Manual Histology Staining Station
手工组织学染色工作站
- SKU HIS-0001
- Histology Stainers
- CE (to be confirmed)
- IEC 61010-1 compliance (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Staining bath count | 10–20 baths |
|---|---|
| Bath volume | about 200–300 mL |
| Slide capacity per rack | 20–30 slides |
| Sink supply | Running water inlet |
| Exhaust airflow | about 0.3–0.5 m/s face velocity |
| Bench material | Solvent-resistant phenolic resin |
By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-101, IEC 61326-1
What is the Manual Histology Staining Station?
A manual histology staining station groups staining baths, a running-water sink and a fume hood into one bench arrangement. It gives the technician full control and is used where volume is low or protocols vary.
What is the Manual Histology Staining Station?
A manual histology staining station groups staining baths, a running-water sink and a fume hood into one bench arrangement. It gives the technician full control and is used where volume is low or protocols vary.
Overview
The manual staining station is the reference against which automated stainers are judged. It usually comprises a row of glass or plastic staining baths in a rack, a running-water sink for rinsing, a differentiation bath, dehydrating alcohols and clearing agent, plus local exhaust ventilation for xylene or substitute solvents. Technicians move slide racks by hand, timing each step with a clock and judging colour development visually. The advantages are flexibility, low cost and immediate control when a protocol fails or a special case needs adjustment. The disadvantages are operator-to-operator variability, occupational exposure to solvents and dyes, and the labour required for large batches. Fume extraction, spill containment and a solvent-resistant bench are essential, and timed baths or a movable rack aid consistency.
How does it work?
A histology stainer automates the sequence of deparaffinisation, hydration, staining, differentiation, dehydration and clearing that a technician would perform by hand. Slides are held in racks or on a conveyor, and the instrument moves them between reagent baths for set dwell times, then transfers them to running water or a rinse station. Hematoxylin stains nucleic acids blue, eosin counterstains cytoplasm pink, and differentiation in acid alcohol tunes the contrast. Special stains such as Periodic Acid-Schiff, Masson trichrome or reticulin use different reagent sequences. Consistency comes from controlled dwell time, reagent concentration, agitation and temperature, while carryover is managed by draining and rinse stations. Automated coverslipping may follow on the same platform.
What are the key features?
- Row of staining baths with slide rack handling
- Running-water sink and differentiation station
- Local exhaust ventilation for solvent vapours
- Solvent-resistant bench and spill containment
- Full operator control of timing and colour
- Low cost and flexible protocol changes
What are the technical specifications?
A typical manual histology staining station configuration offers staining bath count of 10–20 baths, bath volume of about 200–300 mL, slide capacity per rack of 20–30 slides, sink supply of Running water inlet, exhaust airflow of about 0.3–0.5 m/s face velocity and bench material of Solvent-resistant phenolic resin. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Manual Histology Staining Station is used in low-volume pathology laboratories, teaching and training, special stains and unusual protocols and method development. Across the wider Histology Stainers class, laboratories also deploy it for routine H&E staining in pathology, special stains and immunohistochemistry counterstaining.
Which standards and certifications apply?
Relevant standards and methods include IEC 61010-1, IEC 61010-2-101, IEC 61326-1 and ISO 15189. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Install the stainer near a water supply and drain if it needs running water, and on a level bench away from direct sunlight that fades dyes. Reagents degrade with use and evaporation, so set replacement schedules based on slide counts and monitor staining quality with control slides. Clean baths and tubing regularly to prevent precipitate and microbial growth, and check that the differentiation step gives reproducible contrast. Record reagent changes, quality control results and maintenance. Train staff on loading orientation, since misplaced slides cause uneven staining, and on safe handling of xylene, alcohol and carcinogenic dyes.
How do I select the right Manual Histology Staining Station?
Choose a manual station when volume is modest, when protocols change often, or when training staff to understand staining. Confirm adequate local exhaust ventilation, a solvent-resistant bench and safe solvent storage. For more than about 100 slides per day, the labour and variability usually justify an automated stainer.
How does it compare with other Histology Stainers variants?
Select a stainer by throughput, reagent menu and the level of walk-away automation required. Manual staining stations cost least and give full control for low volumes and teaching. Linear stainers move racks along a track through fixed baths and suit routine H&E at moderate volume. Fully automated H&E stainers program time, temperature and agitation, and can process hundreds of slides per hour. Special stain stainers handle individual protocols for trichrome, PAS, reticulin or Gram staining. Compact benchtop models fit small laboratories. Compare slides per run, reagent station count and volume, program capacity, carryover prevention and whether a coverslipper can be integrated. Confirm reagent compatibility and the cost of consumables.
Full specifications
| Staining bath count | 10–20 baths |
|---|---|
| Bath volume | about 200–300 mL |
| Slide capacity per rack | 20–30 slides |
| Sink supply | Running water inlet |
| Exhaust airflow | about 0.3–0.5 m/s face velocity |
| Bench material | Solvent-resistant phenolic resin |
| Timing aid | Interval timer or timed baths |
| Power supply | 220 V, 50 Hz |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Low-volume pathology laboratories
- Teaching and training
- Special stains and unusual protocols
- Method development
Key features
- Row of staining baths with slide rack handling
- Running-water sink and differentiation station
- Local exhaust ventilation for solvent vapours
- Solvent-resistant bench and spill containment
- Full operator control of timing and colour
- Low cost and flexible protocol changes
Frequently asked questions about Manual Histology Staining Station
Yes, especially in small laboratories, for special stains, for teaching and during method development. It remains valuable when a protocol needs judgement, but large routine services generally automate to control variability and solvent exposure.
Work with xylene, alcohol and dye solutions needs local exhaust ventilation, ideally a fume hood or a down-draft bench with a face velocity around 0.3 to 0.5 m/s. General room ventilation alone is usually not sufficient for solvent work.
Use an interval timer with multiple channels, pre-label each bath with the required dwell time, and keep a written schedule for each protocol. Some laboratories use a moving rack in a linear track to standardise transfer intervals without full automation.
It applies routine or special stains to tissue sections by moving slide racks through timed reagent baths. It replaces manual dipping, giving consistent colours across large batches of slides in pathology and research laboratories.
Compact benchtop models handle about 20 to 60 slides per run, linear stainers often 100 to 200, and large automated platforms several hundred slides per hour. Choose capacity to match peak daily volume rather than average load.
Use adequate drainage time and rinse stations, keep reagent volumes above the minimum, and follow the manufacturer schedule for bath cleaning. Carryover shows up as weak or uneven staining, so monitor with control slides and change reagents at defined slide counts.