Electrothermal Vaporization Sample Introduction System
电热蒸发样品引入系统
- SKU ISI-0004
- ICP Sample Introduction Systems
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- Elemental cleanliness test (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Sample volume | 5–50 µL |
|---|---|
| Solid sample mass | 0.1–10 mg |
| Vaporizer | graphite or metal filament |
| Maximum temperature | up to 2600 °C |
| Transport gas | argon, 0.5–1.5 L/min |
| Temperature steps | up to 10 |
By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <730> Plasma Spectrochemistry, ISO 11885 Water quality — ICP-OES determination of elements, US EPA Method 200.7
What is the Electrothermal Vaporization Sample Introduction System?
An electrothermal vaporization sample introduction system heats microlitre or milligram samples to form a vapor for the plasma. It is chosen for small-volume samples and for matrices that are difficult to nebulize.
What is the Electrothermal Vaporization Sample Introduction System?
An electrothermal vaporization sample introduction system heats microlitre or milligram samples to form a vapor for the plasma. It is chosen for small-volume samples and for matrices that are difficult to nebulize.
Overview
The sample is placed on a graphite or metal filament, boat or crucible, then heated in programmed stages to dry it, remove matrix and finally vaporize the analytes. The vapor is carried by argon into the plasma. Because the sample is vaporized rather than nebulized, transport efficiency is high and sample requirements are small, typically 5 to 50 microlitres or a few milligrams. Matrix removal during the pyrolysis stage reduces oxide and chloride interferences, and the technique handles slurries and some solid samples. Throughput is lower than nebulization because each sample needs a full heating cycle, and temperature programs must be developed per matrix. It is used for micro-samples, refractory materials, and analyses where sample quantity is limited.
How does it work?
The sample introduction system determines how much sample reaches the plasma and in what form. For liquids, a peristaltic pump delivers sample to a nebulizer, which creates an aerosol; a spray chamber then removes large droplets so only fine droplets enter the plasma. Nebulizer type and spray chamber design set transport efficiency, which is typically only a few percent, and thus sensitivity. Ultrasonic nebulizers use vibration to produce finer aerosols and improve transport, while electrothermal vaporization heats a small sample to form a vapor. Hydride generation converts certain elements into volatile species, separating them from the matrix. Laser ablation removes solid particles from a sample surface for direct analysis. Whichever approach is used, transport tubing length and gas flows must be optimized, and washout between samples controls carry-over.
What are the key features?
- Graphite or metal filament and boat vaporizer
- Programmed drying, pyrolysis and vaporization
- Small sample volumes from 5 to 50 µL
- High transport efficiency with dry vapor
- Handles slurries and some solid samples
- Matrix removal reduces interferences
What are the technical specifications?
A typical electrothermal vaporization sample introduction system configuration offers sample volume of 5–50 µL, solid sample mass of 0.1–10 mg, vaporizer of graphite or metal filament, maximum temperature of up to 2600 °C, transport gas of argon, 0.5–1.5 L/min and temperature steps of up to 10. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Electrothermal Vaporization Sample Introduction System is used in micro-volume biological and clinical samples, refractory and ceramic material analysis, slurry sampling of powders and trace analysis where sample quantity is limited. Across the wider ICP Sample Introduction Systems class, laboratories also deploy it for routine liquid sample delivery for ICP-OES and ICP-MS, trace analysis with improved transport efficiency and direct solid sampling and elemental mapping.
Which standards and certifications apply?
Relevant standards and methods include USP <730> Plasma Spectrochemistry, ISO 11885 Water quality — ICP-OES determination of elements, US EPA Method 200.7, US EPA Method 200.8, US EPA Method 6020B and ISO/IEC 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and Elemental cleanliness test; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Sample introduction components are the most frequently replaced parts of an ICP system and are the usual cause of reduced sensitivity or precision. Nebulizers clog, corrode or crack; spray chambers accumulate deposits; pump tubing stretches and changes flow; and laser cells and transport lines adsorb analytes. Establish cleaning and replacement schedules and keep spares. Transport efficiency depends on gas flow, tubing length and chamber design, so changing one component may require method reoptimization. For high-solids samples, dilute or use a matrix-tolerant nebulizer to avoid blockages. Always check uptake rate and aerosol quality after maintenance, and verify performance with a check standard before releasing results.
