NIR Crop and Feed Quality Analyzer
近红外作物和饲料品质分析仪
- SKU CRA-0001
- Crop Analysis
- CE (to be confirmed)
- RoHS (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Measurement principle | Near-infrared reflectance or transmission |
|---|---|
| Wavelength range | 850–2500 nm |
| Measured parameters | Protein, ADF, NDF, fat, starch, sugar, dry matter |
| Measurement time | 30–90 s |
| Sample preparation | Dried and ground, or fresh |
| Particle size | 1 mm sieve (ground) |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 2173 (soluble solids), ISO 5984 (crude ash), ISO 6496 (moisture, feeds)
What is the NIR Crop and Feed Quality Analyzer?
A near-infrared instrument that predicts protein, fibre, fat, starch and dry matter in forage, feed and crop samples. It is the right choice for feed mills, forage testing labs and breeders who need rapid multi-nutrient results.
What is the NIR Crop and Feed Quality Analyzer?
A near-infrared instrument that predicts protein, fibre, fat, starch and dry matter in forage, feed and crop samples. It is the right choice for feed mills, forage testing labs and breeders who need rapid multi-nutrient results.
Overview
The analyzer measures near-infrared reflectance or transmission from a prepared sample and applies calibration models to predict composition. Forage, hay and silage are usually dried and ground before measurement to a defined particle size, while some instruments accept fresh or unground material with appropriate calibrations. Protein, acid and neutral detergent fibre, fat, starch, sugar, ash and dry matter are common outputs. Models are developed from samples whose values were determined by wet chemistry such as Kjeldahl and fiber analysis, and they must cover the species and harvest conditions in use. Portable models suit field and silo sampling, and bench-top units give more stable conditions and better repeatability. Results guide ration formulation, forage marketing and breeding selection, and reduce the laboratory turnaround compared with wet chemistry.
How does it work?
Crop analysis uses several measurement principles. Penetrometers push a calibrated plunger into fruit flesh and record the peak force needed, giving a firmness index related to ripeness and storage life. Refractometers measure the refractive index of juice, which depends on dissolved solids, and report results as degrees Brix for sugars and total soluble solids. Colorimeters illuminate the surface and measure reflected light in defined colour spaces, so ripeness, sorting and defects can be assessed objectively. Near-infrared analyzers measure reflectance from ground forage or feed and predict protein, fibre, fat, starch and dry matter from calibration models. Moisture meters and microwave or halogen analyzers determine dry matter by loss on drying, which is important for silage and hay. Together these tools support harvest timing, grading, blending and quality control.
What are the key features?
- Predicts several nutrients from one measurement in under a minute.
- Portable and bench-top formats suit field or laboratory use.
- Calibrations built from wet chemistry cover common forage species.
- Fresh, dried or ground sample options match different workflows.
- Results exported for ration formulation and herd management systems.
- Sample library supports ongoing calibration improvement.
What are the technical specifications?
A typical nir crop and feed quality analyzer configuration offers measurement principle of Near-infrared reflectance or transmission, wavelength range of 850–2500 nm, measured parameters of Protein, ADF, NDF, fat, starch, sugar, dry matter, measurement time of 30–90 s, sample preparation of Dried and ground, or fresh and particle size of 1 mm sieve (ground). Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The NIR Crop and Feed Quality Analyzer is used in forage and silage quality testing, feed mill ingredient control, ration formulation support and forage breeding and variety trials. Across the wider Crop Analysis class, laboratories also deploy it for fruit and vegetable harvest timing, produce grading and packing lines and silage and hay dry matter management.
Which standards and certifications apply?
Relevant standards and methods include ISO 2173 (soluble solids), ISO 5984 (crude ash), ISO 6496 (moisture, feeds), ISO 6865 (crude fibre), UNECE FFV standards and AOAC 934.01. Certification candidates for this model are CE, RoHS and ISO 9001 manufacturing; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Follow the standard sampling and preparation procedure, because firmness, Brix and dry matter depend strongly on fruit temperature, sample position and time since harvest. Calibrate refractometers with distilled water and check them against a sucrose standard, and clean the prism carefully to avoid a cloudy reading. For penetrometers, standardise the plunger size, penetration speed and skin removal, and discard samples with visible defects. Keep near-infrared instruments clean and update forage and feed calibrations with local samples each season. For moisture and dry matter, control drying temperature and time exactly. Record sample origin, handling and instrument settings, and keep reference samples for traceability. Store and transport instruments so that optics, probes and batteries are protected.
How do I select the right NIR Crop and Feed Quality Analyzer?
Select the NIR analyzer when rapid multi-nutrient results are needed for feed management or breeding where local calibrations can be maintained. For legally reported reference values, wet chemistry is still required. In an RFQ, specify species, parameters, sample preparation and whether portable or bench-top operation is preferred.
How does it compare with other Crop Analysis variants?
Define the quality parameter that drives the decision before choosing an instrument. For ripeness and harvest timing in fruit, a penetrometer and a refractometer give direct, low-cost readings; select a plunger diameter and force range suited to the crop, since standards specify these. For objective grading and sorting, a colorimeter with the correct colour space and aperture avoids subjective judgement. For feed and forage value, a near-infrared analyzer predicts several nutrients at once but needs local calibrations from wet chemistry. For dry matter in silage and hay, choose a microwave or halogen analyzer with the sample preparation the standard requires. Consider portability for field use, calibration and reference sample support, and whether results must be exported to grading or quality systems.
Full specifications
| Measurement principle | Near-infrared reflectance or transmission |
|---|---|
| Wavelength range | 850–2500 nm |
| Measured parameters | Protein, ADF, NDF, fat, starch, sugar, dry matter |
| Measurement time | 30–90 s |
| Sample preparation | Dried and ground, or fresh |
| Particle size | 1 mm sieve (ground) |
| Calibration | Species-specific, wet chemistry based |
| Outputs | USB, Ethernet, LIMS export |
| Operating temperature | 5–40 °C |
| Power supply | Battery or 100–240 VAC |
| Weight | 3–15 kg |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Forage and silage quality testing
- Feed mill ingredient control
- Ration formulation support
- Forage breeding and variety trials
Key features
- Predicts several nutrients from one measurement in under a minute.
- Portable and bench-top formats suit field or laboratory use.
- Calibrations built from wet chemistry cover common forage species.
- Fresh, dried or ground sample options match different workflows.
- Results exported for ration formulation and herd management systems.
- Sample library supports ongoing calibration improvement.
Frequently asked questions about NIR Crop and Feed Quality Analyzer
Ground, dried samples give the most repeatable results because particle size and moisture are controlled, and they match the calibration conditions. Some instruments measure fresh or unground forage, but accuracy and repeatability are lower.
Add locally harvested samples each season, or whenever a new variety dominates, to keep models representative. Routine checks with reference samples and periodic wet chemistry comparisons confirm that predictions remain within acceptable error.
Calibrations are labelled as either acid detergent fibre and neutral detergent fibre or crude fibre, and the values are only comparable within the same method family. Users must confirm which convention their ration software or contract expects.
Brix is the concentration of dissolved solids in juice, mainly sugars, expressed in degrees, and it predicts sweetness, maturity and potential quality. It is measured by refractometry and is used widely in fruit, grape and sugar crop assessment.
A penetrometer presses a plunger of specified diameter into peeled flesh at a controlled speed and records the peak force in newtons or pounds. Firmness falls as fruit ripens, so the reading guides harvest date and predicts storage life.
Dry matter determines the feeding value and preservation of silage and hay. If it is too low, effluent and poor fermentation result; if too high, compaction and mould are problems. Growers use it to time cutting and to manage wilting.