Key specifications
| Measurement range | 0–200,000 lx, auto-ranging |
|---|---|
| Accuracy | ±3% of reading |
| Sensor | Silicon photodiode with photopic filter |
| Cosine correction | Included |
| Resolution | 0.1 lx on low range |
| Display | 4-digit LCD |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO/CIE 19476, DIN 5032-7, CIE S 025
What is the Handheld Lux Meter?
A handheld lux meter is a compact, battery-powered photometer for quick illuminance checks. It is the standard tool for on-site lighting surveys, workplace inspections and verification that measured light levels meet a specified target.
What is the Handheld Lux Meter?
A handheld lux meter is a compact, battery-powered photometer for quick illuminance checks. It is the standard tool for on-site lighting surveys, workplace inspections and verification that measured light levels meet a specified target.
Overview
A handheld lux meter combines a photopic-filtered photodiode, a cosine-correcting diffuser and a digital display in an ergonomic body. Auto-ranging covers several decades of illuminance from below one lux to full daylight, and a hold function freezes readings for recording. Many models include min-max, average and relative measurement, and some offer a detached sensor on a cable so the display can be read while the sensor sits on the work plane. Accuracy is adequate for surveys and compliance checks. The instrument is inexpensive, robust and simple to operate, making it the first choice for routine lighting assessment.
How does it work?
A lux meter converts incident light into a photocurrent with a silicon photodiode covered by a filter that approximates the CIE photopic response, which matches the sensitivity of the human eye. The signal is amplified and scaled to give illuminance in lux, equal to lumens per square meter. A diffuser and cosine corrector ensure the reading follows the cosine law of incidence and is independent of the angle of arriving light. Because the eye response peaks in the green region near 555 nm, the filter strongly attenuates ultraviolet and infrared radiation. Calibration against a reference lamp or standard photometer sets the absolute scale, and the meter is classified by accuracy and stability according to photometric standards. Temperature and stray light affect reading stability.
What are the key features?
- Auto-ranging across low light to full daylight
- Cosine-corrected photopic-filtered sensor
- Data hold, min-max and average functions
- Detachable sensor option for remote placement
- Compact battery-powered housing
What are the technical specifications?
A typical handheld lux meter configuration offers measurement range of 0–200,000 lx, auto-ranging, accuracy of ±3% of reading, sensor of Silicon photodiode with photopic filter, cosine correction of Included, resolution of 0.1 lx on low range and display of 4-digit LCD. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Handheld Lux Meter is used in workplace lighting surveys, display screen brightness checks, greenhouse light level monitoring and educational and field measurements. Across the wider Lux Meters class, laboratories also deploy it for workplace and occupational lighting surveys, display and monitor brightness verification and greenhouse and plant growth lighting control.
Which standards and certifications apply?
Relevant standards and methods include ISO/CIE 19476, DIN 5032-7, CIE S 025, CIE 13.3 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Keep the photopic filter and diffuser clean and free of scratches, because contamination changes the response and biases readings. Zero the instrument in darkness where required, and verify periodically against a calibrated reference lamp or a meter of known accuracy. Avoid shading the sensor and measure at the working plane, holding the sensor in the same orientation as the surface of interest. Note ambient temperature and allow thermal equilibrium. Store meters with the sensor capped, and follow the calibration interval defined by the quality system, often annually.
How do I select the right Handheld Lux Meter?
Select a handheld lux meter for quick, mobile illuminance checks. Confirm the range covers both dim and bright conditions, that cosine correction is included, and that the accuracy suits the survey requirement. A detachable sensor and hold function are useful when taking readings at the working plane. For trend or compliance records, choose a model with memory or USB output.
How does it compare with other Lux Meters variants?
Choose a handheld lux meter for quick spot checks, surveys and field verification of lighting. Select a benchtop or logging model when measurements must be recorded, averaged or monitored over time. Match the measurement range to the space, since outdoor daylight can exceed 100,000 lux while corridors may be far below 100 lux. Confirm the cosine and colour correction, the stated accuracy class and the sensor calibration. For lighting design and colour work, a spectral illuminance meter adds colour temperature and colour rendering data. Check connectors or remote probes for hard-to-reach locations.
Full specifications
| Measurement range | 0–200,000 lx, auto-ranging |
|---|---|
| Accuracy | ±3% of reading |
| Sensor | Silicon photodiode with photopic filter |
| Cosine correction | Included |
| Resolution | 0.1 lx on low range |
| Display | 4-digit LCD |
| Sampling rate | 2.5 readings per second |
| Power supply | 9 V battery |
| Operating temperature | 0–50 °C |
| Data interface | Optional USB |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Workplace lighting surveys
- Display screen brightness checks
- Greenhouse light level monitoring
- Educational and field measurements
Key features
- Auto-ranging across low light to full daylight
- Cosine-corrected photopic-filtered sensor
- Data hold, min-max and average functions
- Detachable sensor option for remote placement
- Compact battery-powered housing
Frequently asked questions about Handheld Lux Meter
Hold the sensor at the working plane where the light level matters, for example desk height for office lighting or floor level for corridors. Its distance from a lamp does not need to be fixed, but the sensor should face the same direction as the surface being assessed and avoid shadowing.
Differences come from filter quality, cosine correction, calibration state and temperature. Lower-class instruments deviate more from the ideal photopic response and from the cosine law. For compliance work, use calibrated instruments of the required class and keep them under the same conditions.
Yes, most models have a low range down to about 0.1 lx or lower, suitable for emergency lighting and night-time checks. Readings at the lowest range are more sensitive to noise and stray light, so allow warm-up and shield the sensor from unintended sources.
Lumens measure the total light emitted by a source in all directions, while lux measure the light arriving per unit area at a surface. One lux equals one lumen per square meter. Illuminance depends on both the source output and the distance and geometry to the surface.
Light rarely arrives perpendicular to a surface. The cosine law predicts that illuminance falls with the cosine of the incidence angle. A cosine-corrected diffuser makes the meter follow this law, so readings remain accurate when the light arrives at an angle.
Photometric standards classify illuminance meters by properties such as response, cosine and linearity, from high-accuracy laboratory classes to general field classes. Laboratory work and compliance measurements need a higher class, while quick surveys can use a general class. State the required class in the specification.
Related models