How do I select the right Electrothermal Vaporization Sample Introduction System?
Select electrothermal vaporization when sample volume is very small, when slurries or refractory materials cannot be nebulized, or when matrix removal is needed before the plasma. Specify the sample type, volume and analytes. Plan method development for temperature programs, and accept lower throughput than liquid nebulization.
How does it compare with other ICP Sample Introduction Systems variants?
Select a sample introduction system by sample type, detection limit requirements and matrix. A concentric nebulizer with a cyclonic spray chamber is the standard, efficient choice for clean aqueous solutions. High dissolved solids need a V-groove, cross-flow or high-solids nebulizer that resists blockage. Ultrasonic nebulization improves detection limits for trace work when sample volume allows. Laser ablation is chosen for solid samples and spatial mapping, and electrothermal vaporization for very small volumes or micro-samples. Hydride generation targets arsenic, selenium and related elements with matrix separation. Autosamplers with peristaltic pumps provide reproducible delivery and throughput. Confirm compatibility with your torch, plasma gas flows and instrument software.
Full specifications
| Sample volume | 5–50 µL |
|---|---|
| Solid sample mass | 0.1–10 mg |
| Vaporizer | graphite or metal filament |
| Maximum temperature | up to 2600 °C |
| Transport gas | argon, 0.5–1.5 L/min |
| Temperature steps | up to 10 |
| Detection limit | 0.01–1 µg/L equivalent |
| Throughput | 10–30 samples/h |
| Cycle time | 60–180 s per sample |
| Coupling | ICP-OES or ICP-MS |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Micro-volume biological and clinical samples
- Refractory and ceramic material analysis
- Slurry sampling of powders
- Trace analysis where sample quantity is limited
Key features
- Graphite or metal filament and boat vaporizer
- Programmed drying, pyrolysis and vaporization
- Small sample volumes from 5 to 50 µL
- High transport efficiency with dry vapor
- Handles slurries and some solid samples
- Matrix removal reduces interferences
Frequently asked questions about Electrothermal Vaporization Sample Introduction System
During pyrolysis the sample is heated enough to remove solvent and matrix but not the analyte. This reduces the amount of matrix entering the plasma, lowering oxide, chloride and carbon interferences and improving detection limits. The pyrolysis temperature is chosen so the analyte is retained.
Yes, small solid pieces or slurries can be placed on the vaporizer and heated, which avoids digestion for some materials. Homogeneity, weighing and matrix variation then limit accuracy, so replicates and matrix-matched standards are used. Slurry methods require stable, fine suspensions.
Each sample requires drying, pyrolysis, vaporization and cleaning stages in the furnace, so a full cycle takes one to three minutes. Nebulization measures continuously, so many samples can be run in the same time. Electrothermal vaporization is chosen for sample-limited or matrix-difficult cases, not for high throughput.
A pneumatic nebulizer produces droplets of many sizes, and the spray chamber removes most of them to prevent solvent overload and plasma instability. Only a few percent of the sample reaches the plasma. This is why nebulizer and spray chamber design, and the resulting fine aerosol fraction, strongly affect sensitivity.
V-groove, cross-flow, Babington or parallel-path nebulizers tolerate high salt content better than concentric designs because they have wider orifices and resist blockage. A heated spray chamber and dilution also help. Dedicated high-solids kits reduce maintenance and improve long-term stability.
Ultrasonic nebulization produces a finer aerosol and improves transport efficiency, lowering detection limits by roughly five to ten times for clean samples. It uses more sample volume and needs desolvation, and it is more affected by high dissolved solids, so it suits trace analysis of relatively clean solutions.