Electrochemiluminescence Immunoassay Analyzer
电化学发光免疫分析仪
- SKU IMM-0002
- Immunodiagnostics
- CE (to be confirmed)
- ISO 13485 quality system (to be confirmed)
- NMPA registration (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Throughput | 80–300 tests/h |
|---|---|
| Assay time | 9–18 min |
| Sample volume | 10–50 µL |
| Detection method | Ruthenium electrochemiluminescence |
| Reagent positions | 18–25 packs, cooled to 2–8 °C |
| Sample capacity | 50–150 tubes |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, IEC 61010-2-101, ISO 18113-1
What is the Electrochemiluminescence Immunoassay Analyzer?
An electrochemiluminescence immunoassay analyzer generates light from ruthenium-labeled complexes at an electrode surface, allowing very sensitive measurement of hormones, tumor markers, cardiac markers and infectious disease markers. It is selected by laboratories requiring wide dynamic range and small sample volumes.
What is the Electrochemiluminescence Immunoassay Analyzer?
An electrochemiluminescence immunoassay analyzer generates light from ruthenium-labeled complexes at an electrode surface, allowing very sensitive measurement of hormones, tumor markers, cardiac markers and infectious disease markers. It is selected by laboratories requiring wide dynamic range and small sample volumes.
Overview
In this variant, streptavidin-coated magnetic microparticles capture biotinylated antibody complexes labeled with a ruthenium chelate. The mixture is drawn into a flow cell where magnets hold the beads on an electrode and a voltage triggers an electrochemical reaction with tripropylamine, producing repeated light emission from each label. A photomultiplier measures the signal, which offers dynamic range of about six orders of magnitude. Typical assay times are 9 to 18 minutes, with throughput of 80 to 300 tests per hour. Sample volumes are as low as 10 to 50 microliters. The design uses closed reagent packs with barcodes, which reduces operator steps. Laboratories should be aware of biotin interference in streptavidin-based formats and review manufacturer mitigation and flagging.
How does it work?
Immunodiagnostic platforms exploit the specific binding of an antibody to its antigen. In a sandwich assay, a capture antibody on a solid phase such as a magnetic microparticle or microplate binds the analyte, and a labeled detection antibody forms a complex whose signal is proportional to concentration. In competitive assays, labeled and sample antigens compete for limited antibody sites and signal falls as concentration rises. Labels include enzymes such as horseradish peroxidase or alkaline phosphatase, acridinium esters or ruthenium complexes for luminescence, and lanthanide chelates or fluorophores. After incubation and washing to remove unbound label, a photomultiplier, fluorometer or photometer measures the signal, and a calibration curve converts it to concentration. Automation handles pipetting, incubation, washing and result calculation.
What are the key features?
- Ruthenium-label electrochemiluminescence detection in a flow cell
- Streptavidin magnetic microparticle capture with barcoded reagent packs
- Assay times of 9–18 minutes for rapid turnaround
- Dynamic range of about six orders of magnitude
- Small sample volume of 10–50 µL per test
- Random access with STAT priority and onboard calibration management
What are the technical specifications?
A typical electrochemiluminescence immunoassay analyzer configuration offers throughput of 80–300 tests/h, assay time of 9–18 min, sample volume of 10–50 µL, detection method of Ruthenium electrochemiluminescence, reagent positions of 18–25 packs, cooled to 2–8 °C and sample capacity of 50–150 tubes. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Electrochemiluminescence Immunoassay Analyzer is used in cardiac troponin and NT-proBNP, tumor marker panels, fertility and thyroid hormones and infectious disease serology. Across the wider Immunodiagnostics class, laboratories also deploy it for infectious disease serology screening, thyroid and reproductive hormone testing and tumor marker monitoring.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, IEC 61010-2-101, ISO 18113-1, CLSI EP05, CLSI EP07, CLSI EP17, CLSI I/LA23 and ISO 13485. Certification candidates for this model are CE, ISO 13485 quality system and NMPA registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place analyzers on a stable bench with temperature and humidity within the stated range, away from direct sunlight, and provide purified water, waste drainage and stable power where required. Follow maintenance schedules for washing systems, probes and optics, and run daily controls at several levels. Verify new lots and calibration according to laboratory procedures, and monitor for interferences such as biotin, heterophilic antibodies or the hook effect. Store reagents at 2–8 °C and observe onboard stability. Handle specimens as potentially infectious, dispose of liquid waste according to biosafety rules, and document maintenance, calibration and operator competence under ISO 15189. Plan service coverage and reagent logistics for the market.
