Skip to main content
Lab Manufacturers China
Automated Special Stains Slide Stainer — product photo

Automated Special Stains Slide Stainer

自动特殊染色机

  • SKU HIS-0004
  • Histology Stainers
  • CE (to be confirmed)
  • IEC 61010-1 compliance (to be confirmed)
  • ISO 13485 manufacturing (to be confirmed)

Price on request — FOB / CIF quoted per order

Prices depend on configuration, quantity and destination port.

Key specifications

Key specifications
Simultaneous protocolsup to 8 on one platform
Slide capacityabout 30–60 slides
Reagent dispensingPrecise per-slide volumes
Dwell timeprogrammable, 1 s to 30 min
Temperature controlambient to 60 °C
Rinse stationsBuffer or running water
Request a quote Download brochure · to be provided

By Lab Manufacturers China Technical TeamLast reviewed Standards: IEC 61010-1, IEC 61010-2-101, IEC 61326-1

What is the Automated Special Stains Slide Stainer?

An automated special stains slide stainer runs protocols such as PAS, trichrome, reticulin or Gram stains with individually timed reagent steps. It is chosen by laboratories that need many different special stains with reproducible results.

What is the Automated Special Stains Slide Stainer?

An automated special stains slide stainer runs protocols such as PAS, trichrome, reticulin or Gram stains with individually timed reagent steps. It is chosen by laboratories that need many different special stains with reproducible results.

Overview

Special stains are numerous and chemically diverse, so a dedicated special stains stainer offers flexible programming rather than a single fixed cycle. Users select a protocol, and the instrument dispenses or transfers reagents to individual slides or slide groups with the required dwell time, rinse and temperature. Some platforms are open systems that accept any reagent, while closed systems use the manufacturer's kits. Common protocols include Periodic Acid-Schiff for glycogen and fungi, Masson trichrome for connective tissue, reticulin for fibre networks, Ziehl-Neelsen for acid-fast bacilli and Gram or Grocott stains for microorganisms. Reagent volumes are sometimes small, so precise dispensing and thorough rinse steps are important to avoid background and carryover, and controls should be run with each batch.

How does it work?

A histology stainer automates the sequence of deparaffinisation, hydration, staining, differentiation, dehydration and clearing that a technician would perform by hand. Slides are held in racks or on a conveyor, and the instrument moves them between reagent baths for set dwell times, then transfers them to running water or a rinse station. Hematoxylin stains nucleic acids blue, eosin counterstains cytoplasm pink, and differentiation in acid alcohol tunes the contrast. Special stains such as Periodic Acid-Schiff, Masson trichrome or reticulin use different reagent sequences. Consistency comes from controlled dwell time, reagent concentration, agitation and temperature, while carryover is managed by draining and rinse stations. Automated coverslipping may follow on the same platform.

What are the key features?

  • Flexible protocols for many special stains
  • Individual slide or slide group processing
  • Precise reagent dispensing with rinse steps
  • Programmable dwell time and temperature
  • Open or closed reagent system options
  • Controls run in the same batch

What are the technical specifications?

A typical automated special stains slide stainer configuration offers simultaneous protocols of up to 8 on one platform, slide capacity of about 30–60 slides, reagent dispensing of Precise per-slide volumes, dwell time of programmable, 1 s to 30 min, temperature control of ambient to 60 °C and rinse stations of Buffer or running water. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.

Which applications is it used for?

The Automated Special Stains Slide Stainer is used in special stains in diagnostic pathology, infectious disease microbiology stains, connective tissue and liver histology and research histology protocols. Across the wider Histology Stainers class, laboratories also deploy it for routine H&E staining in pathology, special stains and immunohistochemistry counterstaining.

Which standards and certifications apply?

Relevant standards and methods include IEC 61010-1, IEC 61010-2-101, IEC 61326-1 and ISO 15189. Certification candidates for this model are CE, IEC 61010-1 compliance and ISO 13485 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.

Install the stainer near a water supply and drain if it needs running water, and on a level bench away from direct sunlight that fades dyes. Reagents degrade with use and evaporation, so set replacement schedules based on slide counts and monitor staining quality with control slides. Clean baths and tubing regularly to prevent precipitate and microbial growth, and check that the differentiation step gives reproducible contrast. Record reagent changes, quality control results and maintenance. Train staff on loading orientation, since misplaced slides cause uneven staining, and on safe handling of xylene, alcohol and carcinogenic dyes.

How do I select the right Automated Special Stains Slide Stainer?

Choose a special stains stainer when your laboratory runs several different special stains regularly and needs reproducible timing across operators. Confirm the number of simultaneously runnable protocols, slide capacity, dispensing precision and whether the system is open to third-party reagents. Evaluate reagent cost, since special stain kits vary widely.

How does it compare with other Histology Stainers variants?

Select a stainer by throughput, reagent menu and the level of walk-away automation required. Manual staining stations cost least and give full control for low volumes and teaching. Linear stainers move racks along a track through fixed baths and suit routine H&E at moderate volume. Fully automated H&E stainers program time, temperature and agitation, and can process hundreds of slides per hour. Special stain stainers handle individual protocols for trichrome, PAS, reticulin or Gram staining. Compact benchtop models fit small laboratories. Compare slides per run, reagent station count and volume, program capacity, carryover prevention and whether a coverslipper can be integrated. Confirm reagent compatibility and the cost of consumables.

Full specifications

Full specifications
Simultaneous protocolsup to 8 on one platform
Slide capacityabout 30–60 slides
Reagent dispensingPrecise per-slide volumes
Dwell timeprogrammable, 1 s to 30 min
Temperature controlambient to 60 °C
Rinse stationsBuffer or running water
Reagent systemOpen or closed kit-based
Carryover controlPrime and rinse cycles
Power supply220 V, 50 Hz, about 0.8 kW

Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.

Applications

  • Special stains in diagnostic pathology
  • Infectious disease microbiology stains
  • Connective tissue and liver histology
  • Research histology protocols

Key features

  • Flexible protocols for many special stains
  • Individual slide or slide group processing
  • Precise reagent dispensing with rinse steps
  • Programmable dwell time and temperature
  • Open or closed reagent system options
  • Controls run in the same batch

Frequently asked questions about Automated Special Stains Slide Stainer

Most routine special stains can be automated, including Periodic Acid-Schiff, Masson trichrome, reticulin, Ziehl-Neelsen, Gram, Grocott methenamine silver and iron stains. Availability depends on whether the instrument is open to any reagent or limited to validated kits.

Request a quotation for the Automated Special Stains Slide Stainer

Send your configuration, quantity and destination port to sales@labmanufacturerschina.com; we reply with a specification sheet and price.

Request a quote