

Fluorescence Immunoassay Analyzer
荧光免疫分析仪
- SKU FLI-0001
- Fluorescence Immunoassay
- CE (to be confirmed)
- ISO 13485 manufacturing (to be confirmed)
- NMPA class II registration (to be confirmed)
Price on request — FOB / CIF quoted per order
Prices depend on configuration, quantity and destination port.
Key specifications
| Excitation wavelength | 470–610 nm depending on the label |
|---|---|
| Emission wavelength | 520–670 nm with bandpass filter |
| Measuring range | Assay specific, typically 3 orders of magnitude |
| Sample volume | 10–100 µL |
| Time to result | 10–20 min |
| Throughput | 20–60 tests/h |
By Lab Manufacturers China Technical TeamLast reviewed Standards: ISO 15189, CLSI EP05, CLSI EP15
What is the Fluorescence Immunoassay Analyzer?
A fluorescence immunoassay analyzer measures the emission from fluorescently labelled immune complexes to quantify analytes such as cardiac markers, hormones and inflammation proteins. It suits clinics and emergency departments that need quantitative results in about fifteen minutes from a small sample.
What is the Fluorescence Immunoassay Analyzer?
A fluorescence immunoassay analyzer measures the emission from fluorescently labelled immune complexes to quantify analytes such as cardiac markers, hormones and inflammation proteins. It suits clinics and emergency departments that need quantitative results in about fifteen minutes from a small sample.
Overview
The analyzer excites the fluorophore with a light source such as an LED, separates emission from excitation with optical filters and measures the signal with a photodiode or photomultiplier. Many platforms accept single-test cartridges containing dried reagents and a test strip, so the operator adds a measured volume of sample and the instrument performs the reaction and reading. Calibration data travel with the cartridge barcode, which means the analyzer applies the correct curve for the lot without manual programming. Typical throughput is twenty to sixty tests per hour, sample volume is ten to one hundred microliters, and results appear in ten to twenty minutes. Quality features include automatic control checks, result flags for out-of-range values and interfaces for transmitting results to a laboratory information system.
How does it work?
Fluorescence immunoassay uses an antibody labelled with a fluorophore such as fluorescein, a europium chelate or a quantum dot. After the immune complex forms, the label is excited by light of one wavelength and emits light at a longer wavelength, and a photodetector measures the emission after optical filtering. The difference between excitation and emission wavelengths allows the instrument to separate the signal from the excitation light, and background fluorescence from sample components is reduced by careful filter selection, by washing away unbound label and, in time-resolved systems, by delaying the measurement until short-lived background fluorescence has decayed. Since the fluorescent signal is measured against a low background, sensitivity is generally better than absorbance-based enzyme immunoassay. Quantification relies on a calibration curve stored in the analyzer, and strip-based tests use a reader that scans the test and control lines.
What are the key features?
- LED excitation with filtered emission detection
- Single-test cartridges with barcode-calibrated curves
- Results in ten to twenty minutes from a small sample
- Onboard control data storage and out-of-range flags
- Touchscreen operation with minimal training requirement
- LIS interface for result transmission
What are the technical specifications?
A typical fluorescence immunoassay analyzer configuration offers excitation wavelength of 470–610 nm depending on the label, emission wavelength of 520–670 nm with bandpass filter, measuring range of Assay specific, typically 3 orders of magnitude, sample volume of 10–100 µL, time to result of 10–20 min and throughput of 20–60 tests/h. Values are indicative of the product class; the exact figures for each configuration are confirmed on the quotation and the calibration documents supplied with the instrument.
Which applications is it used for?
The Fluorescence Immunoassay Analyzer is used in emergency cardiac marker testing, inflammation marker testing in clinics, fertility and pregnancy hormone testing and infectious disease antigen detection. Across the wider Fluorescence Immunoassay class, laboratories also deploy it for point-of-care cardiac and inflammation testing, hormone and fertility testing in clinics and infectious disease antigen detection.
Which standards and certifications apply?
Relevant standards and methods include ISO 15189, CLSI EP05, CLSI EP15, CLSI EP17, CLSI POCT04, IEC 61010-1 and IEC 61010-2-101. Certification candidates for this model are CE, ISO 13485 manufacturing and NMPA class II registration; each is to be confirmed for the specific configuration before shipment, and certificates are supplied only where they have been issued.
