Karl Fischer Moisture Analyzer for Solids and Liquids
固体液体卡尔费休水分分析仪
- SKU KFT-0005
- Karl Fischer Titrators
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measuring range | 1 µg to 100 mg water |
|---|---|
| Modes | Volumetric and coulometric |
| Liquid injection | Septum port or autosampler |
| Solid handling | Oven or headspace accessory |
| Oven temperature range | 40–250 °C |
| Sample positions | up to 20–40 vials |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <921>, Ph. Eur. 2.5.12, JP 2.48
What is the Karl Fischer Moisture Analyzer for Solids and Liquids?
A Karl Fischer moisture analyzer measures water in both solids and liquids with automated sampling and reagent handling. It is chosen for busy laboratories with mixed sample types and higher routine throughput requirements.
What is the Karl Fischer Moisture Analyzer for Solids and Liquids?
A Karl Fischer moisture analyzer measures water in both solids and liquids with automated sampling and reagent handling. It is chosen for busy laboratories with mixed sample types and higher routine throughput requirements.
Overview
Many quality control laboratories handle a mixture of powders, granules, oils and solutions, and a moisture analyzer that accommodates several sample types reduces instrument count and method switching. Such systems usually combine volumetric and coulometric modes, offer direct injection for liquids and an oven or headspace accessory for solids, and automate routine tasks such as drift determination, solvent exchange, standard addition and report generation. Autosamplers allow a series of samples to be processed unattended, with each result linked to its sample identity. The key selection questions are whether both modes are needed, how solids are handled, and how much automation is worthwhile. Accuracy still depends on careful sample handling, dry reagents and a properly sealed cell.
How does it work?
The Karl Fischer method reacts water stoichiometrically with iodine, sulfur dioxide and an alcohol, usually methanol, to form hydrogen iodide and a sulfate ester. The amount of water is therefore proportional to the iodine consumed. In volumetric titration a reagent containing iodine is added from a burette until all water has reacted, and the endpoint is detected by a platinum electrode pair as a rise in conductivity or a drop in potential once free iodine appears. In coulometric titration iodine is generated electrochemically at the anode, and the charge required gives the water content directly by Faraday's law, which suits very low water levels. Anhydrous conditions, dry reagents and a sealed titration cell are essential, since atmospheric moisture is the main source of error.
What are the key features?
- Volumetric and coulometric modes in one system
- Direct injection for liquid samples
- Oven or headspace accessory for solids
- Automated drift determination and solvent exchange
- Autosampler linked to sample identity
- Automatic report generation
What are the technical specifications?
A typical karl fischer moisture analyzer for solids and liquids configuration offers measuring range of 1 µg to 100 mg water, modes of Volumetric and coulometric, liquid injection of Septum port or autosampler, solid handling of Oven or headspace accessory, oven temperature range of 40–250 °C and sample positions of up to 20–40 vials. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Karl Fischer Moisture Analyzer for Solids and Liquids is used in mixed solid and liquid sample testing, multi-product quality control, high-throughput moisture testing and method development across sample types. Across the wider Karl Fischer Titrators class, laboratories also deploy it for water content of drug substances, excipient moisture testing and lyophilised product water content.
Which standards and certifications apply?
Relevant standards and methods include USP <921>, Ph. Eur. 2.5.12, JP 2.48, ICH Q2(R2), IEC 61010-1 and ISO 17025. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Work with dry glassware and fresh reagents, and keep the titration cell sealed when not in use, because the drift rate caused by atmospheric moisture is the main indicator of system condition. Perform a drift determination before starting, and replace solvent and reagent when drift rises. Calibrate the titrant against a certified water standard such as sodium tartrate or a water-in-methanol standard, and verify with an independent standard at defined intervals. Check sealing, electrodes and drying tubes, and record drift, standardisation and results. For oven methods, verify the temperature programme and the transfer line, since incomplete release or condensation causes low and variable results.
How do I select the right Karl Fischer Moisture Analyzer for Solids and Liquids?
Choose a combined moisture analyzer when sample types vary and throughput is significant. Confirm both titration modes, the solid-handling accessory, autosampler capacity and software for methods and audit trails. Decide how much automation is justified by your sample numbers and staffing.
How does it compare with other Karl Fischer Titrators variants?
Choose the technique by expected water content. Volumetric titration suits water contents from about 0.1 to 100 percent and is faster for samples with appreciable water. Coulometric titration suits very low water levels, down to micrograms of water, and is preferred for lyophilised products and anhydrous solvents. Combined instruments switch between modes. For solids that do not dissolve or react with the reagent, an oven sample changer or a headspace method releases water by heating and carries it into the cell with a dry gas, which avoids side reactions and contamination. Compare measuring range, resolution, endpoint detection, titration cell sealing, sample changer capacity and software with audit trails.
Full specifications
| Measuring range | 1 µg to 100 mg water |
|---|---|
| Modes | Volumetric and coulometric |
| Liquid injection | Septum port or autosampler |
| Solid handling | Oven or headspace accessory |
| Oven temperature range | 40–250 °C |
| Sample positions | up to 20–40 vials |
| Software | Methods, calculations, audit trail |
| Power supply | 220 V, 50 Hz, about 0.5 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Mixed solid and liquid sample testing
- Multi-product quality control
- High-throughput moisture testing
- Method development across sample types
Key features
- Volumetric and coulometric modes in one system
- Direct injection for liquid samples
- Oven or headspace accessory for solids
- Automated drift determination and solvent exchange
- Autosampler linked to sample identity
- Automatic report generation
Frequently asked questions about Karl Fischer Moisture Analyzer for Solids and Liquids
Usually yes, with the appropriate accessories: direct injection for liquids and oils, and an oven or headspace module for powders and solids. Each sample type needs its own validated method, including solvent and release conditions.
When many samples are tested daily and results must be traceable, yes. Autosamplers, automatic drift determination and report generation reduce operator time and transcription errors, which offsets the higher purchase price over the instrument's life.
Selecting and validating methods for each matrix, deciding sample size, recognising an abnormal drift or slow endpoint, and interpreting results against specification. Automation reduces routine work but not the need for trained analytical judgement.
It is a specific titrimetric method that determines water content from the stoichiometric reaction of water with iodine, sulfur dioxide and an alcohol. It measures water directly and is therefore suitable for water content limits in pharmacopoeial monographs.
Use volumetric for water contents from about 0.1 to 100 percent, where a burette delivers iodine reagent. Use coulometric for very low water levels, typically micrograms to a few milligrams of water per sample, where iodine is generated electrochemically.
Drift is the rate at which the cell gains water from the atmosphere or from reaction with residual moisture, and it is subtracted from the titration result. High or rising drift indicates a sealing problem, wet reagent or contaminated solvent, and causes inaccurate low results.
Related models