Simultaneous Multi-Element ICP-OES Spectrometer

多元素同时测定 ICP-OES 光谱仪

  • SKU ICO-0004
  • ICP-OES
  • CE (to be confirmed)
  • ISO 9001 manufacturing (to be confirmed)
  • 21 CFR Part 11 software compliance (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Wavelength range165–900 nm
Detectionsimultaneous array
DetectorCCD or CMOS array
Simultaneous elementsup to 70
Analysis time10–30 s per sample
Detection limit0.5–10 µg/L typical
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: USP <730> Plasma Spectrochemistry, USP <233> Elemental Impurities — Procedures, ICH Q3D Elemental Impurities

What is the Simultaneous Multi-Element ICP-OES Spectrometer?

A simultaneous ICP-OES spectrometer records many wavelengths at once with a large array detector and no scanning. It is chosen for busy high-throughput laboratories that measure large element panels in a single fast reading.

What is the Simultaneous Multi-Element ICP-OES Spectrometer?

A simultaneous ICP-OES spectrometer records many wavelengths at once with a large array detector and no scanning. It is chosen for busy high-throughput laboratories that measure large element panels in a single fast reading.

Overview

This instrument uses a fixed echelle or similar polychromator with a large CCD or CMOS array, so light at all the analytical wavelengths falls on the detector simultaneously and is read in one integration. Every element and line in the method is acquired at once, which reduces analysis time to a few seconds per sample and improves precision because all lines share the same plasma conditions. The design is well suited to large element panels, such as full impurity screens or multi-element water methods, and to laboratories with high sample numbers. Because the wavelength positions are fixed by calibration rather than scanned, stability of the optics is critical, and periodic wavelength calibration is required. Detector segmenting and dynamic range management handle both weak and strong lines. The approach pairs naturally with autosamplers and with internal standard correction.

How does it work?

A radio-frequency generator drives a load coil around a quartz torch, sustaining an argon plasma at 6000 to 10000 K. The sample aerosol enters the plasma and is desolvated, vaporized, atomized and excited. Excited atoms and ions relax and emit light at wavelengths characteristic of each element. The emitted light is dispersed by an echelle grating or a CCD-based polychromator, and multiple lines are measured simultaneously. In radial viewing the plasma is observed from the side, which tolerates high dissolved solids and reduces self-absorption; in axial viewing the plasma is observed end-on, which lengthens the optical path and lowers detection limits. Dual-view instruments switch per element. Internal standards, background correction and interference algorithms correct for drift and overlapping lines. The wide dynamic range lets major, minor and trace elements be measured in one run.

What are the key features?

  • Fixed polychromator with large array detector
  • All analytical wavelengths acquired in one integration
  • Few seconds per sample for large element panels
  • Improved precision from shared plasma conditions
  • Periodic wavelength calibration for fixed optics
  • Internal standard and dynamic range correction

What are the technical specifications?

A typical simultaneous multi-element icp-oes spectrometer configuration offers wavelength range of 165–900 nm, detection of simultaneous array, detector of CCD or CMOS array, simultaneous elements of up to 70, analysis time of 10–30 s per sample and detection limit of 0.5–10 µg/L typical. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Simultaneous Multi-Element ICP-OES Spectrometer is used in full elemental impurity panels, large multi-element water methods, food and feed multi-element screening and high-throughput contract analysis. Across the wider ICP-OES class, laboratories also deploy it for multi-element water and wastewater analysis, pharmaceutical elemental impurity screening and food, feed and agricultural element analysis.

Which standards and certifications apply?

Relevant standards and methods include USP <730> Plasma Spectrochemistry, USP <233> Elemental Impurities — Procedures, ICH Q3D Elemental Impurities, ISO 11885 Water quality — ICP-OES determination of elements, US EPA Method 200.7, ASTM D5185 and ISO/IEC 17025. Certification candidates for this model are CE, ISO 9001 manufacturing and 21 CFR Part 11 software compliance; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

ICP-OES requires high-purity argon, substantial power, exhaust ventilation and a temperature-controlled room. Torch, injector and nebulizer condition strongly affect performance, so inspection and replacement schedules are important. High dissolved solids cause salt build-up on the torch and injector, blocking the plasma and changing sensitivity, so dilution and matrix matching are used. Sample preparation by acid digestion must avoid contamination. Daily checks include wavelength calibration, torch alignment, plasma stability and a check standard. Monitor the argon supply and the chiller, and record torch and nebulizer usage. Data integrity requires calibration verification, QC samples and defined acceptance criteria.

How do I select the right Simultaneous Multi-Element ICP-OES Spectrometer?

Select a simultaneous instrument when methods contain many elements and lines and sample numbers are high, because per-sample time dominates cost. Specify the element panel, required detection limits and throughput, and confirm that the fixed wavelength coverage includes all your lines. Periodic wavelength calibration and optical stability checks are essential.

How does it compare with other ICP-OES variants?

Select an ICP-OES spectrometer by viewing configuration, detector type, resolution and automation. Radial viewing is the best choice for high-matrix samples and major elements, axial viewing for the lowest detection limits in clean samples, and dual view for laboratories that handle both. Simultaneous CCD instruments measure many elements and lines quickly, while sequential scanning instruments are flexible and lower in cost but slower. High-resolution echelle optics help when many emission lines overlap, as in rare-earth or iron-rich samples. Confirm the wavelength range covers the elements and lines you need, including far-ultraviolet lines for halogens. Check argon and power consumption, sample introduction options, autosampler capacity and software features such as interference correction and audit trails.

Full specifications

Full specifications
Wavelength range165–900 nm
Detectionsimultaneous array
DetectorCCD or CMOS array
Simultaneous elementsup to 70
Analysis time10–30 s per sample
Detection limit0.5–10 µg/L typical
Optical resolution≤ 0.009 nm at 200 nm
RF power1000–1500 W
Argon consumption14–18 L/min
Autosamplerup to 240 positions

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Full elemental impurity panels
  • Large multi-element water methods
  • Food and feed multi-element screening
  • High-throughput contract analysis

Key features

  • Fixed polychromator with large array detector
  • All analytical wavelengths acquired in one integration
  • Few seconds per sample for large element panels
  • Improved precision from shared plasma conditions
  • Periodic wavelength calibration for fixed optics
  • Internal standard and dynamic range correction

Frequently asked questions about Simultaneous Multi-Element ICP-OES Spectrometer

Once the plasma is stable and the autosampler delivers the sample, a full element panel is usually acquired in 10 to 30 seconds, including rinse and integration. Additional lines for confirmation or interference checks add little time because they are recorded simultaneously.