Keep the instrument away from strong ambient light and place it on a stable bench, because stray light and vibration reduce fluorescence measurement precision. Verify performance at installation with the manufacturer's calibration material and with controls at two or three levels, and check the optical path and detector gain as specified. Daily tasks include control measurement and checking that the correct assay lot and curve are selected. Lateral flow readers require consistent sample application volume, controlled reading time after the reaction and careful handling of cartridges, since a delay of a few minutes can change the result near a cut-off. Store cartridges and reagents within their temperature range, use them before expiry, and treat all used devices as infectious waste.
How do I select the right Fluorescence Immunoassay Analyzer?
Specify this variant when rapid quantitative results are needed where the patient is seen, and when the assay menu covers your clinical focus. In the RFQ confirm the registration of each cartridge assay, the time to result, sample type acceptance including whole blood, the calibration mechanism, and the supply and shelf life of cartridges.
How does it compare with other Fluorescence Immunoassay variants?
Choose the format from the clinical setting: a strip or cartridge reader suits single tests at the point of care, while a plate or automated platform suits batch testing in a laboratory. Then check the assay menu and its regulatory status, because fluorescence platforms are kit specific and an instrument without the tests you need has no value. Compare sensitivity at the clinical decision point, measuring range, sample volume and time to result, which ranges from ten minutes for lateral flow to several hours for batch formats. For quantitative work, confirm that the analyzer stores calibration curves per lot and applies them automatically by reading a cartridge barcode. Consider whether fluorescence interference from bilirubin, haemoglobin or medication is documented for each assay, and whether controls and calibration material are available locally.
Full specifications
| Excitation wavelength | 470–610 nm depending on the label |
|---|---|
| Emission wavelength | 520–670 nm with bandpass filter |
| Measuring range | Assay specific, typically 3 orders of magnitude |
| Sample volume | 10–100 µL |
| Time to result | 10–20 min |
| Throughput | 20–60 tests/h |
| Calibration | Lot-specific curve stored in cartridge barcode or reader |
| Data storage | 10,000 patient results with control records |
| Interfaces | LAN, USB, RS-232 with LIS option |
Indicative values for this product class. Final specifications are confirmed on the quotation and in the calibration documents supplied with the instrument.
Applications
- Emergency cardiac marker testing
- Inflammation marker testing in clinics
- Fertility and pregnancy hormone testing
- Infectious disease antigen detection
Key features
- LED excitation with filtered emission detection
- Single-test cartridges with barcode-calibrated curves
- Results in ten to twenty minutes from a small sample
- Onboard control data storage and out-of-range flags
- Touchscreen operation with minimal training requirement
- LIS interface for result transmission
Frequently asked questions about Fluorescence Immunoassay Analyzer
Many cartridges accept whole blood from a finger stick or a lithium heparin tube, which shortens turnaround because no centrifugation is needed. Confirm the accepted anticoagulant and hematocrit range for each assay, since whole blood performance can differ from serum or plasma.
Most cartridge systems store the lot-specific curve in a barcode or a chip on the cartridge, so the analyzer reads and applies it automatically. Laboratories should verify the curve with control samples when a new lot is introduced and record the lot number with the results.
Coefficients of variation of five to ten percent are typical across the measuring range, which is adequate for most clinical decisions but higher than laboratory immunoassay platforms. Laboratories should establish acceptance criteria for duplicates and for comparison with an established method.
It does not need a dark room, because the optics are enclosed inside the instrument, but strong direct light on the cartridge slot and vibration can still disturb readings. Keep the analyzer out of direct sunlight and on a stable bench, and do not open the cartridge door during a run.
Fluorescent labels emit against a low background, so assays can detect lower concentrations than absorbance-based methods and often cover a wider measuring range. The trade-off is greater sensitivity to interference from sample fluorescence and to variations in optical alignment, which is why controls matter.
Time-resolved systems use lanthanide chelates with a long fluorescence lifetime, and the instrument waits a short interval after excitation before measuring. Short-lived background fluorescence from serum components decays during that delay, so the measured signal contains less interference and allows lower detection limits.
Yes, quantitative readers scan the intensity of the test line and compare it with a stored calibration curve, provided the sample volume and reading time are controlled. Precision is lower than laboratory platforms, so quantitative strip tests are usually validated against a laboratory method before clinical use.
Related models






