Benchtop Next-Generation Sequencer for Clinical Use
临床用台式高通量测序仪
- SKU MOD-0005
- Molecular Diagnostics
- CE (to be confirmed)
- ISO 13485 quality system (to be confirmed)
- NMPA registration (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Output per run | 1–100 Gb |
|---|---|
| Read length | 75–300 bp (paired-end) |
| Run time | 12–48 h |
| Reads per run | 4–400 million |
| Base accuracy | ≥ 99.9% (Q30 ≥ 85%) |
| Sample multiplexing | Up to 96 or more index barcodes |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, IEC 61010-2-101, CLSI MM03
What is the Benchtop Next-Generation Sequencer for Clinical Use?
A benchtop next-generation sequencer for clinical use reads millions of DNA fragments in parallel to support gene panel testing, oncology profiling, inherited disease testing and pathogen genomics. It suits laboratories that need broad multi-gene information in one assay rather than single-target results.
What is the Benchtop Next-Generation Sequencer for Clinical Use?
A benchtop next-generation sequencer for clinical use reads millions of DNA fragments in parallel to support gene panel testing, oncology profiling, inherited disease testing and pathogen genomics. It suits laboratories that need broad multi-gene information in one assay rather than single-target results.
Overview
This variant uses sequencing by synthesis or semiconductor detection on a flow cell or chip to read libraries prepared from patient DNA or RNA. Typical output ranges from 1 to 100 gigabases per run, with read lengths of 75 to 300 base pairs, and run times of 12 to 48 hours. Targeted panels covering 50 to several hundred genes allow high depth at low cost per sample, and multiplexing with index barcodes pools many samples. The workflow includes library preparation, quantification, loading, sequencing and bioinformatics analysis for alignment, variant calling and annotation. Infrastructure needs include data storage, compute resources and validated pipelines. Instruments intended for clinical use require verification under laboratory quality systems, with attention to accuracy, reproducibility and data privacy.
How does it work?
Molecular diagnostics amplify a specific nucleic acid sequence so that it becomes detectable. In real-time PCR, thermal cycling denatures DNA, anneals primers and extends with a DNA polymerase, while fluorescent probes such as hydrolysis probes emit signal proportional to product accumulation, and the cycle threshold indicates starting quantity. RNA targets are first reverse-transcribed. Isothermal methods such as LAMP amplify at a constant temperature of about 60–65 °C. Digital PCR partitions a sample into thousands of droplets or wells and counts positive partitions for absolute quantification. Sequencing reads the order of bases by synthesis or nanopore detection. Controls such as internal controls and no-template controls verify extraction, amplification and contamination status in each run.
What are the key features?
- Massively parallel sequencing of millions of DNA fragments per run
- Output of 1 to 100 Gb and read lengths of 75–300 bp
- Multiplexing with index barcodes to pool many samples per run
- Targeted panel, exome and transcriptome application support
- Integrated analysis software for alignment and variant calling
- Flow cell and reagent cartridges with barcoded tracking
What are the technical specifications?
A typical benchtop next-generation sequencer for clinical use configuration offers output per run of 1–100 Gb, read length of 75–300 bp (paired-end), run time of 12–48 h, reads per run of 4–400 million, base accuracy of ≥ 99.9% (Q30 ≥ 85%) and sample multiplexing of Up to 96 or more index barcodes. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Benchtop Next-Generation Sequencer for Clinical Use is used in oncology gene panel testing, inherited disease and carrier screening, pathogen genomics and surveillance, non-invasive prenatal testing and pharmacogenomics. Across the wider Molecular Diagnostics class, laboratories also deploy it for infectious disease PCR testing, oncology mutation testing and genetic and inherited disease testing.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, IEC 61010-2-101, CLSI MM03, CLSI MM06, CLSI EP17, ISO 20395, ISO 13485 and ISO 17822. Certification candidates for this model are CE, ISO 13485 quality system and NMPA registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Molecular laboratories require unidirectional workflow with separate areas for reagent preparation, sample processing, amplification and post-amplification where applicable, or closed systems that reduce contamination risk. Use dedicated pipettes, filter tips, UV decontamination and routine surface cleaning. Calibrate thermal blocks and optical systems, and run positive, negative and internal controls in each run. Protect instruments from dust and vibration, use stable power, and follow reagent cold-chain requirements. Validate assays and instrument performance according to CLSI MM guidelines and laboratory procedures under ISO 15189. Manage biosafety for pathogen work and handle data with privacy controls, especially for genetic information.
How do I select the right Benchtop Next-Generation Sequencer for Clinical Use?
Choose a benchtop sequencer when multi-gene information is needed in one assay. Specify output, read length, samples per run, turnaround, supported applications, bioinformatics pipeline, data storage, reagent supply and local regulatory requirements for clinical use in the RFQ, and plan staff skills.
How does it compare with other Molecular Diagnostics variants?
Choose by assay type, volume and laboratory skill level. Real-time PCR suits high-volume batch testing with open or closed assays. Sample-to-answer cartridge systems offer minimal hands-on time and fast results for low-volume or urgent testing. Digital PCR suits absolute quantification, rare variant detection and minimal residual disease. Isothermal analyzers fit decentralized settings with simple instrumentation. Sequencers suit broad genetic, oncology and pathogen genomics panels. Compare channels, throughput, sample volume, limit of detection, workflow steps, contamination control, and software for result interpretation. Verify assay availability and registration in your market, open channel versatility, LIS connectivity and service support, and plan laboratory zoning and staff training.
Full specifications
| Output per run | 1–100 Gb |
|---|---|
| Read length | 75–300 bp (paired-end) |
| Run time | 12–48 h |
| Reads per run | 4–400 million |
| Base accuracy | ≥ 99.9% (Q30 ≥ 85%) |
| Sample multiplexing | Up to 96 or more index barcodes |
| Applications | Gene panel, exome, transcriptome, microbial genomics |
| Onboard compute | Integrated analysis workstation |
| Data storage | 1–8 TB local storage |
| Power supply | 100–240 V AC, 50/60 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Oncology gene panel testing
- Inherited disease and carrier screening
- Pathogen genomics and surveillance
- Non-invasive prenatal testing
- Pharmacogenomics
Key features
- Massively parallel sequencing of millions of DNA fragments per run
- Output of 1 to 100 Gb and read lengths of 75–300 bp
- Multiplexing with index barcodes to pool many samples per run
- Targeted panel, exome and transcriptome application support
- Integrated analysis software for alignment and variant calling
- Flow cell and reagent cartridges with barcoded tracking
Frequently asked questions about Benchtop Next-Generation Sequencer for Clinical Use
Beyond the instrument, laboratories need library preparation space, quantification tools, secure data storage, validated bioinformatics pipelines and trained staff. Data volumes are large, so storage, backup and computing capacity should be planned from the outset.
Raw base accuracy is typically above 99.9 percent, and accuracy improves with read depth and confirmation of variants. Clinical laboratories validate each assay for sensitivity and specificity, often requiring orthogonal confirmation for key variants.
Runs take roughly 12 to 48 hours depending on read length and output, plus library preparation and analysis time. Small instruments and targeted panels can deliver results in one to three days from receipt of specimen.
It is the group of instruments that detect or quantify DNA and RNA in clinical specimens, typically by amplification such as PCR or by sequencing. Applications include infectious disease testing, oncology mutations, genetic disorders and viral load monitoring.
Real-time PCR estimates starting quantity from the cycle at which fluorescence crosses a threshold and needs a standard curve. Digital PCR partitions the sample and counts positive partitions for absolute quantification without a curve, which improves detection of rare variants.
Laboratories use separated pre- and post-amplification areas, unidirectional workflow, filter tips, UV decontamination and no-template controls. Closed cartridge systems and uracil-N-glycosylase in reagent mixes further reduce the risk of amplicon carryover.
Related models