Skip to main content
Lab Manufacturers China
Dry Fluorescence Immunoassay Quantitative Analyzer — product photo

Dry Fluorescence Immunoassay Quantitative Analyzer

干式荧光免疫定量分析仪

  • SKU IMM-0004
  • Immunodiagnostics
  • CE (to be confirmed)
  • ISO 13485 quality system (to be confirmed)
  • NMPA registration (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Detection methodFluorescence immunochromatography
Time to result3–15 min
Sample volume10–100 µL
Sample typesWhole blood, serum, plasma
Excitation sourceLED, ≈ 365 nm
Channels1–6 cartridges concurrently
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, IEC 61010-2-101, ISO 18113-1

What is the Dry Fluorescence Immunoassay Quantitative Analyzer?

A dry fluorescence immunoassay quantitative analyzer reads single-use cartridges or strips labeled with fluorescent particles to quantify markers such as troponin, CRP and D-dimer in minutes. It suits emergency departments, small laboratories and clinics needing quick, low-volume immunoassay testing.

What is the Dry Fluorescence Immunoassay Quantitative Analyzer?

A dry fluorescence immunoassay quantitative analyzer reads single-use cartridges or strips labeled with fluorescent particles to quantify markers such as troponin, CRP and D-dimer in minutes. It suits emergency departments, small laboratories and clinics needing quick, low-volume immunoassay testing.

Overview

This variant reads immunochromatographic cartridges in which a sample migrates across a membrane and binds fluorescent-labeled antibodies to form lines at defined positions. A compact optical reader excites the labels, often with an LED at around 365 nm, and measures emission to calculate concentration from a lot-specific calibration stored on a chip or barcode. Results are available in 3 to 15 minutes from 10 to 100 microliters of whole blood, serum or plasma. Typical menus cover cardiac markers, CRP, procalcitonin, D-dimer, HbA1c and hormones. Benchtop readers handle single or multiple tests concurrently, with touchscreens and printers. Quantitative fluorescence provides better sensitivity and range than visual rapid tests, but precision is lower than large central laboratory analyzers.

How does it work?

Immunodiagnostic platforms exploit the specific binding of an antibody to its antigen. In a sandwich assay, a capture antibody on a solid phase such as a magnetic microparticle or microplate binds the analyte, and a labeled detection antibody forms a complex whose signal is proportional to concentration. In competitive assays, labeled and sample antigens compete for limited antibody sites and signal falls as concentration rises. Labels include enzymes such as horseradish peroxidase or alkaline phosphatase, acridinium esters or ruthenium complexes for luminescence, and lanthanide chelates or fluorophores. After incubation and washing to remove unbound label, a photomultiplier, fluorometer or photometer measures the signal, and a calibration curve converts it to concentration. Automation handles pipetting, incubation, washing and result calculation.

What are the key features?

  • Single-use cartridges with fluorescent-labeled antibodies on membrane
  • Result in 3–15 minutes from 10–100 µL of whole blood or serum
  • Lot-specific calibration loaded through chip or barcode
  • Compact benchtop reader with touchscreen and thermal printer
  • Menu of cardiac markers, CRP, procalcitonin, D-dimer and HbA1c
  • Connectivity via USB, Ethernet or Wi-Fi for result transfer

What are the technical specifications?

A typical dry fluorescence immunoassay quantitative analyzer configuration offers detection method of Fluorescence immunochromatography, time to result of 3–15 min, sample volume of 10–100 µL, sample types of Whole blood, serum, plasma, excitation source of LED, ≈ 365 nm and channels of 1–6 cartridges concurrently. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Dry Fluorescence Immunoassay Quantitative Analyzer is used in emergency cardiac marker testing, inflammation and sepsis triage, clinic and outpatient testing and small hospital laboratories. Across the wider Immunodiagnostics class, laboratories also deploy it for infectious disease serology screening, thyroid and reproductive hormone testing and tumor marker monitoring.

Which standards and certifications apply?

Relevant standards and methods include ISO 15189, IEC 61010-2-101, ISO 18113-1, CLSI EP05, CLSI EP07, CLSI EP17, CLSI I/LA23 and ISO 13485. Certification candidates for this model are CE, ISO 13485 quality system and NMPA registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Place analyzers on a stable bench with temperature and humidity within the stated range, away from direct sunlight, and provide purified water, waste drainage and stable power where required. Follow maintenance schedules for washing systems, probes and optics, and run daily controls at several levels. Verify new lots and calibration according to laboratory procedures, and monitor for interferences such as biotin, heterophilic antibodies or the hook effect. Store reagents at 2–8 °C and observe onboard stability. Handle specimens as potentially infectious, dispose of liquid waste according to biosafety rules, and document maintenance, calibration and operator competence under ISO 15189. Plan service coverage and reagent logistics for the market.

How do I select the right Dry Fluorescence Immunoassay Quantitative Analyzer?

Choose dry fluorescence readers when speed and simplicity outweigh the need for high throughput. Specify the test menu, sample types, daily volume, connectivity, operator training and cartridge storage conditions in the RFQ, and compare cost per test and precision with central analyzers.

How does it compare with other Immunodiagnostics variants?

Match the platform to menu and volume. Chemiluminescence and electrochemiluminescence systems offer wide dynamic range and high sensitivity for hormones, tumor markers and infectious disease serology at medium to high volume. Time-resolved fluorescence suits low-concentration analytes such as newborn screening and fertility hormones. Dry fluorescence readers with cartridges serve small laboratories and emergency testing for cardiac markers. ELISA remains flexible and economical for batch testing and blood screening. Compare reagent menu, closed or open status, onboard reagent stability, sample volume, calibration interval, throughput in tests per hour, and LIS connectivity. Confirm reagent registration in your market, supply reliability and cost per reportable result.

Full specifications

Full specifications
Detection methodFluorescence immunochromatography
Time to result3–15 min
Sample volume10–100 µL
Sample typesWhole blood, serum, plasma
Excitation sourceLED, ≈ 365 nm
Channels1–6 cartridges concurrently
Precision (CV)≤ 10–15%
Storage of results≥ 10,000 records
Display7-inch color touchscreen
Power supply100–240 V AC or rechargeable battery

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Emergency cardiac marker testing
  • Inflammation and sepsis triage
  • Clinic and outpatient testing
  • Small hospital laboratories

Key features

  • Single-use cartridges with fluorescent-labeled antibodies on membrane
  • Result in 3–15 minutes from 10–100 µL of whole blood or serum
  • Lot-specific calibration loaded through chip or barcode
  • Compact benchtop reader with touchscreen and thermal printer
  • Menu of cardiac markers, CRP, procalcitonin, D-dimer and HbA1c
  • Connectivity via USB, Ethernet or Wi-Fi for result transfer

Frequently asked questions about Dry Fluorescence Immunoassay Quantitative Analyzer

Precision is usually a coefficient of variation of 5 to 15 percent, which is adequate for triage and monitoring but less tight than central analyzers. Correlation with laboratory methods should be verified locally, and results for critical decisions are often confirmed by the laboratory.

Request a quotation for the Dry Fluorescence Immunoassay Quantitative Analyzer

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote