Automatic Pensky-Martens Closed Cup Flash Point Tester
自动彭斯基-马丁斯闭口闪点测定仪
- SKU FPT-0002
- Flash Point Testers
- CE (to be confirmed)
- ISO 9001 manufacturing (to be confirmed)
- IEC 61010-1 electrical safety (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Test method | ASTM D93 Procedure A/B/C, ISO 2719 |
|---|---|
| Temperature range | Ambient to 400 °C |
| Temperature resolution | 0.1 °C |
| Temperature accuracy | ±0.5 °C typical |
| Heating rate | 1–6 °C/min programmable |
| Flash detection | Ionization or thermal sensor |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ASTM D93, ASTM D92, ASTM D56
What is the Automatic Pensky-Martens Closed Cup Flash Point Tester?
An automatic Pensky-Martens closed cup tester controls heating, stirring, ignition and flash detection electronically, and applies barometric correction to the result. It fits laboratories testing many fuel and lubricant samples under ASTM D93 or ISO 2719 that need repeatable, operator-independent results and stored records.
What is the Automatic Pensky-Martens Closed Cup Flash Point Tester?
An automatic Pensky-Martens closed cup tester controls heating, stirring, ignition and flash detection electronically, and applies barometric correction to the result. It fits laboratories testing many fuel and lubricant samples under ASTM D93 or ISO 2719 that need repeatable, operator-independent results and stored records.
Overview
The automatic version uses the same standard closed cup geometry as the manual instrument but automates the procedure. A microprocessor controls the heating ramp, drives the stirrer and performs ignition dips at the intervals specified by the method. Flash detection relies on an ionization ring or thermal sensor, so the operator no longer judges the flash visually. A built-in barometer supplies the pressure used to correct the result to 101.3 kPa. After the flash, the lid lifts and a cooling fan or forced-air system shortens the cool-down before the next sample. Results, method settings and calibration data are stored and can be printed or exported over USB or serial connections. Safety features include over-temperature cut-off and automatic flame-out detection. The added electronics raise the price and require sensor checks but improve consistency between operators.
How does it work?
A flash point tester heats a measured sample in a standard cup at a prescribed rate while stirring or not, depending on the method. At set temperature intervals an ignition source, either a gas flame or an electric igniter, is dipped into the vapor space above the liquid. The flash point is the lowest corrected temperature at which the vapors ignite with a distinct flash. Closed-cup designs confine vapors under a lid and give lower values, while open-cup designs expose the surface to air and give higher values. Main components are the test cup, heating block or bath, stirrer, shutter and igniter assembly, temperature probe and, in automatic models, a flash detector using ionization or thermal sensing. Barometric pressure is recorded because results are corrected to 101.3 kPa.
What are the key features?
- Microprocessor control of heating, stirring and ignition
- Ionization or thermal flash detection without visual judgment
- Built-in barometer with automatic pressure correction
- Forced-air cooling to shorten sample turnaround
- Result storage with USB or serial output
- Over-temperature and flame-out safety protection
What are the technical specifications?
A typical automatic pensky-martens closed cup flash point tester configuration offers test method of ASTM D93 Procedure A/B/C, ISO 2719, temperature range of Ambient to 400 °C, temperature resolution of 0.1 °C, temperature accuracy of ±0.5 °C typical, heating rate of 1–6 °C/min programmable and flash detection of Ionization or thermal sensor. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Automatic Pensky-Martens Closed Cup Flash Point Tester is used in refinery quality control, independent inspection laboratories, lubricant blending plants and biodiesel blend testing. Across the wider Flash Point Testers class, laboratories also deploy it for refinery product release, lubricant and base oil QC and hazardous goods classification.
Which standards and certifications apply?