How do I select the right Electrochemiluminescence Immunoassay Analyzer?
Choose electrochemiluminescence when rapid turnaround, low sample volume and wide dynamic range are priorities. Specify menu, expected daily tests, STAT needs, reagent policy, water supply, LIS protocol and biotin interference handling in the RFQ, and request supporting performance data.
How does it compare with other Immunodiagnostics variants?
Match the platform to menu and volume. Chemiluminescence and electrochemiluminescence systems offer wide dynamic range and high sensitivity for hormones, tumor markers and infectious disease serology at medium to high volume. Time-resolved fluorescence suits low-concentration analytes such as newborn screening and fertility hormones. Dry fluorescence readers with cartridges serve small laboratories and emergency testing for cardiac markers. ELISA remains flexible and economical for batch testing and blood screening. Compare reagent menu, closed or open status, onboard reagent stability, sample volume, calibration interval, throughput in tests per hour, and LIS connectivity. Confirm reagent registration in your market, supply reliability and cost per reportable result.
Full specifications
| Throughput | 80–300 tests/h |
|---|---|
| Assay time | 9–18 min |
| Sample volume | 10–50 µL |
| Detection method | Ruthenium electrochemiluminescence |
| Reagent positions | 18–25 packs, cooled to 2–8 °C |
| Sample capacity | 50–150 tubes |
| Dynamic range | ≈ 6 orders of magnitude |
| Precision (CV) | ≤ 5% (typical) |
| Reaction temperature | 37 ± 0.5 °C |
| Power supply | 220 V, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Cardiac troponin and NT-proBNP
- Tumor marker panels
- Fertility and thyroid hormones
- Infectious disease serology
Key features
- Ruthenium-label electrochemiluminescence detection in a flow cell
- Streptavidin magnetic microparticle capture with barcoded reagent packs
- Assay times of 9–18 minutes for rapid turnaround
- Dynamic range of about six orders of magnitude
- Small sample volume of 10–50 µL per test
- Random access with STAT priority and onboard calibration management
Frequently asked questions about Electrochemiluminescence Immunoassay Analyzer
Chemiluminescence emits light from a chemical reaction after adding a trigger, typically a single flash or glow, while electrochemiluminescence generates light at an electrode by applying a voltage, cycling the label repeatedly for signal amplification and tighter control of the reaction timing.
Most electrochemiluminescence platforms use closed, barcoded reagent packs designed for the instrument, which ensures validated performance but limits third-party reagent use. Buyers should confirm the available menu and the supply commitments for their region.
The measuring cell and electrode are cleaned automatically with system solutions during daily and weekly routines, and periodic manual maintenance covers probes, seals and tubing. Follow the manufacturer's schedule to keep background signal and precision within specification.
It is used to detect and quantify proteins, hormones, antibodies and antigens in blood and other specimens. Typical tests include hepatitis and HIV serology, thyroid and fertility hormones, tumor markers, cardiac troponin and allergy or autoimmune markers.
Both use antibody binding, but ELISA reads a colored enzyme product by absorbance, while CLIA reads emitted light, giving higher sensitivity and wider dynamic range. CLIA analyzers are usually fully automated with random access, whereas ELISA is often run in batches on microplates.
The hook effect is a falsely low result that occurs when an analyte concentration is so high that it saturates both capture and detection antibodies separately, preventing sandwich formation. Laboratories manage it by sample dilution or analyzers with antigen-excess checks, particularly for hCG, prolactin and tumor markers.