High-Resolution Echelle ICP-OES Spectrometer

高分辨率中阶梯光栅 ICP-OES 光谱仪

  • SKU ICO-0006
  • ICP-OES
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • 21 CFR Part 11 software compliance (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Wavelength range165–850 nm
Optical resolution≤ 0.005 nm at 200 nm
Detectorlarge CCD or CMOS array
Dispersionechelle grating plus prism
Simultaneous elementsup to 70
Detection limit0.5–10 µg/L typical
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <730> Plasma Spectrochemistry, USP <233> Elemental Impurities — Procedures, ICH Q3D Elemental Impurities

What is the High-Resolution Echelle ICP-OES Spectrometer?

A high-resolution echelle ICP-OES spectrometer resolves closely spaced emission lines in composite, line-rich spectra. It is chosen for difficult rare-earth, iron-rich and similar samples where unresolved line overlap otherwise causes quantitation errors.

What is the High-Resolution Echelle ICP-OES Spectrometer?

A high-resolution echelle ICP-OES spectrometer resolves closely spaced emission lines in composite, line-rich spectra. It is chosen for difficult rare-earth, iron-rich and similar samples where unresolved line overlap otherwise causes quantitation errors.

Overview

Echelle optics combine a coarse echelle grating with a cross-disperser prism to produce a two-dimensional spectrum of high resolution and wide coverage on a single detector. This design resolves lines that are only fractions of a nanometre apart, which is essential when the sample emits a dense spectrum, such as rare-earth elements with hundreds of lines or iron-rich alloys where iron lines overlap analyte lines. The two-dimensional pattern is captured by a large array detector so many lines are measured simultaneously. Resolution is typically better than 0.005 nanometres in the ultraviolet. High-resolution instruments also improve detection limits by separating analyte lines from nearby interference and are widely used in geochemistry, metallurgy and advanced materials analysis where line-rich matrices are routine.

How does it work?

A radio-frequency generator drives a load coil around a quartz torch, sustaining an argon plasma at 6000 to 10000 K. The sample aerosol enters the plasma and is desolvated, vaporized, atomized and excited. Excited atoms and ions relax and emit light at wavelengths characteristic of each element. The emitted light is dispersed by an echelle grating or a CCD-based polychromator, and multiple lines are measured simultaneously. In radial viewing the plasma is observed from the side, which tolerates high dissolved solids and reduces self-absorption; in axial viewing the plasma is observed end-on, which lengthens the optical path and lowers detection limits. Dual-view instruments switch per element. Internal standards, background correction and interference algorithms correct for drift and overlapping lines. The wide dynamic range lets major, minor and trace elements be measured in one run.

What are the key features?

  • Echelle grating with cross-disperser prism
  • Two-dimensional spectrum on a large array detector
  • Resolution better than 0.005 nm in the ultraviolet
  • Resolves line-rich rare-earth and iron matrices
  • Simultaneous measurement of many lines
  • Improved detection limits by overlap suppression

What are the technical specifications?

A typical high-resolution echelle icp-oes spectrometer configuration offers wavelength range of 165–850 nm, optical resolution of ≤ 0.005 nm at 200 nm, detector of large CCD or CMOS array, dispersion of echelle grating plus prism, simultaneous elements of up to 70 and detection limit of 0.5–10 µg/L typical. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The High-Resolution Echelle ICP-OES Spectrometer is used in rare-earth element analysis, iron, steel and alloy trace analysis, geological and geochemical research and advanced materials and catalyst testing. Across the wider ICP-OES class, laboratories also deploy it for multi-element water and wastewater analysis, pharmaceutical elemental impurity screening and food, feed and agricultural element analysis.

Which standards and certifications apply?

Relevant standards and methods include USP <730> Plasma Spectrochemistry, USP <233> Elemental Impurities — Procedures, ICH Q3D Elemental Impurities, ISO 11885 Water quality — ICP-OES determination of elements, US EPA Method 200.7, ASTM D5185 and ISO/IEC 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and 21 CFR Part 11 software compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

ICP-OES requires high-purity argon, substantial power, exhaust ventilation and a temperature-controlled room. Torch, injector and nebulizer condition strongly affect performance, so inspection and replacement schedules are important. High dissolved solids cause salt build-up on the torch and injector, blocking the plasma and changing sensitivity, so dilution and matrix matching are used. Sample preparation by acid digestion must avoid contamination. Daily checks include wavelength calibration, torch alignment, plasma stability and a check standard. Monitor the argon supply and the chiller, and record torch and nebulizer usage. Data integrity requires calibration verification, QC samples and defined acceptance criteria.

How do I select the right High-Resolution Echelle ICP-OES Spectrometer?

Select a high-resolution echelle instrument when the sample matrix produces dense spectra and line overlap is the limiting factor, as in rare-earth or iron-rich materials. Specify the elements and known interferences, and confirm the resolution and wavelength coverage for the critical lines. Compare with ICP-MS if the main limitation is detection limit rather than resolution.

How does it compare with other ICP-OES variants?

Select an ICP-OES spectrometer by viewing configuration, detector type, resolution and automation. Radial viewing is the best choice for high-matrix samples and major elements, axial viewing for the lowest detection limits in clean samples, and dual view for laboratories that handle both. Simultaneous CCD instruments measure many elements and lines quickly, while sequential scanning instruments are flexible and lower in cost but slower. High-resolution echelle optics help when many emission lines overlap, as in rare-earth or iron-rich samples. Confirm the wavelength range covers the elements and lines you need, including far-ultraviolet lines for halogens. Check argon and power consumption, sample introduction options, autosampler capacity and software features such as interference correction and audit trails.

Full specifications

Full specifications
Wavelength range165–850 nm
Optical resolution≤ 0.005 nm at 200 nm
Detectorlarge CCD or CMOS array
Dispersionechelle grating plus prism
Simultaneous elementsup to 70
Detection limit0.5–10 µg/L typical
Viewing modeaxial, radial or dual
RF power1000–1600 W
Argon consumption14–20 L/min
Autosamplerup to 240 positions

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Rare-earth element analysis
  • Iron, steel and alloy trace analysis
  • Geological and geochemical research
  • Advanced materials and catalyst testing

Key features

  • Echelle grating with cross-disperser prism
  • Two-dimensional spectrum on a large array detector
  • Resolution better than 0.005 nm in the ultraviolet
  • Resolves line-rich rare-earth and iron matrices
  • Simultaneous measurement of many lines
  • Improved detection limits by overlap suppression

Frequently asked questions about High-Resolution Echelle ICP-OES Spectrometer

Line overlap is most serious with rare-earth elements, which emit hundreds of lines, and with iron, cobalt, nickel and tungsten-rich matrices where matrix lines fall on analyte wavelengths. It causes positive bias and poor detection limits. High resolution, alternative lines and mathematical correction mitigate it.

Related models

All ICP-OES

Request a quotation for the High-Resolution Echelle ICP-OES Spectrometer