Digital PCR System
数字 PCR 系统
- SKU MOD-0003
- Molecular Diagnostics
- CE (to be confirmed)
- ISO 13485 quality system (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Partitions per reaction | 20,000–26,000 |
|---|---|
| Partition type | Droplets or nanowell chip |
| Fluorescence channels | 2–6 |
| Sample volume | 20–40 µL per reaction |
| Samples per run | 8–96 |
| Dynamic range | ≈ 1–100,000 copies/µL |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, IEC 61010-2-101, CLSI MM03
What is the Digital PCR System?
A digital PCR system partitions each reaction into thousands of droplets or microchambers and counts positive partitions to give absolute nucleic acid quantification without a standard curve. It is used for rare mutation detection, minimal residual disease, copy number analysis and reference material characterization.
What is the Digital PCR System?
A digital PCR system partitions each reaction into thousands of droplets or microchambers and counts positive partitions to give absolute nucleic acid quantification without a standard curve. It is used for rare mutation detection, minimal residual disease, copy number analysis and reference material characterization.
Overview
In droplet-based formats, a water-in-oil emulsion generator creates 20,000 or more droplets per sample, which are thermal cycled and then read individually by a droplet reader with two-color fluorescence. Chip-based systems use nanowell arrays with 20,000 or more fixed partitions. Poisson statistics convert the ratio of positive to total partitions into copies per microliter with confidence intervals. The method resolves variant allele fractions near 0.1 percent, is tolerant of PCR inhibitors and is used to calibrate standards for other assays. Workflow includes droplet generation, cycling on a standard thermal cycler and reading, taking 4 to 6 hours for 96 samples. Throughput and cost per sample are higher than real-time PCR, so dPCR is used when precision is essential.
How does it work?
Molecular diagnostics amplify a specific nucleic acid sequence so that it becomes detectable. In real-time PCR, thermal cycling denatures DNA, anneals primers and extends with a DNA polymerase, while fluorescent probes such as hydrolysis probes emit signal proportional to product accumulation, and the cycle threshold indicates starting quantity. RNA targets are first reverse-transcribed. Isothermal methods such as LAMP amplify at a constant temperature of about 60–65 °C. Digital PCR partitions a sample into thousands of droplets or wells and counts positive partitions for absolute quantification. Sequencing reads the order of bases by synthesis or nanopore detection. Controls such as internal controls and no-template controls verify extraction, amplification and contamination status in each run.
What are the key features?
- Partitioning into 20,000 or more droplets or nanowells per reaction
- Absolute quantification in copies per microliter without standards
- Detection of variant allele fractions near 0.1 percent
- Two-color fluorescence for duplex assays
- Tolerance to PCR inhibitors due to partitioning
- Software with Poisson correction and confidence intervals
What are the technical specifications?
A typical digital pcr system configuration offers partitions per reaction of 20,000–26,000, partition type of Droplets or nanowell chip, fluorescence channels of 2–6, sample volume of 20–40 µL per reaction, samples per run of 8–96 and dynamic range of ≈ 1–100,000 copies/µL. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Digital PCR System is used in rare mutation detection in oncology, minimal residual disease monitoring, copy number variation analysis, reference material value assignment and liquid biopsy research. Across the wider Molecular Diagnostics class, laboratories also deploy it for infectious disease PCR testing, oncology mutation testing and genetic and inherited disease testing.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, IEC 61010-2-101, CLSI MM03, CLSI MM06, CLSI EP17, ISO 20395, ISO 13485 and ISO 17822. Certification candidates for this model are CE, ISO 13485 quality system and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Molecular laboratories require unidirectional workflow with separate areas for reagent preparation, sample processing, amplification and post-amplification where applicable, or closed systems that reduce contamination risk. Use dedicated pipettes, filter tips, UV decontamination and routine surface cleaning. Calibrate thermal blocks and optical systems, and run positive, negative and internal controls in each run. Protect instruments from dust and vibration, use stable power, and follow reagent cold-chain requirements. Validate assays and instrument performance according to CLSI MM guidelines and laboratory procedures under ISO 15189. Manage biosafety for pathogen work and handle data with privacy controls, especially for genetic information.
How do I select the right Digital PCR System?
Select digital PCR when absolute quantification or detection of rare variants at about 0.1 percent is essential. Specify partition type, channel count, samples per run, workflow automation, assay availability, software validation and consumables cost per reaction in the RFQ.
How does it compare with other Molecular Diagnostics variants?
Choose by assay type, volume and laboratory skill level. Real-time PCR suits high-volume batch testing with open or closed assays. Sample-to-answer cartridge systems offer minimal hands-on time and fast results for low-volume or urgent testing. Digital PCR suits absolute quantification, rare variant detection and minimal residual disease. Isothermal analyzers fit decentralized settings with simple instrumentation. Sequencers suit broad genetic, oncology and pathogen genomics panels. Compare channels, throughput, sample volume, limit of detection, workflow steps, contamination control, and software for result interpretation. Verify assay availability and registration in your market, open channel versatility, LIS connectivity and service support, and plan laboratory zoning and staff training.
Full specifications
| Partitions per reaction | 20,000–26,000 |
|---|---|
| Partition type | Droplets or nanowell chip |
| Fluorescence channels | 2–6 |
| Sample volume | 20–40 µL per reaction |
| Samples per run | 8–96 |
| Dynamic range | ≈ 1–100,000 copies/µL |
| Rare variant sensitivity | ≈ 0.1% allele fraction |
| Precision | CV ≤ 5% above 1,000 copies |
| Workflow time | 4–6 h for 96 samples |
| Power supply | 100–240 V AC, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Rare mutation detection in oncology
- Minimal residual disease monitoring
- Copy number variation analysis
- Reference material value assignment
- Liquid biopsy research
Key features
- Partitioning into 20,000 or more droplets or nanowells per reaction
- Absolute quantification in copies per microliter without standards
- Detection of variant allele fractions near 0.1 percent
- Two-color fluorescence for duplex assays
- Tolerance to PCR inhibitors due to partitioning
- Software with Poisson correction and confidence intervals
Frequently asked questions about Digital PCR System
The sample is divided into many partitions so that each contains zero or a few target molecules. Counting positive and negative partitions and applying Poisson statistics gives concentration directly, independent of amplification efficiency or an external standard curve.
Digital PCR is preferred for rare variants, minimal residual disease, small fold changes in copy number and reference material quantification, where precision and absolute results matter. Real-time PCR remains more economical for routine screening and high-volume testing.
Droplet formats commonly generate droplets on one instrument, amplify in a standard thermal cycler and read on a droplet reader, while integrated chip systems combine partitioning, cycling and reading in one device. Confirm workflow and footprint before choosing.
It is the group of instruments that detect or quantify DNA and RNA in clinical specimens, typically by amplification such as PCR or by sequencing. Applications include infectious disease testing, oncology mutations, genetic disorders and viral load monitoring.
Real-time PCR estimates starting quantity from the cycle at which fluorescence crosses a threshold and needs a standard curve. Digital PCR partitions the sample and counts positive partitions for absolute quantification without a curve, which improves detection of rare variants.
Laboratories use separated pre- and post-amplification areas, unidirectional workflow, filter tips, UV decontamination and no-template controls. Closed cartridge systems and uracil-N-glycosylase in reagent mixes further reduce the risk of amplicon carryover.