Microbalances
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- OIML R 76 type approval (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Readability | 1 µg |
|---|---|
| Capacity | 6–52 g |
| Repeatability (SD) | ≈ 0.5–1.5 µg |
| Linearity | ±2–6 µg |
| Minimum weight (0.1% tolerance) | ≈ 1–3 mg |
| Stabilization time | ≈ 5–15 s |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <41>, USP <1251>, OIML R 76-1
What is the Standard Microbalance (1 µg)?
A standard microbalance reads to 1 microgram with capacities of about 6 to 52 g. It is the working class for filter weighing, reference standards and small-sample quantitative work in pharmaceutical, environmental and materials laboratories.
What is the Standard Microbalance (1 µg)?
A standard microbalance reads to 1 microgram with capacities of about 6 to 52 g. It is the working class for filter weighing, reference standards and small-sample quantitative work in pharmaceutical, environmental and materials laboratories.
Overview
The 1 microgram microbalance is the most common class of microbalance. A monolithic electromagnetic cell provides repeatability of about 0.5 to 1.5 micrograms with capacities between 6 and 52 g. The pan, typically 25 to 50 mm in diameter, sits in a closed chamber, and doors are usually motorized. Stabilization is 5 to 15 seconds. An internal calibration weight allows automatic adjustment, and a built-in level sensor guides installation. A static eliminator is an option or standard depending on model. Minimum weight at 0.1 percent tolerance is about 1 to 3 mg. It is more forgiving of site conditions than the 0.1 microgram class, although it still needs a low-vibration, temperature-stable room. The balance is often used for weighing samples in method development and research.
How does it work?
Microbalances use electromagnetic force compensation with a very high-resolution weighing cell, often a monolithic flexure system with optical position sensing. The load on the pan is opposed by a coil current, and the current is digitized by a low-noise converter to resolve 0.1 to 1 microgram. Because such small masses are disturbed by air currents, temperature gradients, static charge and buoyancy, the pan sits in a small enclosed chamber with glass or metal walls, often with side doors closed by motor. The cell is thermally insulated, and an internal reference weight allows automatic adjustment. Electronic filters average readings to suppress vibration noise, and the system usually sits on a heavy stone or anti-vibration table to isolate it from floor movement.
What are the key features?
- 1 microgram readability with capacity up to 52 g
- Enclosed chamber with motorized doors
- Internal calibration weight for automatic adjustment
- Electronic level sensor with on-screen guidance
- Static eliminator included or available as an option
What are the technical specifications?
A typical standard microbalance (1 µg) configuration offers readability of 1 µg, capacity of 6–52 g, repeatability (SD) of ≈ 0.5–1.5 µg, linearity of ±2–6 µg, minimum weight (0.1% tolerance) of ≈ 1–3 mg and stabilization time of ≈ 5–15 s. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Standard Microbalance (1 µg) is used in reference standard weighing, method development with small samples, filter and membrane weighing and catalyst weighing. Across the wider Microbalances class, laboratories also deploy it for filter weighing for particulate matter, reference standard weighing and thin-film and coating mass determination.
Which standards and certifications apply?
Relevant standards and methods include USP <41>, USP <1251>, OIML R 76-1, OIML R 111-1, Ph. Eur. 2.1.7, 40 CFR Part 50 Appendix L and ISO 9001. Certification candidates for this model are CE, ISO 9001 manufacturing and OIML R 76 type approval; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Microbalances need a dedicated weighing room or bench with vibration isolation, stable temperature within about 0.5 K per hour, and relative humidity of 40 to 60 percent. Keep the balance away from drafts, radiators and foot traffic. Allow several hours of warm-up after power-up and equilibrate samples and weighing vessels in the room before weighing. Control static charge with ionizers, since it is a dominant error source. Use tweezers or gloves, never bare fingers. Calibrate and adjust internally, verify with micro-weights of class E1 or better, and arrange regular accredited service. Keep records of routine tests, since minimum weight varies with environment.
How do I select the right Standard Microbalance (1 µg)?
Select the 1 microgram model for most microweighing tasks with samples above about 5 mg. It balances capacity, cost and site requirements better than an ultra-micro unit. In the RFQ, specify capacity, door type, ionizer, calibration and data interfaces.
How does it compare with other Microbalances variants?
Start with the smallest sample mass and the tolerance required, then compute the minimum weight from the balance's repeatability. Readability of 1 microgram suits most filter and standard weighing, while 0.1 microgram ultra-micro balances are needed for trace samples or very tight tolerances. Capacity is usually 2 to 6 g for ultra-micro and up to 52 g for micro models, and higher capacity comes at reduced resolution. Consider static control, the need for a conditioned chamber for filters, and automation such as sample changers. The installation site is decisive: low vibration, stable temperature within 0.5 K per hour and controlled humidity. Check also calibration options, data-integrity software and whether pharmacopoeial or EPA method requirements apply.
Full specifications
| Readability | 1 µg |
|---|---|
| Capacity | 6–52 g |
| Repeatability (SD) | ≈ 0.5–1.5 µg |
| Linearity | ±2–6 µg |
| Minimum weight (0.1% tolerance) | ≈ 1–3 mg |
| Stabilization time | ≈ 5–15 s |
| Calibration | Internal motorized |
| Pan size | Ø 25–50 mm |
| Operating temperature | 15–30 C |
| Interfaces | USB, RS-232 |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Reference standard weighing
- Method development with small samples
- Filter and membrane weighing
- Catalyst weighing
Key features
- 1 microgram readability with capacity up to 52 g
- Enclosed chamber with motorized doors
- Internal calibration weight for automatic adjustment
- Electronic level sensor with on-screen guidance
- Static eliminator included or available as an option
Frequently asked questions about Standard Microbalance (1 µg)
At 0.1 percent tolerance, the minimum weight is roughly 1 to 3 mg, derived from about 1000 times the repeatability. For looser tolerance, such as 1 percent, samples of a few hundred micrograms can be weighed, subject to site conditions.
Use a small tared vessel, such as an aluminum foil boat or weighing pan, to protect the balance and handle powders. Keep vessel, sample and balance at the same temperature to avoid convection errors.
Keep room relative humidity between about 40 and 60 percent and stable within a few percent. Lower humidity raises static, while higher humidity causes hygroscopic samples and filters to gain mass. A room humidifier or dehumidifier with monitoring is often used.
A microbalance reads to 1 microgram or finer, while an analytical balance reads to 0.1 mg (100 micrograms) or 0.01 mg. Microbalances handle small samples but have lower capacity, demand much more stable installation and need stricter control of static and temperature.
Electrostatic forces between a charged sample or vessel and the balance walls act like additional mass, producing drifting or wrong readings of tens of micrograms. Ionizers, conductive vessels and humidity above 40 percent reduce the effect.
Yes. Air density varies with temperature, pressure and humidity, changing buoyancy on samples of different density. For high-accuracy work, apply buoyancy corrections or weigh samples and reference weights of similar density, particularly for filters.