Grain Test Weight Meter
谷物容重仪
- SKU GRA-0005
- Grain Analysis
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measurement | Test weight (bulk density) |
|---|---|
| Measurement range | 50–90 kg/hL |
| Cup volume | 0.25–1 L (standard) |
| Resolution | 0.1 kg/hL |
| Accuracy | ±0.2 kg/hL |
| Drop height | Fixed per standard method |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 712 (moisture), ISO 3093 (falling number), AACC Method 56-81B
What is the Grain Test Weight Meter?
An instrument that determines test weight by filling a calibrated container from a standard hopper. It is the right choice for rapid grading and trade settlement where density indicates grain soundness and milling yield.
What is the Grain Test Weight Meter?
An instrument that determines test weight by filling a calibrated container from a standard hopper. It is the right choice for rapid grading and trade settlement where density indicates grain soundness and milling yield.
Overview
The test weight meter consists of a filling hopper, a funnel or drop mechanism, a calibrated measuring cup and an integrated or separate balance. Grain is poured into the hopper, released through a defined drop height and levelled with a straightedge, and the mass of the filled cup is weighed and converted to test weight in kilograms per hectolitre or pounds per bushel. The standard drop height and cup dimensions are fixed by the method, because how the grain packs strongly affects density. Electronic models weigh the cup automatically, compute the result and log it with sample and moisture data. Test weight is a rapid, low-cost indicator of kernel plumpness and soundness and is widely used in wheat and maize grading. It correlates with milling yield but does not replace protein, moisture or damage analysis.
How does it work?
Grain analysis uses several techniques. Near-infrared instruments measure the reflectance or transmission of light at selected wavelengths, and multivariate calibration models relate the spectra to protein, moisture, oil and starch content. Capacitance moisture meters measure the dielectric constant of a grain sample, which rises with water content, and are calibrated per species and temperature. The falling number apparatus gelatinises a ground grain suspension in a boiling water bath and times the fall of a stirrer through the paste, giving a viscosity-related index of sprout damage and alpha-amylase activity. Gluten content is determined by washing a dough ball mechanically to remove starch, or by near-infrared prediction, and gluten index measures its elasticity. Test weight, or hectolitre weight, is the mass of grain filling a standard volume, measured by a filling hopper and a calibrated container.
What are the key features?
- Standard hopper and drop height give reproducible packing.
- Calibrated cup converts filled mass directly to test weight.
- Electronic balance and display reduce reading errors.
- Results logged with sample identity and moisture data.
- Interchangeable cups support national and imperial units.
- Simple, robust design suits high-throughput intake points.
What are the technical specifications?
A typical grain test weight meter configuration offers measurement of Test weight (bulk density), measurement range of 50–90 kg/hL, cup volume of 0.25–1 L (standard), resolution of 0.1 kg/hL, accuracy of ±0.2 kg/hL and drop height of Fixed per standard method. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Grain Test Weight Meter is used in wheat and maize intake grading, trade settlement and contract checks, storage and drying management and plant breeding yield quality screening. Across the wider Grain Analysis class, laboratories also deploy it for grain elevator intake grading, flour and semolina milling control and feed ingredient quality control.
Which standards and certifications apply?
Relevant standards and methods include ISO 712 (moisture), ISO 3093 (falling number), AACC Method 56-81B, ICC Standard 105/2, ISO 21415-2 (gluten) and GB/T 5498 (test weight). Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Keep near-infrared instruments clean and free of dust, and run the daily check sample supplied with the calibration to detect drift. Store reference samples for the grain species in use and send periodic samples to a reference laboratory for biased calibration updates. For capacitance meters, control sample temperature and fill volume exactly, since both affect readings. The falling number apparatus needs a boiling water bath at a stable rolling boil, correct grinding and accurate timing to meet the standard. Grain samples should be representative, taken with a proper divider, and stored dry to avoid moisture change before analysis. Record instrument settings, sample mass and results so that data can be traced to the method used.
How do I select the right Grain Test Weight Meter?
Select the test weight meter for fast density grading and settlement where a simple, robust result is required. When protein, gluten or moisture are decisive, combine it with NIR or moisture instruments. In an RFQ, specify the units, cup volume, balance accuracy and data logging needs.
How does it compare with other Grain Analysis variants?
Start from the parameters and the reference method required by the trading contract or the internal specification. For rapid multi-parameter grading at intake, near-infrared analyzers give protein, moisture, oil and starch in under a minute and suit high throughput, but their calibrations must cover the grain species, variety groups and moisture ranges encountered. For legally reported moisture, use a capacitance or oven method calibrated to the applicable standard. Select the falling number apparatus when sprout damage or alpha-amylase activity matters for milling and baking. Choose a gluten analyzer when dough strength is the key quality parameter for flour. Confirm sample presentation, calibration maintenance, reference laboratory support and the ability to update models as new varieties are grown.
Full specifications
| Measurement | Test weight (bulk density) |
|---|---|
| Measurement range | 50–90 kg/hL |
| Cup volume | 0.25–1 L (standard) |
| Resolution | 0.1 kg/hL |
| Accuracy | ±0.2 kg/hL |
| Drop height | Fixed per standard method |
| Balance capacity | 2–6 kg |
| Data logging | Up to 1000 records |
| Units | kg/hL, g/L, lb/bu |
| Operating temperature | 10–35 °C |
| Power supply | Battery or mains |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Wheat and maize intake grading
- Trade settlement and contract checks
- Storage and drying management
- Plant breeding yield quality screening
Key features
- Standard hopper and drop height give reproducible packing.
- Calibrated cup converts filled mass directly to test weight.
- Electronic balance and display reduce reading errors.
- Results logged with sample identity and moisture data.
- Interchangeable cups support national and imperial units.
- Simple, robust design suits high-throughput intake points.
Frequently asked questions about Grain Test Weight Meter
It is reported as mass per standard volume, commonly kilograms per hectolitre in metric systems, grams per litre, or pounds per bushel in the United States. The method fixes the cup volume and drop height so results are comparable between laboratories.
How grain packs depends on drop height, flow and vibration, so a loosely filled cup reads lower than a settled one. The standard therefore specifies the exact hopper, release mechanism and levelling procedure to remove this variable.
It correlates positively with milling yield and kernel soundness, so higher test weight generally means more flour per unit of grain. It does not capture protein quality or moisture, so it is used together with other tests rather than alone.
The falling number is the time in seconds for a stirrer to fall through a heated flour and water paste. A low value indicates high alpha-amylase activity and sprout damage, which reduces bread quality, while a high value indicates sound, un-sprouted grain.
The dielectric constant depends on grain structure and seed coat as well as water content, so wheat, maize, rice and oilseeds respond differently. Instruments therefore hold separate calibrations per species and often per variety group, and readings should be checked against an oven method.
With a calibration built for the local varieties and reference laboratory data, near-infrared protein predictions are typically within about 0.3 to 0.5 percent absolute of the reference method. Accuracy falls for varieties not represented in the calibration set.