Relevant standards and methods include ASTM D93, ASTM D92, ASTM D56, ASTM D3828, ISO 2719, ISO 2592, IP 34, GB/T 261 and IEC 61010-1. Certification candidates for this model are CE, ISO 9001 manufacturing and IEC 61010-1 electrical safety; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Place the tester in a draft-free area, because air movement disturbs vapor concentration and shifts results. Connect a fume extraction hood and keep flammable samples away from the heating block. Verify the temperature probe and, where applicable, the barometer against traceable references at least annually. Check instrument performance regularly with certified reference fluids such as n-decane or n-hexadecane and compare results with stated tolerances. Clean the cup, lid and igniter after each test to prevent carbon build-up. Replace gas supply hoses on schedule, and confirm flame-out detection works. Record the ambient pressure with each result. Operators should be trained on sample handling, because losing volatile fractions before the test lowers apparent flammability risk.
How do I select the right Automatic Pensky-Martens Closed Cup Flash Point Tester?
Choose the automatic model when you test more than several samples per day, need records for audits, or want to reduce operator bias. Compared with the manual model it costs more but saves labor. In an RFQ specify the methods required, temperature range, sample cooling needs, data export format, and calibration documentation.
How does it compare with other Flash Point Testers variants?
Select first by the method your specification cites, since cup geometry, heating rate and stirring differ between Pensky-Martens, Cleveland, Tag and small-scale procedures. Closed-cup methods suit fuels, solvents and most regulatory classification. Open-cup methods suit viscous lubricants, bitumen and products whose fire point is also required. Next consider throughput and operator dependence: manual testers are economical for occasional use, while automatic models control the heating ramp, detect the flash electronically and apply barometric correction. Check the temperature range against your products, including whether you need cooling for sub-ambient samples. Small-scale testers save sample and time for screening but may not be accepted as a referee method. Confirm fume extraction, flame-safety shutoff and available calibration reference fluids.
Full specifications
| Test method | ASTM D93 Procedure A/B/C, ISO 2719 |
|---|---|
| Temperature range | Ambient to 400 °C |
| Temperature resolution | 0.1 °C |
| Temperature accuracy | ±0.5 °C typical |
| Heating rate | 1–6 °C/min programmable |
| Flash detection | Ionization or thermal sensor |
| Sample volume | About 75 mL |
| Display | Color touchscreen |
| Data output | USB, RS232, printer |
| Power supply | 220 V, 50 Hz, 700 W |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Refinery quality control
- Independent inspection laboratories
- Lubricant blending plants
- Biodiesel blend testing
Key features
- Microprocessor control of heating, stirring and ignition
- Ionization or thermal flash detection without visual judgment
- Built-in barometer with automatic pressure correction
- Forced-air cooling to shorten sample turnaround
- Result storage with USB or serial output
- Over-temperature and flame-out safety protection
Frequently asked questions about Automatic Pensky-Martens Closed Cup Flash Point Tester
An ionization ring or thermal sensor in the vapor space detects the sudden current or temperature rise when vapors ignite. The controller records the temperature at that moment as the flash point. This removes the subjectivity of visually judging the flash.
Most automatic models store test records internally with date, method, sample ID and corrected result, and export them by USB, serial output or printer. If you need audit trails or LIMS integration, specify this in the RFQ so the supplier can confirm software features.
Time depends on the expected flash point and heating rate. A diesel sample at about 60 °C typically takes 15 to 30 minutes including heating, plus cool-down time before the next sample. Forced-air cooling shortens turnaround compared with natural cooling.
Closed-cup testers confine vapors under a lid, so they reach ignitable concentration at lower temperature and give lower, more conservative values. Open-cup testers expose the liquid surface to air and give higher values. Regulations and product specifications state which method applies to each product type.
Diesel fuel flash point is usually determined by ASTM D93 using the Pensky-Martens closed cup, which ISO 2719 mirrors. Jet fuel often uses D56 Tag or D3828 small-scale methods instead. Check your product specification, such as ASTM D975, for the required method and minimum flash point.
Flash point varies with atmospheric pressure, because vapor-air ignition depends on partial pressure. Methods such as ASTM D93 require correcting the observed value to standard pressure of 101.3 kPa. Automatic testers often include a built-in barometer and apply the correction to the reported result.