Skip to main content
Lab Manufacturers China
Coulometric Karl Fischer Titrator — product photo

Coulometric Karl Fischer Titrator

库仑法卡尔费休滴定仪

  • SKU KFT-0002
  • Karl Fischer Titrators
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Measuring range1 µg to 100 mg water
Limit of detectionabout 1 µg water
Generation currentup to 400 mA
Endpoint detectionBipotentiometric platinum electrode
Precisionabout 1–2 percent RSD
Cell designDiaphragm or diaphragm-free
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <921>, Ph. Eur. 2.5.12, JP 2.48

What is the Coulometric Karl Fischer Titrator?

A coulometric Karl Fischer titrator generates iodine electrochemically and determines very low water levels from the charge consumed. It is chosen for lyophilised products, anhydrous solvents and other samples with microgram water content.

What is the Coulometric Karl Fischer Titrator?

A coulometric Karl Fischer titrator generates iodine electrochemically and determines very low water levels from the charge consumed. It is chosen for lyophilised products, anhydrous solvents and other samples with microgram water content.

Overview

In coulometric Karl Fischer titration the sample is added to an anhydrous anolyte in a sealed cell, and iodine is generated at the anode by passing current. Water reacts immediately with the generated iodine, and the titration ends when free iodine is detected, so the total charge consumed is proportional to the water present by Faraday's law. Because no titrant is added from a burette, the technique is very sensitive and can determine micrograms of water, which suits lyophilised products, anhydrous solvents, oils and low-moisture powders. The cell has separate anodic and cathodic compartments to prevent reduced species from interfering, and drift must be measured and subtracted. Sample size is small, so homogeneity and weighing accuracy are important.

How does it work?

The Karl Fischer method reacts water stoichiometrically with iodine, sulfur dioxide and an alcohol, usually methanol, to form hydrogen iodide and a sulfate ester. The amount of water is therefore proportional to the iodine consumed. In volumetric titration a reagent containing iodine is added from a burette until all water has reacted, and the endpoint is detected by a platinum electrode pair as a rise in conductivity or a drop in potential once free iodine appears. In coulometric titration iodine is generated electrochemically at the anode, and the charge required gives the water content directly by Faraday's law, which suits very low water levels. Anhydrous conditions, dry reagents and a sealed titration cell are essential, since atmospheric moisture is the main source of error.

What are the key features?

  • Electrochemical iodine generation at the anode
  • Detection of microgram water levels
  • Separate anodic and cathodic compartments
  • Automatic drift compensation
  • Small sample size with accurate weighing
  • Suited to lyophilised and anhydrous products

What are the technical specifications?

A typical coulometric karl fischer titrator configuration offers measuring range of 1 µg to 100 mg water, limit of detection of about 1 µg water, generation current of up to 400 mA, endpoint detection of Bipotentiometric platinum electrode, precision of about 1–2 percent RSD and cell design of Diaphragm or diaphragm-free. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Coulometric Karl Fischer Titrator is used in lyophilised product water content, anhydrous solvent testing, oil and lipid moisture and low-moisture powder testing. Across the wider Karl Fischer Titrators class, laboratories also deploy it for water content of drug substances, excipient moisture testing and lyophilised product water content.

Which standards and certifications apply?

Relevant standards and methods include USP <921>, Ph. Eur. 2.5.12, JP 2.48, ICH Q2(R2), IEC 61010-1 and ISO 17025. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Work with dry glassware and fresh reagents, and keep the titration cell sealed when not in use, because the drift rate caused by atmospheric moisture is the main indicator of system condition. Perform a drift determination before starting, and replace solvent and reagent when drift rises. Calibrate the titrant against a certified water standard such as sodium tartrate or a water-in-methanol standard, and verify with an independent standard at defined intervals. Check sealing, electrodes and drying tubes, and record drift, standardisation and results. For oven methods, verify the temperature programme and the transfer line, since incomplete release or condensation causes low and variable results.

How do I select the right Coulometric Karl Fischer Titrator?

Choose coulometric titration for water contents below about 0.1 percent or when sample quantity is limited. Confirm measuring range, generation current, cell design and drift compensation. Weigh samples accurately and control sampling time, because atmospheric moisture uptake during handling is significant at these levels.

How does it compare with other Karl Fischer Titrators variants?

Choose the technique by expected water content. Volumetric titration suits water contents from about 0.1 to 100 percent and is faster for samples with appreciable water. Coulometric titration suits very low water levels, down to micrograms of water, and is preferred for lyophilised products and anhydrous solvents. Combined instruments switch between modes. For solids that do not dissolve or react with the reagent, an oven sample changer or a headspace method releases water by heating and carries it into the cell with a dry gas, which avoids side reactions and contamination. Compare measuring range, resolution, endpoint detection, titration cell sealing, sample changer capacity and software with audit trails.

Full specifications

Full specifications
Measuring range1 µg to 100 mg water
Limit of detectionabout 1 µg water
Generation currentup to 400 mA
Endpoint detectionBipotentiometric platinum electrode
Precisionabout 1–2 percent RSD
Cell designDiaphragm or diaphragm-free
Drift compensationAutomatic
Power supply220 V, 50 Hz, about 0.1 kW

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Lyophilised product water content
  • Anhydrous solvent testing
  • Oil and lipid moisture
  • Low-moisture powder testing

Key features

  • Electrochemical iodine generation at the anode
  • Detection of microgram water levels
  • Separate anodic and cathodic compartments
  • Automatic drift compensation
  • Small sample size with accurate weighing
  • Suited to lyophilised and anhydrous products

Frequently asked questions about Coulometric Karl Fischer Titrator

It can determine around one microgram of water, equivalent to a few parts per million in a one gram sample. This sensitivity suits lyophilised products and anhydrous solvents where volumetric titration would be too insensitive.

Request a quotation for the Coulometric Karl Fischer Titrator

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote