Flame Atomic Absorption Spectrometer for Metals in Water

水中金属测定火焰原子吸收光谱仪

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Wavelength range190–900 nm
Wavelength accuracy± 0.25 nm
Spectral bandwidth0.1, 0.2, 0.4, 1.3 nm
Background correctionDeuterium lamp or Zeeman
Characteristic concentration (Cu)≤ 0.03 mg/L (1% absorption)
Detection limit (Cu)≤ 0.006 mg/L
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15586, ISO 17294-2, ISO 11885

What is the Flame Atomic Absorption Spectrometer for Metals in Water?

A flame AAS with air-acetylene burner and hollow cathode lamps for copper, zinc, iron, manganese, chromium, nickel and other metals in water. It is a fast, economical workhorse for mg/L to high-µg/L determinations in drinking water and effluents.

What is the Flame Atomic Absorption Spectrometer for Metals in Water?

A flame AAS with air-acetylene burner and hollow cathode lamps for copper, zinc, iron, manganese, chromium, nickel and other metals in water. It is a fast, economical workhorse for mg/L to high-µg/L determinations in drinking water and effluents.

Overview

This variant aspirates digested or filtered water samples through a nebulizer into an air-acetylene flame, typically 2300 °C, where metals are atomized and absorb light from a hollow cathode lamp at 324.8 nm for copper, 213.9 nm for zinc or 248.3 nm for iron. A deuterium or Zeeman background corrector compensates for non-specific absorption. A four- or six-lamp turret, automatic wavelength setting and autosampler allow multi-element sequences, with rates of 10 to 15 seconds per determination. Characteristic concentrations are about 0.03 mg/L for copper, and detection limits are 5–20 µg/L depending on element. A nitrous oxide-acetylene burner extends coverage to refractory elements such as aluminum. Flame systems are robust and inexpensive to run, but they need acetylene handling, safety interlocks and exhaust. They cannot reach the sub-µg/L levels required for lead, cadmium or arsenic in drinking water without preconcentration.

How does it work?

Heavy metal analyzers rely on electrochemical or atomic spectroscopic principles. In anodic stripping voltammetry (ASV), metals are first deposited onto a working electrode at a negative potential, then re-oxidized by a potential sweep, and the stripping current peak at a characteristic potential is proportional to concentration. In atomic absorption spectrometry (AAS), a sample is atomized in a flame or graphite furnace and a hollow cathode lamp beam is absorbed at the metal's wavelength according to Beer–Lambert law. Atomic fluorescence spectrometry (AFS) generates mercury or arsenic hydrides by reaction with borohydride, excites the atoms with a lamp and detects the emitted fluorescence at right angles. Calibration with certified standards, matrix modification and blank correction yield concentrations in µg/L.

What are the key features?

  • Air-acetylene burner with optional nitrous oxide head for refractory elements
  • Four- or six-lamp turret with automatic wavelength and slit setting
  • Deuterium or Zeeman background correction for non-specific absorption
  • Automatic flame safety interlocks for gas pressure, flame and burner type
  • Autosampler with 60 to 120 positions for multi-element sequences
  • Software with method library for GB 5749 and HJ metal methods

What are the technical specifications?

A typical flame atomic absorption spectrometer for metals in water configuration offers wavelength range of 190–900 nm, wavelength accuracy of ± 0.25 nm, spectral bandwidth of 0.1, 0.2, 0.4, 1.3 nm, background correction of Deuterium lamp or Zeeman, characteristic concentration (Cu) of ≤ 0.03 mg/L (1% absorption) and detection limit (Cu) of ≤ 0.006 mg/L. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Flame Atomic Absorption Spectrometer for Metals in Water is used in copper, zinc, iron and manganese in drinking water, electroplating and metal-finishing wastewater, chromium and nickel monitoring in effluents and routine environmental laboratory metal analysis. Across the wider Heavy Metal Analyzers class, laboratories also deploy it for drinking water lead, cadmium and arsenic compliance, industrial wastewater discharge metal monitoring and mercury and arsenic determination in surface water.

Which standards and certifications apply?

Relevant standards and methods include ISO 15586, ISO 17294-2, ISO 11885, ISO 17852, ISO 11969, HJ 694, HJ 700, GB/T 5750.6, ASTM D3559 and IEC 61010-1. Certification candidates for this model are CE and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Trace metal work starts with contamination control: use acid-washed plastic containers, high-purity nitric acid and ultrapure water, and preserve samples to pH below 2. Digest samples containing particulates or organics according to the method before analysis. Calibrate with a blank and at least three standards and verify with independent check standards, spikes and duplicates each batch. AAS and AFS need compressed gases, exhaust ventilation and lamp warm-up, and mercury methods need gold-trap or cold-vapor handling. Electrodes for ASV need polishing or replacement of mercury-free film. Handle acid, mercury and arsenic waste under local hazardous waste rules. Use instruments in rooms with stable temperature and follow IEC 61010-1 safety requirements.

How do I select the right Flame Atomic Absorption Spectrometer for Metals in Water?

Choose flame AAS for common metals at mg/L and high µg/L levels, where throughput, robustness and low running cost matter. For sub-µg/L lead or cadmium, select graphite furnace AAS or ICP-MS. In an RFQ, specify elements and ranges, lamp count, background correction, autosampler capacity, gas supply arrangement and safety requirements for acetylene.

How does it compare with other Heavy Metal Analyzers variants?

Match the technique to the metals, detection limits and workload. For lead, cadmium, copper and zinc screening at low cost, stripping voltammetry offers µg/L sensitivity and portability. Mercury, arsenic, selenium and antimony at sub-µg/L are best served by atomic fluorescence with hydride generation. Flame AAS handles mg/L to high µg/L levels of common metals such as copper, zinc, iron and chromium quickly and economically. Graphite furnace AAS reaches sub-µg/L for cadmium, lead and chromium with tiny sample volumes but at lower throughput. If you must analyze many elements simultaneously at ng/L levels, ICP-MS is a different class of instrument. Consider the regulatory limit, sample numbers, digestion needs, gases required, operator skill and whether results must follow a named method such as HJ 694 or ISO 15586.

Full specifications

Full specifications
Wavelength range190–900 nm
Wavelength accuracy± 0.25 nm
Spectral bandwidth0.1, 0.2, 0.4, 1.3 nm
Background correctionDeuterium lamp or Zeeman
Characteristic concentration (Cu)≤ 0.03 mg/L (1% absorption)
Detection limit (Cu)≤ 0.006 mg/L
RepeatabilityRSD ≤ 1%
Lamp positions4 or 6
GasesAcetylene 99.9%, compressed air; N2O optional
Power supplyAC 220 V, 50 Hz, 1000 VA

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Copper, zinc, iron and manganese in drinking water
  • Electroplating and metal-finishing wastewater
  • Chromium and nickel monitoring in effluents
  • Routine environmental laboratory metal analysis

Key features

  • Air-acetylene burner with optional nitrous oxide head for refractory elements
  • Four- or six-lamp turret with automatic wavelength and slit setting
  • Deuterium or Zeeman background correction for non-specific absorption
  • Automatic flame safety interlocks for gas pressure, flame and burner type
  • Autosampler with 60 to 120 positions for multi-element sequences
  • Software with method library for GB 5749 and HJ metal methods

Frequently asked questions about Flame Atomic Absorption Spectrometer for Metals in Water

Clear aqueous samples with metal concentrations above about 0.01–0.1 mg/L, after acid digestion if turbid or organic-rich. Samples with very high dissolved solids can clog the burner, so dilute or use matrix matching.