Skip to main content
Lab Manufacturers China
Volumetric-Coulometric Karl Fischer Titrator — product photo

Volumetric-Coulometric Karl Fischer Titrator

容量-库仑复合卡尔费休滴定仪

  • SKU KFT-0003
  • Karl Fischer Titrators
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Volumetric range100 ppm to 100 percent water
Coulometric range1 µg to 100 mg water
Burette volume10–25 mL
Generation currentup to 400 mA
Endpoint detectionBipotentiometric platinum electrode
Stored methodsMultiple per mode
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <921>, Ph. Eur. 2.5.12, JP 2.48

What is the Volumetric-Coulometric Karl Fischer Titrator?

A volumetric-coulometric titrator combines both titration modes in one instrument and switches between them as water content requires. It is chosen by laboratories that test samples spanning high and very low moisture levels.

What is the Volumetric-Coulometric Karl Fischer Titrator?

A volumetric-coulometric titrator combines both titration modes in one instrument and switches between them as water content requires. It is chosen by laboratories that test samples spanning high and very low moisture levels.

Overview

A combined titrator houses both a burette for volumetric titration and a coulometric cell with a generator electrode, so a laboratory can measure high-moisture samples such as granules and very dry samples such as lyophilised cakes without keeping two instruments. Changeover is usually straightforward, with a dedicated cell for each mode and stored methods that recall the correct parameters, standards and calculations. The software manages drift determination, standardisation for volumetric mode and generation current for coulometric mode, and reports results in the units required by the monograph. The main advantage is flexibility and bench economy; the main caution is that the coulometric cell must be kept scrupulously dry and free of residues from previous samples, so cleaning between modes is important.

How does it work?

The Karl Fischer method reacts water stoichiometrically with iodine, sulfur dioxide and an alcohol, usually methanol, to form hydrogen iodide and a sulfate ester. The amount of water is therefore proportional to the iodine consumed. In volumetric titration a reagent containing iodine is added from a burette until all water has reacted, and the endpoint is detected by a platinum electrode pair as a rise in conductivity or a drop in potential once free iodine appears. In coulometric titration iodine is generated electrochemically at the anode, and the charge required gives the water content directly by Faraday's law, which suits very low water levels. Anhydrous conditions, dry reagents and a sealed titration cell are essential, since atmospheric moisture is the main source of error.

What are the key features?

  • Burette and coulometric cell in one instrument
  • Switch between modes as required
  • Stored methods per mode with parameters
  • Drift determination and standardisation support
  • Results in monograph-required units
  • Dedicated cells with cleaning between modes

What are the technical specifications?

A typical volumetric-coulometric karl fischer titrator configuration offers volumetric range of 100 ppm to 100 percent water, coulometric range of 1 µg to 100 mg water, burette volume of 10–25 mL, generation current of up to 400 mA, endpoint detection of Bipotentiometric platinum electrode and stored methods of Multiple per mode. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Volumetric-Coulometric Karl Fischer Titrator is used in mixed moisture-level sample testing, lyophilised and granule products, multi-product quality control and method development across ranges. Across the wider Karl Fischer Titrators class, laboratories also deploy it for water content of drug substances, excipient moisture testing and lyophilised product water content.

Which standards and certifications apply?

Relevant standards and methods include USP <921>, Ph. Eur. 2.5.12, JP 2.48, ICH Q2(R2), IEC 61010-1 and ISO 17025. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Work with dry glassware and fresh reagents, and keep the titration cell sealed when not in use, because the drift rate caused by atmospheric moisture is the main indicator of system condition. Perform a drift determination before starting, and replace solvent and reagent when drift rises. Calibrate the titrant against a certified water standard such as sodium tartrate or a water-in-methanol standard, and verify with an independent standard at defined intervals. Check sealing, electrodes and drying tubes, and record drift, standardisation and results. For oven methods, verify the temperature programme and the transfer line, since incomplete release or condensation causes low and variable results.

How do I select the right Volumetric-Coulometric Karl Fischer Titrator?

Choose a combined instrument when the laboratory tests both high- and low-moisture samples, or to avoid the cost and bench space of two systems. Confirm that both modes meet the required ranges and precision, that methods and standards are stored per mode, and that switching and cleaning are practical for routine use.

How does it compare with other Karl Fischer Titrators variants?

Choose the technique by expected water content. Volumetric titration suits water contents from about 0.1 to 100 percent and is faster for samples with appreciable water. Coulometric titration suits very low water levels, down to micrograms of water, and is preferred for lyophilised products and anhydrous solvents. Combined instruments switch between modes. For solids that do not dissolve or react with the reagent, an oven sample changer or a headspace method releases water by heating and carries it into the cell with a dry gas, which avoids side reactions and contamination. Compare measuring range, resolution, endpoint detection, titration cell sealing, sample changer capacity and software with audit trails.

Full specifications

Full specifications
Volumetric range100 ppm to 100 percent water
Coulometric range1 µg to 100 mg water
Burette volume10–25 mL
Generation currentup to 400 mA
Endpoint detectionBipotentiometric platinum electrode
Stored methodsMultiple per mode
SoftwareDrift, standardisation, audit trail
Power supply220 V, 50 Hz, about 0.15 kW

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Mixed moisture-level sample testing
  • Lyophilised and granule products
  • Multi-product quality control
  • Method development across ranges

Key features

  • Burette and coulometric cell in one instrument
  • Switch between modes as required
  • Stored methods per mode with parameters
  • Drift determination and standardisation support
  • Results in monograph-required units
  • Dedicated cells with cleaning between modes

Frequently asked questions about Volumetric-Coulometric Karl Fischer Titrator

For most pharmaceutical work yes, provided each mode is validated for its range and the coulometric cell is kept very dry. Laboratories with extremely demanding low-level work may still prefer a dedicated coulometric instrument for stability.

Request a quotation for the Volumetric-Coulometric Karl Fischer Titrator

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote