Karl Fischer Titrator with Oven Sample Changer
配烘箱进样器的卡尔费休滴定仪
- SKU KFT-0004
- Karl Fischer Titrators
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Oven temperature range | 40–300 °C |
|---|---|
| Temperature accuracy | about ±1 °C |
| Sample positions | up to 20–40 vials |
| Carrier gas flow | about 20–80 mL/min |
| Titration mode | Volumetric or coulometric |
| Heating time | programmable, 1–30 min |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <921>, Ph. Eur. 2.5.12, JP 2.48
What is the Karl Fischer Titrator with Oven Sample Changer?
A Karl Fischer titrator with an oven sample changer heats samples to release water and carries it into the titration cell with dry gas. It is chosen for solids that do not dissolve or that react with the reagent.
What is the Karl Fischer Titrator with Oven Sample Changer?
A Karl Fischer titrator with an oven sample changer heats samples to release water and carries it into the titration cell with dry gas. It is chosen for solids that do not dissolve or that react with the reagent.
Overview
Some solids dissolve poorly in Karl Fischer solvent, and some react with methanol or iodine to give side reactions. The oven method avoids both problems: the sample is sealed in a vial, heated to a defined temperature in a sample changer, and the released water is transferred into the titration cell by a stream of dry carrier gas. Because only water enters the cell, contamination and side reactions are minimised and the cell needs less solvent maintenance. The instrument programs a temperature profile and a carrier gas flow, and the sample changer processes a series of vials automatically. Correct release temperature and time must be established for each matrix, because too low a temperature leaves water in the sample and too high a temperature can decompose it and release water artificially.
How does it work?
The Karl Fischer method reacts water stoichiometrically with iodine, sulfur dioxide and an alcohol, usually methanol, to form hydrogen iodide and a sulfate ester. The amount of water is therefore proportional to the iodine consumed. In volumetric titration a reagent containing iodine is added from a burette until all water has reacted, and the endpoint is detected by a platinum electrode pair as a rise in conductivity or a drop in potential once free iodine appears. In coulometric titration iodine is generated electrochemically at the anode, and the charge required gives the water content directly by Faraday's law, which suits very low water levels. Anhydrous conditions, dry reagents and a sealed titration cell are essential, since atmospheric moisture is the main source of error.
What are the key features?
- Vial heating with a programmable temperature profile
- Dry carrier gas transfer of released water
- Automatic processing of a vial series
- Reduced side reactions with the reagent
- Lower solvent consumption in the cell
- Release temperature validated per matrix
What are the technical specifications?
A typical karl fischer titrator with oven sample changer configuration offers oven temperature range of 40–300 °C, temperature accuracy of about ±1 °C, sample positions of up to 20–40 vials, carrier gas flow of about 20–80 mL/min, titration mode of Volumetric or coulometric and heating time of programmable, 1–30 min. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Karl Fischer Titrator with Oven Sample Changer is used in water in insoluble powders, moisture in plastics and packaging, water in lyophilised cakes and samples reacting with the reagent. Across the wider Karl Fischer Titrators class, laboratories also deploy it for water content of drug substances, excipient moisture testing and lyophilised product water content.
Which standards and certifications apply?
Relevant standards and methods include USP <921>, Ph. Eur. 2.5.12, JP 2.48, ICH Q2(R2), IEC 61010-1 and ISO 17025. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Work with dry glassware and fresh reagents, and keep the titration cell sealed when not in use, because the drift rate caused by atmospheric moisture is the main indicator of system condition. Perform a drift determination before starting, and replace solvent and reagent when drift rises. Calibrate the titrant against a certified water standard such as sodium tartrate or a water-in-methanol standard, and verify with an independent standard at defined intervals. Check sealing, electrodes and drying tubes, and record drift, standardisation and results. For oven methods, verify the temperature programme and the transfer line, since incomplete release or condensation causes low and variable results.
How do I select the right Karl Fischer Titrator with Oven Sample Changer?
Specify an oven sample changer when samples do not dissolve in Karl Fischer solvent or cause side reactions, and when many vials must be processed automatically. Confirm temperature range and accuracy, carrier gas control, vial capacity and heated transfer line. Validate the release temperature for each matrix.
How does it compare with other Karl Fischer Titrators variants?
Choose the technique by expected water content. Volumetric titration suits water contents from about 0.1 to 100 percent and is faster for samples with appreciable water. Coulometric titration suits very low water levels, down to micrograms of water, and is preferred for lyophilised products and anhydrous solvents. Combined instruments switch between modes. For solids that do not dissolve or react with the reagent, an oven sample changer or a headspace method releases water by heating and carries it into the cell with a dry gas, which avoids side reactions and contamination. Compare measuring range, resolution, endpoint detection, titration cell sealing, sample changer capacity and software with audit trails.
Full specifications
| Oven temperature range | 40–300 °C |
|---|---|
| Temperature accuracy | about ±1 °C |
| Sample positions | up to 20–40 vials |
| Carrier gas flow | about 20–80 mL/min |
| Titration mode | Volumetric or coulometric |
| Heating time | programmable, 1–30 min |
| Transfer line | Heated to prevent condensation |
| Power supply | 220 V, 50 Hz, about 0.5 kW |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Water in insoluble powders
- Moisture in plastics and packaging
- Water in lyophilised cakes
- Samples reacting with the reagent
Key features
- Vial heating with a programmable temperature profile
- Dry carrier gas transfer of released water
- Automatic processing of a vial series
- Reduced side reactions with the reagent
- Lower solvent consumption in the cell
- Release temperature validated per matrix
Frequently asked questions about Karl Fischer Titrator with Oven Sample Changer
By running a temperature ramp with a standard or a representative sample and finding the point where all water is released without decomposition. Too low a temperature under-reports water, while too high a temperature can degrade the sample and release water that was not free.
To prevent water vapour from condensing before it reaches the titration cell. Condensation would retain water in the tubing and give low, variable results, especially at high oven temperatures and low carrier gas flows.
Usually yes, because only water and dry gas enter the cell, so the solvent stays cleaner longer and needs less frequent replacement. This reduces solvent consumption and operator exposure, which is a practical benefit of the method.
It is a specific titrimetric method that determines water content from the stoichiometric reaction of water with iodine, sulfur dioxide and an alcohol. It measures water directly and is therefore suitable for water content limits in pharmacopoeial monographs.
Use volumetric for water contents from about 0.1 to 100 percent, where a burette delivers iodine reagent. Use coulometric for very low water levels, typically micrograms to a few milligrams of water per sample, where iodine is generated electrochemically.
Drift is the rate at which the cell gains water from the atmosphere or from reaction with residual moisture, and it is subtracted from the titration result. High or rising drift indicates a sealing problem, wet reagent or contaminated solvent, and causes inaccurate low results.